BS 7870-8 6-2003 LV and MV polymeric insulated cables for use by distribution and generation utilities - Specification for multicore and multipair cables for installation above and.pdf
《BS 7870-8 6-2003 LV and MV polymeric insulated cables for use by distribution and generation utilities - Specification for multicore and multipair cables for installation above and.pdf》由会员分享,可在线阅读,更多相关《BS 7870-8 6-2003 LV and MV polymeric insulated cables for use by distribution and generation utilities - Specification for multicore and multipair cables for installation above and.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 7870-8.6:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities Part 8: Specification for multicore and multipair cables for installation above and below ground Section 8.6: Single wire or double steel tape armoured and non-halogenated sheathed
2、 multipair cable with copper conductors (Implementation of part of HD 627) ICS 29.060.20 BS 7870-8.6:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 16 June 2003 BSI 16 June 2003 The following BSI references relate to the work on this Br
3、itish Standard: Committee reference GEL/20/16 Draft for comment 99/244662 DC ISBN 0 580 37572 2 Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee GEL/20, Cables, to Subcommittee GEL/20/16, Medium/high voltage cables, upon w
4、hich the following bodies were represented: British Approval Service for Cables British Cables Association British Plastics Association Electricity Association ERA Technology Co-opted members Amendments issued since publication Amd. No. Date CommentsBS 7870-8.6:2003 BSI 16 June 2003 i Contents Page
5、Committees responsible Inside front cover Foreword ii 1S c o p e 1 2 Normative references 1 3 Rated voltage 2 4C o n d u c t o r s 2 5 Insulation 2 6 Identification of cores 2 7 Assembly of cores, fillers and binders 4 8 Rip cord 4 9 Collective screen 4 10 Bedding layer 4 11 Armouring 4 12 Oversheat
6、h 4 13 Marking 5 14 Dimensions 6 15 Tests 8 16 Routine tests 9 17 Sample tests 10 18 Type tests 12 Annex A (informative) Guide to use 20 Bibliography 23 Table 1 Colour codes 3 Table 2 Multipair cables (Type 1) 7 Table 3 Multipair cables (Type 2) 7 Table 4 Schedule of tests 8 Table 5 Diameter of armo
7、ur wire 11 Table 6 Type approval tests 12 Table 7 Mass of zinc coating 13 Table 8 Requirements for non-electrical tests on polyethylene 13 Table 9 Requirements for non-electrical tests on aromatic compound 14 Table 10 Requirements for non-electrical tests for non-halogenated bedding and oversheath 1
8、5 Table 11 Special type tests for Type 2 cables 18BS 7870-8.6:2003 ii BSI 16 June 2003 Foreword This section of BS 7870 has been prepared by Subcommittee GEL/20/16, under the direction of Technical Committee GEL/20. BS 7870 implements the nationally applicable parts of Harmonization Documents HD 603
9、, HD 604, HD 605, HD 620, HD 622, HD 626 and HD 627 published by the European Committee for Electrotechnical Standardization (CENELEC) in accordance with the decision of the CENELEC Technical Board. BS 7870 applies to cables for fixed installations having a rated voltage U 0 /U up to and including 1
10、9/33 kV, and is published as a series of separate parts and sections, as listed in the table in the foreword of BS 7870-1. BS 7870-8.6 implements HD 627:Part 7A2 and is to be read in conjunction with BS 7870-1 and BS 7870-2. It has been assumed in the preparation of this British Standard that the ex
11、ecution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. WARNING This British Standard calls for procedures that may be injurious to health if adequate precautions are not taken. It refers only to technical suitability and doe
12、s not absolve the user from legal obligations relating to health and safety at any stage. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity
13、from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 23 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.BS 7870-8.6:2003 BSI 16 June 2003 1 1 Scope This sect
14、ion of BS 7870 specifies requirements for the construction, dimensions and mechanical and physical properties of multipair cables with halogen-free insulation and sheaths, having reduced fire propagation performance and low emission of smoke when affected by fire. It specifies requirements for multi
15、pair cables (up to 200-pair) with copper conductors, a collective screen and armouring consisting of a single layer of steel wires or a double layer of steel tapes. It specifies requirements for both Type 1 and Type 2 cables, which are defined as follows: Type 1: cable designed for the installation
16、and operating conditions prevailing in a conventional fossil fuelled power station or equivalent location; Type 2: cable designed for the installation and operating conditions prevailing in a PWR power station, but excluding location in or around the containment area. The requirements specified in t
17、his section of BS 7870 are applicable to both Type 1 and Type 2 cables unless otherwise indicated. This section of BS 7870 is applicable to cables for use in and around power stations and other installations having similar cable densities. NOTE A “guide to use” is given in Annex A. 2 Normative refer
18、ences The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. BS 6360, Specification for conductors in in
19、sulated cables and cords. BS 7870-1, LV and MV polymeric insulated cables for use by distribution and generation utilities Part 1: General. BS 7870-2:1999, LV and MV polymeric insulated cables for use by distribution and generation utilities Part 2: Methods of test. BS EN 50265-2-1:1999, Common test
20、 methods for cables under fire conditions Test for resistance to vertical flame propagation for a single insulated conductor or cable Part 2-1: Procedures 1 kW pre-mixed flame. BS EN 50265-2-2:1999, Common test methods for cables under fire conditions Test for resistance to vertical flame propagatio
21、n for a single insulated conductor or cable Part 2-2: Procedures Diffusion flame. BS EN 50267-2-1, Common test methods for cables under fire conditions Tests on gases evolved during combustion of materials from cables Part 2-1: Procedures Determination of amount of halogen gas. BS EN 50268-2:2000, C
22、ommon test methods for cables under fire conditions Measurement of smoke density of cables burning under defined conditions Part 2: Procedure. BS EN 60811-1-1:1995, Insulating and sheathing materials of electric cables Common test methods Part 1-1: General application Measurement of thickness and ov
23、erall dimensions Tests for determining the mechanical properties. BS EN 60811-1-2:1995, Insulating and sheathing materials of electric cables Common test methods Part 1-2: General application Thermal ageing methods. BS EN 60811-1-3:1995, Insulating and sheathing materials of electric cables Common t
24、est methods Part 1-3: General application Methods for determining the density Water absorption tests Shrinkage test. BS EN 60811-1-4:1995, Insulating and sheathing materials for electric cables Common test methods Part 1-4: General application Test at low temperatures. BS EN 60811-2-1:1995, Insulati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS7870862003LVANDMVPOLYMERICINSULATEDCABLESFORUSEBYDISTRIBUTIONANDGENERATIONUTILITIESSPECIFICATIONFORMULTICOREANDMULTIPAIRCABLESFORINSTALLATIONABOVEANDPDF

链接地址:http://www.mydoc123.com/p-547125.html