《BS 7870-8 2-2003 LV and MV polymeric insulated cables for use by distribution and generation utilities - Specification for multicore and multipair cables for installation above and.pdf》由会员分享,可在线阅读,更多相关《BS 7870-8 2-2003 LV and MV polymeric insulated cables for use by distribution and generation utilities - Specification for multicore and multipair cables for installation above and.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 7870-8.2:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities Part 8: Specification for multicore and multipair cables for installation above and below ground Section 8.2: Single wire armoured and PVC sheathed multipair cable with copper cond
2、uctors (Implementation of part of HD 627) ICS 29.060.20 BS 7870-8.2:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 16 June 2003 BSI 16 June 2003 The following BSI references relate to the work on this British Standard: Committee referen
3、ce GEL/20/16 Draft for comment 99/244662 DC ISBN 0 580 37568 4 Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee GEL/20, Cables, to Subcommittee GEL/20/16, Medium/high voltage cables, upon which the following bodies were re
4、presented: British Approval Service for Cables British Cables Association British Plastics Association Electricity Association ERA Technology Co-opted members Amendments issued since publication Amd. No. Date CommentsBS 7870-8.2:2003 BSI 16 June 2003 i Contents Page Committees responsible Inside fro
5、nt cover Foreword ii 1S c o p e 1 2 Normative references 1 3 Rated voltage 1 4C o n d u c t o r s 1 5 Insulation 1 6 Identification of pairs 2 7 Assembly of pairs, fillers and binders 3 8 Bedding layer 3 9A r m o u r i n g 3 10 Oversheath 3 11 Marking 4 12 Dimensions 5 13 Tests 8 14 Routine tests 8
6、15 Sample tests 9 16 Type tests 11 Annex A (informative) Guide to use 14 Annex B (normative) Compatibility of filling materials 16 Annex C (normative) Water penetration test 17 Bibliography 19 Figure C.1 Water penetration test arrangement 17 Table 1 Multipair cables with steel wire armouring where i
7、nduced voltage does not exceed 5 kV 6 Table 2 Multipair cables with steel wire armouring where induced voltage does not exceed 15 kV 6 Table 3 Polyethylene-insulated, multipair cables for use where the induced voltage would otherwise exceed 15 kV (aluminium wire armoured) 7 Table 4 Schedule of tests
8、 8 Table 5 Group insulation resistance 9 Table 6 Diameter of armour wire 11 Table 7 Requirements for non-electrical tests on polyethylene 12 Table 8 Mass of zinc coating 12 Table 9 Requirements for capacitance 13BS 7870-8.2:2003 ii BSI 16 June 2003 Foreword This section of BS 7870 has been prepared
9、by Subcommittee GEL/20/16, under the direction of Technical Committee GEL/20. BS 7870 implements the nationally applicable parts of Harmonization Documents HD 603, HD 604, HD 605, HD 620, HD 622, HD 626 and HD 627 published by the European Committee for Electrotechnical Standardization (CENELEC) in
10、accordance with the decision of the CENELEC Technical Board. BS 7870 applies to cables for fixed installations having a rated voltage U 0 /U up to and including 19/33 kV, and is published as a series of separate parts and sections, as listed in the table in the foreword of BS 7870-1. BS 7870-8.2 imp
11、lements HD 627-3A2 and is to be read in conjunction with BS 7870-1 and BS 7870-2. It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. WARNING. Thi
12、s British Standard calls for procedures that may be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not absolve the user from legal obligations relating to health and safety at any stage. This publication does not purport to include all the
13、 necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 19 and a bac
14、k cover. The BSI copyright notice displayed in this document indicates when the document was last issued.BS 7870-8.2:2003 BSI 16 June 2003 1 1 Scope This section of BS 7870 specifies requirements for the construction, dimensions and mechanical and physical properties of multipair polyethylene insula
15、ted, PVC sheathed cables. It specifies requirements for multipair cables (4 pairs to 61 pairs) having copper conductors with filled and unfilled interstices, normal and increased insulation and bedding thicknesses and either steel or aluminium wire armour. This section of BS 7870 is applicable to ca
16、bles for use underground in wet conditions and also for withstanding high levels of induced voltage. NOTE A “guide to use” is given in Annex A. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cit
17、ed applies. For undated references, the latest edition of the referenced document (including any amendments) applies. BS 6360, Specification for conductors in insulated cables and cords. BS EN 60811-4-2:2000, Insulating and sheathing materials of electric and optical fibre cables Common test methods
18、 Part 4-2: Methods specific to polyethylene and polypropylene compounds Tensile strength and elongation at break after pre-conditioning Wrapping test after thermal ageing in air Measurement of mass increase Long-term stability test Test method for copper-catalysed oxidative degradation. BS 7655-4.1,
19、 Specification for insulating and sheathing materials for cables Part 4: PVC sheathing compounds Section 4.1: Harmonized types. BS 7870-1, LV and MV polymeric insulated cables for use by distribution and generation utilities Part 1:General. BS 7870-2:1999, LV and MV polymeric insulated cables for us
20、e by distribution and generation utilities Part 2: Methods of test. BS EN 60811-1-1:1995, Insulating and sheathing materials of electric cables Common test methods Part 1-1: General application Measurement of thickness and overall dimensions Tests for determining the mechanical properties. BS EN 608
21、11-1-3:1995, Insulating and sheathing materials of electric cables Common test methods Part 1-3: General application Methods for determining the density Water absorption tests Shrinkage test. BS EN 60811-4-1:1995, Insulating and sheathing materials for electric cables Common test methods Part 4-1: M
22、ethods specific to polyethylene and polypropylene compounds Resistance to environmental stress cracking Wrapping test after thermal ageing in air Measurement of the flow index Carbon black and/or mineral content measurement in PE. IEC 60189-1:1986, Low-frequency cables and wires with p.v.c. insulati
23、on and p.v.c. sheath Part 1: General test and measuring methods. 3 Rated voltage The rated voltage of cables in this standard is 100 V a.c. or 150 V d.c. 4 Conductors Conductors shall be of plain copper wire consisting of a single strand of 0.8 mm nominal diameter, conforming to the requirements of
24、BS 6360. Conformity shall be checked by visual examination as specified in 15.2. 5 Insulation The insulation shall be polyethylene type TI Y conforming to the requirements specified in Table 7. The insulation shall be applied so that it fits closely on the conductor and it shall be possible to remov
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS7870822003LVANDMVPOLYMERICINSULATEDCABLESFORUSEBYDISTRIBUTIONANDGENERATIONUTILITIESSPECIFICATIONFORMULTICOREANDMULTIPAIRCABLESFORINSTALLATIONABOVEANDPDF

链接地址:http://www.mydoc123.com/p-547121.html