BS 8303-3-1995 Installation of domestic heating and cooking appliances burning solid mineral fuels - Recommendations for design and on site installation《燃烧固体燃料的家用采暖设备和灶具的安装 设计与现场安装.pdf
《BS 8303-3-1995 Installation of domestic heating and cooking appliances burning solid mineral fuels - Recommendations for design and on site installation《燃烧固体燃料的家用采暖设备和灶具的安装 设计与现场安装.pdf》由会员分享,可在线阅读,更多相关《BS 8303-3-1995 Installation of domestic heating and cooking appliances burning solid mineral fuels - Recommendations for design and on site installation《燃烧固体燃料的家用采暖设备和灶具的安装 设计与现场安装.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS8303-3: 1994 Installation of domestic heating and cooking appliances burning solid mineral fuels Part 3: Recommendations for design and on site installation IMPORTANT NOTE. Before reading this Part it is essential to read BS8303-1: Specification for the design of installations and
2、 BS 8303-2: Specification for installing and commissioning on-site, issued separately.BS8303-3:1994 This British Standard, having been prepared under the directionof the Engineering SectorBoard, was published underthe authority of the Standards Board and comes intoeffect on 15 January 1995 BSI 02-19
3、99 First published, as CP403, August1952 Second edition, October 1974 Third edition, as BS8303, June1986 Fourth edition, January 1995 The following BSI references relate to the work on this standard: Committee reference RHE/28 Draft for comment 91/82857 DC ISBN 0 580 22713 8 Committees responsible f
4、or this British Standard The preparation of this British Standard was entrusted by the Engineering Sector Board to Technical Committee RHE/28, upon which the following bodies were represented: Association of British Solid Fuel Appliance Manufacturers British Ceramic Tile Council British Coal Corpora
5、tion Consumer Policy Committee of BSI Department of Energy (Energy Efficiency Office) Department of the Environment HETAS Ltd. Incorporated Association of Architects and Surveyors Low Temperature Coal Distillers of Great Britain Ltd. METCOM National Fireplace Manufacturers Association National Socie
6、ty for Clean Air Real Fire Association Solid Smokeless Fuels Federation Waterheater Manufacturers Association Coopted members Amendments issued since publication Amd. No. Date CommentsBS8303-3:1994 BSI 02-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Definiti
7、ons 1 3 References 1 4 Chimney connection for free standing appliances 1 5 Securing an appliance 1 6 Air inlets 1 7 Sealing of joints 2 8 Flue size 3 9 Separation from combustible material 3 10 Noise 8 11 Energy economy and heat retention 8 12 Alternative flue pipe construction 8 13 Gas ignition 9 1
8、4 Firebacks and infill 9 15 Testing an installation 9 Figure 1 Typical flue connection of a freestanding cooker or independent boiler 2 Figure 2 Dimensions of a fireplace recess 4 Figure 3 Dimensions of a constructional hearth 5 Figure 4 Combustible material under hearth 5 Figure 5 Positioning of ap
9、pliance on a hearth 6 Figure 6 Distance of an appliance from combustible material 6 Figure 7 Separation of a flue pipe from combustible material 7 Table 1 Composition proportions for in-fill 9 List of references Inside back coverBS8303-3:1994 ii BSI 02-1999 Foreword This Part of BS8303 has been prep
10、ared under the direction of the Engineering Sector Board and together with BS8303-1 and BS8303-2 supersedes BS8303:1986 which is withdrawn. BS8303 covers the installation of domestic heating and cooking appliances burning solid mineral fuel. BS8303-1 details the design specification to be followed b
11、y the installation designer, when developing an acceptable appliance installation design for the particular application. BS8303 specifies the practices to be followed when installing the appliance in accordance with the design specification. It reflects good site supervision and working practices. T
12、his Part of BS8303 gives guidance to the designer and installer on options to be identified and the methods of achieving a safe and satisfactory installation. BS8303 does not deal with design or installation of hot water heating systems or hot water supply systems. However, where the appliance invol
13、ves hot water services, attention is drawn to BS5449:1990. Attention is drawn to the need to ensure compliance with all local and general regulations as they affect the installation, including the following: A British Standard does not purport to include all the necessary provisions of a contract. U
14、sers of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. planning permission; Building Regulations 1; Clean Air Act 2; Gas Safety (Installation and Use) Regulations 3. Summary of pages This
15、document comprises a front cover, an inside front cover, pages i and ii, pages1to 10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on theinside front cover.BS8303-3:1
16、994 BSI 02-1999 1 1 Scope This Part of BS8303 gives guidance and recommendations on the design and installation of domestic heating and cooking appliances burning solid mineral fuels designed in accordance with BS8303-1:1994 and installed in accordance with BS8303-2:1994. 2 Definitions For the purpo
17、ses of this Part of BS8303, the definitions given in BS1846-1:1994 apply. 3 References 3.1 Normative references This Part of BS8303 incorporates, by dated or undated reference, provisions from other publications. These normative references are made at the appropriate places in the text and the cited
18、 publications are listed on the inside back cover. For dated references, only the edition cited applies; any subsequent amendments to or revisions of the cited publication apply to this Part of BS8303 only when incorporated in it by amendment or revision. For undated references, the latest edition a
19、pplies, together with any amendments. 3.2 Informative references This Part of BS8303 refers to other publications that provide information or guidance. Editions of these publications current at the time of issue of this standard are listed on the inside back cover, but reference should be made to th
20、e latest editions. 4 Chimney connection for free standing appliances Where a freestanding appliance is to be installed without the use of a fireplace recess no part of the chimney should be supported by the appliance. This is neccessary so that if an appliance needs to be removed for any reason it c
21、an be achieved without major disturbance to the chimney. Masonry chimneys can be built up from ground level, a fireplace recess or part of the wall structure of the building. The connection between the appliance and the chimney is achieved via a flue pipe entry either vertically from underneath Figu
22、re 1a) or into an opening in the side of the flue Figure 1b) or Figure 1c). A factory made chimney is commonly supported on ceiling joists. In this case care should be taken that the length of chimney below the lowest support is correctly secured to the section above it and not allowed to rest on th
23、e appliance or any flue pipe. 5 Securing an appliance The appliance should be secured to prevent movement which could cause joint separation at the flue pipe or chimney connection, and for open fires, at the hearth and fire surround. Joint separation could result in leakage of air into the flue or a
24、llow combustion products to escape into the building. Securing is particularly important where an appliance relies for its connection to the flue on a seal between the appliance and the fireplace recess to prevent any leakage. Movement of the appliance can occur for a variety of reasons such as vigo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS830331995INSTALLATIONOFDOMESTICHEATINGANDCOOKINGAPPLIANCESBURNINGSOLIDMINERALFUELSRECOMMENDATIONSFORDESIGNANDONSITEINSTALLATION

链接地址:http://www.mydoc123.com/p-547325.html