BS 7019-1989 Specification for fully screened 400 A bolted flameproof cable couplers and adaptors for use on systems up to and including 6 6 kV primarily for use in mines《电压可达或等于6 .pdf
《BS 7019-1989 Specification for fully screened 400 A bolted flameproof cable couplers and adaptors for use on systems up to and including 6 6 kV primarily for use in mines《电压可达或等于6 .pdf》由会员分享,可在线阅读,更多相关《BS 7019-1989 Specification for fully screened 400 A bolted flameproof cable couplers and adaptors for use on systems up to and including 6 6 kV primarily for use in mines《电压可达或等于6 .pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 7019:1989 Specification for Fully screened 400 A bolted flameproof cable couplers and adaptors for use on systems up to and including 6.6 kV, primarily for use in mines UDC 622.812.2:621.315.683-213.34BS7019:1989 This British Standard, having been prepared under the directionof t
2、he Mining and Quarrying Requisites Standards Policy Committee, was published under the authority of the Board ofBSI and comes into effect on 31August1989 BSI 12-1999 The following BSI references relate to the work on this standard: Committee reference MQE/14 Draft for comment 87/75517 DC ISBN 0 580
3、16909 X Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Mining and Quarrying Requisites Standards Policy Committee (MQE/-) to Technical Committee MQE/14 upon which the following bodies were represented: Association of British Mining Equi
4、pment Companies British Cable Makers Confederation British Coal Corporation Council for Electrical Equipment for Flammable Atmospheres (BEAMA Ltd.) Health and Safety Executive Institution of Mining Electrical and Mining Mechanical Engineers Institution of Mining Engineers Rotating Electrical Machine
5、s Association (BEAMA Ltd.) Transmission and Distribution Association (BEAMA Ltd.) Amendments issued since publication Amd. No. Date of issue CommentsBS7019:1989 BSI 12-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Design and construction 2 4 D
6、imensions 4 5 Cable glands and cable sealing boxes 5 6 Type tests 5 7 Routine tests 6 8 Marking 8 Appendix A Information to be supplied with enquiry or order 9 Figure 1 Coupling dimensions 10 Figure 2 Nut for fixed contact element 11 Figure 3 Key for fixed contact element nut 11 Figure 4 Separate co
7、ntact unit 12 Figure 5 Dimension of sealing ring 13 Figure 6 Straight adaptor 14 Figure 7 Angle adaptor 15 Figure 8 Insulated end cover 16 Figure 9 Methods of measuring electrical clearances 17 Figure 10 Coupler glandsets for pliable wire armoured cables 21 Figure 11 Coupler glandsets for single and
8、 double wire armoured cables (SWA illustrated) 22 Table 1 Properties of primary insulating materials 3 Table 2 Properties of the sealing ring 4 Table 3 Minimum creepage and clearance distances 5 Table 4 Details of coupler glandsets 5 Table 5 Bending forces 7 Publications referred to Inside back cove
9、rBS7019:1989 ii BSI 12-1999 Foreword This British Standard has been prepared under the direction of the Mining and Quarrying Requisites Standards Policy Committee. It was devised to rationalize the principal features of fully screened, 400A bolted flameproof cable couplers and associated adaptors fo
10、r use on system voltages up to6.6kV and designed primarily for equipment used in mines. This standard makes provision for special purpose items such as interface units for connection to adaptors and cable couplers specified in BS3454 and BS3905. A British Standard does not purport to include all the
11、 necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Attention is drawn to the Health and Safety at Work etc. Act1974, the Mines and Quarries Act195
12、4, the Regulations made under these Acts, and also any other appropriate statutory requirements or bye-laws. These place responsibility for complying with certain specific safety requirements on the manufacturer and the user. The address of the recognized certification authority in the UK for Group
13、I (coal mining) apparatus for flameproof purposes is as follows: Health and Safety Executive, HSE (M) Certification Support Unit, Harpur Hill, Buxton Derbyshire, SK17 9JN. Copyrights subsist in products made to the illustrations herein. The copyright owner has agreed with BSI to grant licences under
14、 the copyright to all applicants on reasonable and non-discriminating terms. For details apply to the Enquiry Section, BSI, Linford Wood, Milton Keynes, MK 14 6LE, enclosing a stamped addressed envelope for reply. Summary of pages This document comprises a front cover, an inside front cover, pagesia
15、ndii, pages1to22, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS7019:1989 BSI 12-1999 1 1 Scope This British Standard specifies requirement
16、s for400A bolted flameproof cable couplers and adaptors of the fully screened3-phase type with a voltage rating of up to and including6.6kV primarily for use in mines. The couplers are designed to enable two cables to be coupled together or to enable a cable to be coupled to apparatus by use of adap
17、tors. The dimensional and test requirements for cable coupling units also cover conversion units that enable couplers/adaptors complying with this standard to be connected to couplers/adaptors complying with BS3454 and BS3905. In all cases the electrical connections are made by separate connecting e
18、lements. Provision is also made for insulated end covers. The use of other forms of intermediate box, with coupling arrangements as specified in this standard are not precluded, provided that all other relevant requirements of this standard are met. The couplers complying with this standard are prim
19、arily intended for use with3- or4-core, individually screened, wire armoured cables, where the fourth conductor is earthed. Couplers and adaptors complying with this standard are not intended to be coupled or uncoupled while the circuit is energized. The dimensions necessary to provide for the conne
20、ction of couplers of different manufacture and some electrical and mechanical requirements are specified. This standard does not, however, purport to specify a fully detailed design. Information to be supplied by the purchaser with the enquiry or order is given in Appendix A. NOTEThe titles of the p
21、ublications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this British Standard the following definitions apply. 2.1 cable coupling unit a detachable cable sealing box utilizing suitable connecting elements to facilitate ready connection to, or d
22、isconnection from, a similar unit or other apparatus 2.2 bolted flameproof cable coupler two cable coupling units complete with suitable contact elements and a sealing ring, that, when bolted together to form a straight-through connecting box, complies with the relevant requirements of BS4683-2, and
23、 BS5501-5 2.3 cable gland a device designed to secure the end of the cable to the cable sealing box, by means appropriate to the type of cable, including provision for making electrical connection to the armouring, screens and lead sheath of the cable, where applicable 2.4 cable sealing box a device
24、 designed to receive and protect the end of the cable, with provision for sealing the conductors and the insulating material of the cable with filling medium and having a cable gland for attaching the cable to the box, together with any terminals provided for connection to the conductors of the cabl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS70191989SPECIFICATIONFORFULLYSCREENED400ABOLTEDFLAMEPROOFCABLECOUPLERSANDADAPTORSFORUSEONSYSTEMSUPTOANDINCLUDING66KVPRIMARILYFORUSEINMINES

链接地址:http://www.mydoc123.com/p-546475.html