1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS 7797 : 1998 ICS 91.140
2、.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Specification for Industrial duct heaters using metal-sheathed elementsThis British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards B
3、oard and comes into effect on 15 May 1998 BSI 1998 The following BSI references relate to the work on this standard: Committee reference PEL/27 Draft for comment 92/04452 DC ISBN 0 580 29535 4 BS 7797 : 1998 Amendments issued since publication Amd. No. Date Text affected Committees responsible for t
4、his British Standard The preparation of this British Standard was entrusted to Technical Committee PEL/27, Electroheating, upon which the following bodies were represented: Association of Manufacturers Allied to the Electrical and Electronic Industry (BEAMA Ltd.) British Glass Manufacturers Confeder
5、ation British Industrial Furnace Constructors Association British Lighting Association for the Preparation of Standards (BRITLAPS) British National Committee for Electroheat British Steel plc Committee for Electrical Equipment for Use in Flammable Atmosphere (BEAMA Ltd.) Electric Trace Heating Indus
6、try Council (ETHIC) Electricity Association Energy Industries Council Engineering Equipment and Materials Users Association Engineering Industries Association Health and Safety Executive Induction and Dielectric Heating Manufacturers Association Institution of Electrical Engineers Lighting Industry
7、Federation Ltd.BS 7797 : 1998 BSI 1998 i Contents Page Committees responsible Inside front cover Foreword ii Specification 1 Scope 1 2 References 1 3 Definitions 1 4 Heating elements 2 5 Rating 2 6 Degree of protection 2 7 Electrical insulation 2 8 Thermal insulation 2 9 Construction 3 10 Supply con
8、nections 3 11 Terminations for external conductors 4 12 Provision for earthing 6 13 Internal wiring 7 14 Mounting of components 8 15 Screws and connections 8 16 Creepage distances, clearances, and distances through insulation 9 17 Controls 10 18 Labels and warning notices 10 19 Routine testing 10 20
9、 Instructions 11 21 Marking 11 Annexes A (normative) Methods of test 12 B (informative) Guidance for installation and maintenance of duct heaters 13 Tables 1 Power output 2 2 Minimum thickness of metallic enclosures 3 3 Terminal sizes 4 4 Fastening strength of terminals 4 5 Dimensions of pillar term
10、inals 5 6 Dimensions of screw terminals 6 7 Dimensions of stud terminals 6 8 Minimum spacings 8 9 Creepage distances and clearances 9 10 Temperature marking for supply connections 10 11 Symbols for marking 11 A.1 Torque values for screw torque test 12 A.2 Torque values for screw torque test, for ter
11、minals described in 11.2.3 and 11.3.3 13 List of references Inside back coverii BSI 1998 BS 7797 : 1998 Foreword This British Standard has been prepared by Technical Committee PEL/27. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standard
12、s are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 14, an inside back cover and a back cover. BSI 1998
13、 1 BS 7797 : 1998 Specification 1 Scope This British Standard specifies requirements for industrial electric heaters with a rated voltage of up to 440 V, using metal-sheathed elements and installed in a duct run, for heating in forced air systems or for heating of non-flammable gases. The heaters ma
14、y have fixed, replaceable or removable elements. 2 Normative references This British Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are made at the appropriate places in the text and the cited publications are listed on the inside
15、 back cover. For dated references, only the edition cited applies: any subsequent amendments to or revisions of the cited publication apply to this British Standard only when incorporated in the reference by amendment or revision. For undated references, the latest edition of the cited publication a
16、pplies, together with any amendments. 3 Definitions For the purposes of this British Standard, the following definitions apply. 3.1 (metal-sheathed heating) element A heating assembly comprising a resistance alloy within, and insulated from, a tubular metal sheath. 3.2 duct heater An assembly of met
17、al-sheathed heating element(s), associated controls and wiring, installed in a duct run. 3.3 terminal enclosure The enclosure in which the elements are terminated. NOTE. Other electrical equipment can be contained within the enclosure; for example, thermostats, pressure switches, contactors, transfo
18、rmers, fuses. 3.4 fixed element An element which is permanently attached to its supporting body by adhesive bonding, soldering, brazing or welding. 3.5 replaceable element An element which can only be removed with the aid of a tool, normally after removal of the element bundle from its containment d
19、ucting. 3.6 removable element An element which can be removed without the need for removing the element bundle from its containment ducting. 3.7 ducting The sheet-metal fabrication through which the air or non-flammable gases pass, and into which the element bundle is inserted. 3.8 mounting plate Th
20、e plate to which the element bundle or containment pocket is attached. 3.9 rated voltage The voltage assigned to the heater by the manufacturer. 3.10 rated power The wattage, at rated voltage, assigned to the heater by the manufacturer. 3.11 thermal insulation A material or system that has the prope
21、rty of resisting the transfer of heat. 3.12 thermostat A temperature-sensing device, the operating temperature of which may be either fixed or adjustable and which, during normal operation, keeps the temperature of the air or gases between certain limits by opening or closing a heater circuit. 3.13
22、temperature limiter A temperature-sensing device, the operating temperature of which may be either fixed or adjustable and which, during normal operation, operates by opening or closing a heater circuit when the temperature reaches a predetermined value. NOTE. A temperature limiter does not make the
23、 reverse operation during the normal duty cycle of the heater. It may or may not require manual resetting. 3.14 thermal cut-out A device which, during abnormal operation, limits the temperature of a heater, or of parts of it, by opening the circuit or by reducing the current, and which is so constru
24、cted that its setting cannot be altered by the user. 3.15 basic insulation Insulation applied to live parts to provide basic protection against electric shock. NOTE. Basic insulation does not necessarily include insulation used exclusively for functional purposes. 3.16 supplementary insulation Indep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS77971998SPECIFICATIONFORINDUSTRIALDUCTHEATERSUSINGMETALSHEATHEDELEMENTS 使用 金属 屏蔽 元件 工业 管道 加热器 规范 PDF

链接地址:http://www.mydoc123.com/p-547049.html