BS 67-1987 Specification for ceiling roses《天花板接线盒规范》.pdf
《BS 67-1987 Specification for ceiling roses《天花板接线盒规范》.pdf》由会员分享,可在线阅读,更多相关《BS 67-1987 Specification for ceiling roses《天花板接线盒规范》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 67:1987 Specification for Ceiling roses UDC 621.315.673:614.8BS67:1987 This British Standard, having been prepared under the directionof the Power ElectricalEngineering StandardsCommittee, was published under the authority ofthe Board of BSI and comesintoeffect on 27 February 198
2、7 BSI 09-1999 First published August 1914 First revision May 1929 Second revision October 1938 Third revision June 1969 Fourth revision February 1987 The following BSI references relate to the work on this standard: Committee reference PEL/4 Draftfor comment 84/27023 DC ISBN 0 580 15692 3 Committees
3、 responsible for this British Standard The preparation of this British Standard was entrusted by the Power Electrical Engineering Standards Committee (PEL/-) to Technical Committee PEL/4, upon which the following bodies were represented: ASTA Certification Services Association of Consulting Engineer
4、s Association of Control Manufacturers TACMA (BEAMA Ltd.) Association of Manufacturers of Domestic Electrical Appliances British Electrical Systems Association (BEAMA Ltd.) British Electrotechnical Approvals Board British Plastics Federation Consumer Standards Advisory Committee of BSI Department of
5、 Health and Social Security Department of Trade and Industry (Consumer Safety Unit, C A Division) ERA Technology Ltd. Electrical Association for Women Electrical Contractors Association Electrical Installation Equipment Manufacturers Association (BEAMA Ltd.) Electrical Power Engineers Association El
6、ectricity Supply Industry in England and Wales Institution of Electrical Engineers Lighting Industry Federation Ltd. National Economic Development Office National Inspection Council for Electrical Installation Contracting The following body was also represented in the drafting of the standard, throu
7、gh a subcommittee: Decorative Lighting Association Amendments issued since publication Amd. No. Date of issue CommentsBS67:1987 BSI 09-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Conditions of use 1 3 Definitions 1 4 General requirements 2 5 General conditi
8、ons for type testing 2 6 Ratings 2 7 Classification 2 8 Marking and information 3 9 Dimensions 3 10 Accessibility of live parts 3 11 Provision for earthing 4 12 Terminals 4 13 Construction 7 14 Resistance to moisture and humidity, insulation resistance and electric strength 8 15 Temperature rise 9 1
9、6 Mechanical strength 10 17 Resistance to heat 10 18 Resistance to abnormal heat, fire and tracking 11 19 Screws, current-carrying parts and connections 13 20 Creepage distances and clearances 13 21 Resistance to excessive residual stresses and to rusting 13 Appendix A Measurement of creepage distan
10、ces and clearances 19 Figure 1 Pendulum impact test apparatus 14 Figure 2 Constructional details of striking element 15 Figure 3 Construction details of mounting support for test specimens 15 Figure 4 Ball pressure test apparatus 16 Figure 5 Glow wire with thermocouple 16 Figure 6 Glow-wire test app
11、aratus 17 Figure 7 Arrangement and dimensions of the electrodes for the tracking test 18 Table 1 Terminal screw torque values 5 Table 2 Test currents for test on screwless terminals 7 Table 3 Application of glow-wire test 12 Table 4 Creepage distances and clearances 13 Publications referred to Insid
12、e back coverBS67:1987 ii BSI 09-1999 Foreword This revision of this British Standard has been prepared under the direction of the Power Electrical Engineering Standards Committee and supersedes BS67:1969. This revised standard comes into force immediately, but to allow manufacturers time to design a
13、nd introduce any necessary changes, BS 67:1969 will not be withdrawn until 31 December 1987. NOTEUpon publication of this revision, BSI Sales Department will respond to purchase orders for BS 67 by supplying copies of the 1987 edition. Copies of the 1969 edition may be obtained by quoting the number
14、 “BS 67/BS69” The main purpose of the revision has been to update the standard so as to bring the requirements and tests into line with other recently published BritishStandards for accessories which have taken account of relevant InternationalStandards. A British Standard does not purport to includ
15、e all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi
16、andii, pages1 to20, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS67:1987 BSI 09-1999 1 1 Scope This British Standard specifies requirement
17、s for ceiling roses having maximum ratings of 6 A and250 V intended for use in final circuits rated at16 A maximum for ceiling roses with screw-type supply terminals or 10 A maximum for ceiling roses with screwless supply terminals. The requirements specified in this standard have particular referen
18、ce to safety in use. The ceiling roses are intended for use with cables complying with BS 6004 or BS 6007 having copper conductors and for use with flexible cords complying with BS 6500. Ceiling roses incorporating means other than rewirable terminals, to facilitate the connection and disconnection
19、of lampholders or luminaires, are not covered by this standard. NOTE 1Accessories complying with this standard may be regarded as lighting outlets. NOTE 2The titles of the publications referred to in this standard are listed on the inside back cover. 2 Conditions of use Ceiling roses shall be suitab
20、le for use under the following conditions: a) an ambient temperature having a peak value not exceeding 40 C, with an average value not exceeding 35 C in a period of 24 h, but not subject to exposure to direct radiation from the sun or any other source of heat likely to raise the temperature above th
21、e specified ambient temperature; b) an ambient temperature having a value not less than 5 C; c) an altitude not exceeding 2000 m above sea level; d) an atmosphere not subject to excessive pollution by smoke, chemical fumes, salt laden spray, prolonged periods of high humidity or other abnormal condi
22、tions. 3 Definitions For the purposes of this British Standard the following definitions apply. 3.1 ceiling rose an accessory for connection to the fixed wiring of an installation to pass current to a lampholder or a luminaire by means of the conductors of a flexible cord 3.2 surface-type ceiling ro
23、se a ceiling rose provided with a seating surface such that when mounted as intended it projects wholly outside the surface on which it is mounted 3.3 semi-recessed or flush-type ceiling rose a ceiling rose intended for mounting with its base partially or completely sunk into a box complying with BS
24、 31, BS 4568-2, BS 4607-5 or BS 4662 3.4 terminal housing that part of the ceiling rose which locates and separates the terminals NOTEThe terminal housing may, or may not, be integral with the base. 3.5 terminal a means by which the user can make an electrical connection between the appropriate cabl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS671987SPECIFICATIONFORCEILINGROSES 天花板 接线 规范 PDF

链接地址:http://www.mydoc123.com/p-546184.html