BS 6706-1986 Specification for disposable glass serological pipettes《一次性使用的血清玻璃吸移管规范》.pdf
《BS 6706-1986 Specification for disposable glass serological pipettes《一次性使用的血清玻璃吸移管规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6706-1986 Specification for disposable glass serological pipettes《一次性使用的血清玻璃吸移管规范》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS6706:1986 Specification for Disposable glass serological pipettes UDC 542.3:531.732:666.172.7BS6706:1986 This BritishStandard, having been prepared under the directionof the Laboratory Apparatus Standards Committee,was published underthe authority of the BoardofBSI and comes intoe
2、ffecton 31October1986 BSI 12-1999 The following BSI references relate to the work on this standard: Committee reference LBC/27 Draft for comment82/52908 DC ISBN 0 580 15161 1 Committees responsible for this BritishStandard The preparation of this BritishStandard was entrusted by the Laboratory Appar
3、atus Standards Committee (LBC/-) to Technical Committee LBC/27 upon which the following bodies were represented: Association of Clinical Biochemists British Laboratory Ware Association British Lampblown Scientific Glassware Manufacturers Association Ltd Department of Health and Social Security Depar
4、tment of Trade and Industry (Laboratory of the Government Chemist) Department of Trade and Industry (National Weights and Measures Laboratory) Glass Manufacturers Federation Institute of Medical Laboratory Sciences Medical Sterile Products Association Ministry of Defence Society of Chemical Industry
5、 South Western Regional Health Authority Amendments issued since publication Amd. No. Date of issue CommentsBS6706:1986 BSI 12-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Classification 1 4 Basis of adjustment 1 5 Construction 1 6 Delivery t
6、ime 2 7 Volumetric performance 2 8 Graduation and figuring 2 9 Inscriptions 3 10 Labelling 3 11 Colour coding 3 Appendix A Determination of delivered capacity 4 Appendix B Determination of accuracy and repeatability 4 Table 1 Capacity, subdivision, dimensions and delivery time 2 Publications referre
7、d to Inside back coverBS6706:1986 ii BSI 12-1999 Foreword This BritishStandard has been prepared under the direction of the Laboratory Apparatus Standards Committee. This BritishStandard is related to ISO7713:1985 published by the International Organization for Standardization (ISO), differing from
8、its technical requirements in the following respects: a) the external diameter of the0.5mL and1.0mL pipettes is4.0mm to4.75mm instead of4.25mm to4.75mm; b) the external diameter of the5mL pipette is6.5mm to8.25mm instead of7.0mm to8.25mm; c) the minimum wall thickness of the0.5mL,1mL,2mL and5mL pipe
9、ttes is0.5mm instead of0.6mm; d) the blow-out type may, in addition or as an alternative to being inscribed with a white band, be inscribed with the wording “Blow-out”. Purchasers ordering to this standard are advised to specify in their purchasing contract that the supplier operates a quality syste
10、m in compliance with BS5750-3 to ensure that products claimed to comply with BS6706 consistently achieve the required level of quality. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application.
11、 Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may h
12、ave had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS6706:1986 BSI 12-1999 1 1 Scope This BritishStandard specifies the dimensions and construction of a range of disposable serological pipettes suitable for general laboratory purposes. A method f
13、or determining volumetric performance of the pipettes is included. Two types (flow-out and blow-out) are specified. NOTE 1The requirements specified in this standard are in accordance with the principles described in ISO8417 and the pipettes specified in this standard are related to those specified
14、in ISO7713 (seeforeword). ISO8417 is in preparation but it is expected to be published as a dual-numbered BritishStandard. NOTE 2The titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this BritishStandard the following defin
15、itions apply. 2.1 disposable serological pipette a serological pipette intended to be used once only and then discarded NOTESuch pipettes will only be expected to provide their specified performance during the original operation. 2.2 standard reference temperature the temperature at which the serolo
16、gical pipette is intended to deliver its nominal volume (nominal capacity) 2.3 delivered capacity of flow-out pipettes the volume, in millilitres, of water corresponding to any graduation line, delivered by the pipette, at the standard reference temperature, when emptied from the zero line to that g
17、raduation line; the outflow is unrestricted until making the final setting of the meniscus on the graduation line and no period is allowed for drainage of liquid adhering to the wall before making the final setting 2.4 delivered capacity of blow-out pipettes the volume, in millilitres, of water corr
18、esponding to any graduation line, delivered by the pipette, at the standard reference temperature, when emptied from the graduation line to the jet; the outflow is unrestricted until the meniscus has come to rest in the jet but delivery is completed by expelling the last drop by blowing NOTEIt shoul
19、d be borne in mind that the delivered volume is the complement of that indicated, e.g.if the indication on a10mL pipette is4mL, the delivered volume is6mL. 2.5 delivery time the time taken for the descent of the water meniscus, at the standard reference temperature, from the zero graduation line to
20、the point at which it appears to come to rest in the jet 2.6 accuracy the closeness of agreement between the nominal volume and the mean volume, obtained by applying the test procedure specified in clause7. It is quantified by the inaccuracy of the mean 2.7 repeatability the closeness of agreement b
21、etween the individual volumes obtained by applying the test procedure specified in clause7. It is quantified by imprecision NOTEThe definitions for accuracy and repeatability apply only in cases where the distributions are gaussian. 3 Classification The disposable serological pipettes shall be of th
22、e types described in a) or b) as follows: a) flow-out type, in which the delivered capacity is obtained without expelling the final drop by blowing; b) blow-out type, in which the delivered capacity is obtained by expelling the final drop by blowing. 4 Basis of adjustment 4.1 Unit of volume The unit
23、 of volume shall be either the millilitre or the cubic centimetre. NOTEThe millilitre is commonly used as a name for the cubic centimetre, in accordance with the International System of Units (SI). 4.2 Standard reference temperature The standard reference temperature shall be20 C, except when the se
24、rological pipette is required for use in a country that has adopted a standard reference temperature of27 C, in which case27 C shall be the standard reference temperature. NOTE27 C is the alternative standard reference temperature recommended in BS5898 for tropical use. 5 Construction 5.1 Material D
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS67061986SPECIFICATIONFORDISPOSABLEGLASSSEROLOGICALPIPETTES 一次性 使用 血清 玻璃 吸移管 规范 PDF

链接地址:http://www.mydoc123.com/p-546189.html