BS 7251-8-1990 Orthopaedic joint prostheses - Guide to laboratory evaluation of change of form of bearing surfaces of hip joint prostheses《矫形外科关节假体 第8部分 假髋关节支撑面形状变化实验室评定指南》.pdf
《BS 7251-8-1990 Orthopaedic joint prostheses - Guide to laboratory evaluation of change of form of bearing surfaces of hip joint prostheses《矫形外科关节假体 第8部分 假髋关节支撑面形状变化实验室评定指南》.pdf》由会员分享,可在线阅读,更多相关《BS 7251-8-1990 Orthopaedic joint prostheses - Guide to laboratory evaluation of change of form of bearing surfaces of hip joint prostheses《矫形外科关节假体 第8部分 假髋关节支撑面形状变化实验室评定指南》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS7251-8: 1990 ISO/TR9326: 1989 Orthopaedic joint prostheses Part 8: Guide to laboratory evaluation of change of form of bearing surfaces of hip joint prosthesesBS7251-8:1990 This British Standard, having been prepared under the directionof the Health CareStandards Policy Committee,
2、waspublished underthe authorityof theBoardofBSIand comesintoeffect on 31August1990 BSI 10-1999 The following BSI references relate to the work on this standard: Committee reference HCC/25 Draft for comment87/51091DC ISBN 0 580 18372 6 Committees responsible for this British Standard The preparation
3、of this British Standard was entrusted by the Health Care Standards Policy Committee (HCC/-) to Technical Committee HCC/25, upon which the following bodies were represented: British Institute of Surgical Technologists British Medical Association British Orthopaedic Association British Steel Industry
4、 British Surgical Trades Association Department of Health Department of Trade and Industry (National Engineering Laboratory) Royal College of Surgeons of England Scottish Office Coopted members Amendments issued since publication Amd. No. Date CommentsBS7251-8:1990 BSI 10-1999 i Contents Page Commit
5、tees responsible Inside front cover National foreword ii 1 Scope 1 2 Preparation of test specimens 1 3 General recommendations for measuring wear 1 4 Measurement of wear by weighing 1 5 Measurement of wear by means of dimensional changes 3 6 Measurement of wear by thin layer activation 4 Annex A (in
6、formative) Bibliography 7 Table 1 Summary of methods of estimating dimensional changes 5 Table 2 Thin layer activation of materials for hip prostheses 6 Publication referred to Inside back coverBS7251-8:1990 ii BSI 10-1999 National foreword This Part of BS7251 has been prepared under the direction o
7、f the Health Care Standards Policy Committee and is identical with ISO/TR9326:1989 “Implants for surgery Partial and total hip joint prostheses Guidance for laboratory evaluation of change of form of bearing surfaces”, prepared by Technical Committee150, Implants for surgery, of the International Or
8、ganization for Standardization (ISO). Requirements for orthopaedic implants (then termed “surgical implants”) were first published in1962 as BS3531. In1968 a part revision of BS3531:1962 was issued as BS3531-1, which dealt with surgical implants made of all materials. In1980 the first four Parts of
9、a multi-part version of BS3531 were published. A further nineteen Parts of BS3531 were subsequently published. In view of the increase in the number of Parts, and with a view to facilitating the implementation of published or forthcoming ISO implant standards, the British Standard relating to implan
10、ts has been restructured. Accordingly the number BS3531 is reserved for standards for implants for osteosynthesis, BS7251 covers joint prostheses, BS7252 covers metallic materials for surgical implants, BS7253 covers non-metallic materials for surgical implants and BS7254 covers orthopaedic implants
11、, i.e.aspects common to both osteosynthesis and joint replacement. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunit
12、y from legal obligations. Cross-reference International Standard Corresponding British Standard ISO/TR9325:1989 BS7251 Orthopaedic joint prostheses Part7:1990 Guidance on hip joint simulators (Identical) Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pag
13、es1 to8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS7251-8:1990 BSI 10-1999 1 1 Scope This Technical Report gives guidance on the method
14、s available for the measurement of change of form (wear, creep, plastic deformation, etc.) of the bearing surfaces of hip joint prostheses when tested in hip joint simulators. It highlights the strengths and weaknesses of the methods in an attempt to unify experimental technique and to increase the
15、accuracy, precision and comparability of “wear test” data. NOTEAttention is drawn to ISO/TR9325 regarding hip joint simulators. 2 Preparation of test specimens Test and control specimens should be prepared in accordance with the specific recommendations given in the appropriate clauses of this Techn
16、ical Report and in accordance with the general recommendations in ISO/TR9325. 3 General recommendations for measuring wear Conventional total hip joint prostheses consist of an acetabular bearing surface of polymeric or ceramic material articulating with a femoral component made of metallic or ceram
17、ic material. A change of form of the bearing surfaces will result from wear and/or creep and/or plastic deformation. Wear products may be in solution or particulate. Wear produces a change in the dimensions of the specimen due to the removal of material with consequent loss of mass. Wear should be d
18、istinguished from other types of change of form common in polymeric materials, in which dimensional changes occur without loss of mass, e.g.creep. It is thus advisable or, in some instances depending on the method of assessment, essential to determine the amount of creep separately by a method such
19、as subjecting a stationary component to the same loading cycle, number of loading cycles and environment as the test specimen. It is known that visco-elastic deformation can occur. It is not considered in this Technical Report, but measurements of wear should be completed at the same time after the
20、end of each test in order to minimize the effects of this factor. The collection, inspection, and quantitative analysis of the particulate wear debris produced during a test is recommended, as it is often helpful in studying wear mechanisms. However, it is not recommended as the sole criterion for w
21、ear measurement. It is often essential or desirable to examine the bearing surfaces of the specimens during the course of determining the wear, but such disassembly of the test rig and inspection of specimens should be kept to a minimum because the procedures involved are likely to influence subsequ
22、ent wear mechanisms and rates. Several established methods of estimating wear have been employed, all of which have some advantages whilst none are completely satisfactory or free from disadvantages. The most commonly used method is that of determining the loss in mass of a component, and this (and
23、to a lesser extent other methods) are discussed in subsequent clauses. Brief reference is also made to the evaluation of friction, since this is commonly determined by appropriate sensing and instrumentation during wear testing. 4 Measurement of wear by weighing 4.1 Preparation of specimens In addit
24、ion to the recommendations given in ISO/TR9325, specimens that absorb water should be further prepared in order to minimize the deleterious effects of absorption on the accuracy of weighing the specimen. Preparation of such specimens consists of soaking the specimen in lubricant (see ISO/TR9325) at
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS725181990ORTHOPAEDICJOINTPROSTHESESGUIDETOLABORATORYEVALUATIONOFCHANGEOFFORMOFBEARINGSURFACESOFHIPJOINTPROSTHESES

链接地址:http://www.mydoc123.com/p-546648.html