BS 7317-6-1990 Methods for analysis of high purity copper cathode Cu-CATH-1 - Method for determination of phosphorus and silicon by spectrophotometry《高纯度铜阴极Cu-CATH-1分析方法 分光光度法对磷和硅的.pdf
《BS 7317-6-1990 Methods for analysis of high purity copper cathode Cu-CATH-1 - Method for determination of phosphorus and silicon by spectrophotometry《高纯度铜阴极Cu-CATH-1分析方法 分光光度法对磷和硅的.pdf》由会员分享,可在线阅读,更多相关《BS 7317-6-1990 Methods for analysis of high purity copper cathode Cu-CATH-1 - Method for determination of phosphorus and silicon by spectrophotometry《高纯度铜阴极Cu-CATH-1分析方法 分光光度法对磷和硅的.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS7317-6:1990Methods forAnalysis of high purity copper cathodeCu-CATH-1Part 6: Method for determination of phosphorus and silicon by spectrophotometryUDC669.3.015.4:543.422.062:546.18+546.28BS7317-6:1990This BritishStandard, having been prepared under the directionof the Non-ferrous
2、 Metals Standards Policy Committee, was published underthe authority of the BoardofBSI and comesintoeffecton31July1990 BSI01-2000The following BSI references relate to the work on this standard:Committee referenceNFM/34Draft for DevelopmentDD95-6ISBN 0 580 18465 XCommittees responsible for this Brit
3、ish StandardThe preparation of this BritishStandard was entrusted by the Non-ferrous Metals Standards Policy Committee(NFM/-) to Technical CommitteeNFM/34, upon which the following bodies were represented:British Bathroom CouncilBritish Cable Makers ConfederationBritish Gas plcBritish Malleable Tube
4、 Fittings AssociationBritish Non-ferrous Metals FederationBritish Valve and Actuator Manufacturers AssociationCopper Development AssociationLondon Metal ExchangeNon-ferrous Metal StockistsSociety of British Aerospace Companies Ltd.Transmission and Distribution Association (BEAMA Ltd.)Coopted members
5、The following bodies were also represented in the drafting of the standard, through subcommittees and panels:BNF Metals Technology CentreBritish Bronze and Brass Ingot Manufacturers AssociationBureau of Analysed Samples Ltd.Copper Smelters and Refiners AssociationMinistry of DefenceAmendments issued
6、 since publicationAmd. No. Date of issue CommentsBS7317-6:1990 BSI 01-2000 iContentsPageCommittees responsible Inside front coverForeword ii1 Scope 12 Principle 13 Reagents 14 Apparatus 25 Procedure for phosphorus 26 Procedure for silicon 37 Repeatability and reproducibility 48 Test report 4Table 1
7、Phosphorus calibration solutions 2Table 2 Silicon calibration solutions 3Publications referred to Inside back coverBS7317-6:1990ii BSI 01-2000ForewordBS7317 has been prepared under the direction of the Non-ferrous Metals Standards Policy Committee. It describes methods for the determination of impur
8、ity elements in high purity copper cathode designatedCu-CATH-1, each method being published as a separate Part.The methods are based on those previously issued in the Draft for Development series DD95-1 to DD95-7. The information and experience gained from the practical application of DD95 have been
9、 taken into account in the methods in BS7317.This Part of BS7317 supersedes DD95-6:1987, which is withdrawn. It is one of a series of methods in BS7317, the others being as follows: Part 1: Method for determination of cadmium, manganese and silver (screening procedure for chromium, cobalt, iron, nic
10、kel and zinc) by atomic absorption spectrophotometry; Part 2: Method for determination of chromium, cobalt, iron, nickel and zinc by discrete volume nebulization atomic absorption spectrophotometry; Part 3: Method for determination of antimony, arsenic, bismuth, selenium, tellurium and tin by hydrid
11、e generation and atomic absorption spectrophotometry; Part 4: Method for determination of antimony, arsenic, bismuth, lead, selenium, tellurium and tin by electrothermal atomization atomic absorption spectrophotometry; Part 5: Method for determination of sulphur by hydrogen sulphide evolution and sp
12、ectrophotometry; Part 7: Method for determination of lead by lanthanum hydroxide separation and atomic absorption spectrophotometry.The atomic absorption spectrophotometric procedures in Parts1 and2 are complementary. A sample solution concentration found to be satisfactory for nebulizers in standar
13、d atomic absorptiometers was20g/L. At this concentration the precision obtainable, using the method described in Part1, is only sufficient to allow the determination of cadmium, manganese and silver. Results would be obtained for chromium, cobalt, iron, nickel and zinc that would prove useful in det
14、ecting impurities grossly in excess of the requirements for chemical composition specified in BS6017 for Cu-CATH-1 and would give a guide to the levels to be determined by Part2.The discrete volume nebulization procedure in Part2 was developed to enable a higher equivalent sample solution concentrat
15、ion of100g/L to be used without nebulizer blockage. The method involves no chemical separation, which can give rise to contamination problems, and the extra sensitivity obtained enables the impurities to be determined to an adequate accuracy for the requirements for chemical composition specified in
16、 BS6017 for Cu-CATH-1.Parts1 and2 essentially cover the same impurities. Part4 covers the electrothermal atomization atomic absorption spectrophotometric method and is recommended where the facility is available. Parts1,2,3 and7 are included for use where the electrothermal atomization equipment is
17、not available.A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.Summary of pagesThis document
18、 comprises a front cover, an inside front cover, pagesi andii, pages1 to4, an inside back cover and a back cover.This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS7317-6:1990 BSI 01-
19、2000 11 ScopeThis Part of BS7317 describes a method for the determination of the actual amounts of the impurity elements phosphorus and silicon present in high purity copper cathode (designated Cu-CATH-1), by spectrophotometry. It is applicable to concentrations of the elements not exceeding the fol
20、lowing limits: NOTEThe titles of the publications referred to in this Part of BS7317 are listed on the inside back cover.2 PrincipleSeparate samples are taken for phosphorus and silicon and are dissolved respectively in nitric acid and in a nitric/hydrofluoric acid mixture. The phosphorus and silico
21、n present in the samples are converted to the heteropolymolybdate complexes, separated by extraction into organic solvents and determined spectrophotometrically as the reduced complexes.3 Reagents3.1 GeneralDuring the analysis, use only reagents of the highest recognized analytical quality, as free
22、as possible from phosphorus and silicon, and only water that has been double distilled from a quartz apparatus, or water of equivalent purity. Do not use demineralized water.Store all reagents used for the silicon determination in containers made from materials free from silicon, such as polyethylen
23、e. Do not use glass pipettes for solutions that are to be used in the silicon determinations (seenote to4.3).3.2 Hydrogen peroxide,30%m/m3.3 Methanol3.4 Hydrofluoric acid, 1.13g/mL.3.5 4-methylpentan-2-one3.6 Acetone3.7 Nitric acid, 1.42g/mL,50%V/V solution.3.8 Hydrochloric acid, 1.18g/mL,50%V/V sol
24、ution.3.9 Hydrochloric acid, 1.18g/mL,10%V/V solution.3.10 Oxalic acid solution. Dissolve50g of oxalic acid (COOH)2.2H2O in500mL of water.3.11 Orthoboric acid solution, saturated.3.12 Copper(II) nitrate solution. Dissolve152g of copper(II) nitrate Cu(NO3)2.3H2O in600mL of water. Filter if necessary.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS731761990METHODSFORANALYSISOFHIGHPURITYCOPPERCATHODECUCATH1METHODFORDETERMINATIONOFPHOSPHORUSANDSILICONBYSPECTROPHOTOMETRY

链接地址:http://www.mydoc123.com/p-546695.html