BS 6674-1985 Specification for disposable micropipettes《一次性使用的微量吸移管规范》.pdf
《BS 6674-1985 Specification for disposable micropipettes《一次性使用的微量吸移管规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6674-1985 Specification for disposable micropipettes《一次性使用的微量吸移管规范》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6674:1985 ISO 7550:1985 Specification for Disposable micropipettes ISO title: Laboratory glassware Disposable micropipettes UDC 542.3:531.732 + 666.172.7181.48BS6674:1985 This British Standard, having been prepared under the directionof the Laboratory Apparatus Standards Committe
2、e,was published underthe authority of the BoardofBSI and comes into effect on 31 December 1985 BSI 10-1999 The following BSI references relate to the work on this standard: Committee reference LBC/27 Draft for comment 82/52909 DC ISBN 0 580 14881 5 Committees responsible for this British Standard Th
3、e preparation of this British Standard was entrusted by the Laboratory Apparatus Standards Committee (LBC/-) to Technical Committee LBC/27 upon which the following bodies were represented: Association of Clinical Biochemists British Laboratory Ware Association British Lampblown Scientific Glassware
4、Manufacturers Association Ltd. Department of Health and Social Security Department of Trade and Industry (Laboratory of the Government Chemist) Department of Trade and Industry (National Weights and Measures Laboratory) Glass Manufacturers Federation Institute of Medical Laboratory Sciences Medical
5、Sterile Products Association Ministry of Defence Society of Chemical Industry Amendments issued since publication Amd. No. Date of issue CommentsBS6674:1985 BSI 10-1999 i Contents Page Committees responsible Inside front cover National foreword ii 1 Scope and field of application 1 2 References 1 3
6、Definitions 1 4 Basis of adjustment 1 5 Dimensions, types, series of capacities 1 6 Construction 1 7 Volumetric performance 2 8 Definition of capacity 2 9 Determination of accuracy and repeatability 2 10 Inscriptions and markings 3 Figure 1 Type I pipettes 4 Figure 2 Type II pipettes 5 Table 1 Requi
7、rements for type I pipettes 4 Table 2 Requirements for type II pipettes 5 Publications referred to Inside back coverBS6674:1985 ii BSI 10-1999 National foreword This British Standard has been prepared under the direction of the Laboratory Apparatus Standards Committee and is identical withISO7550:19
8、85 “Laboratory glassware Disposable micropipettes”, published by the International Organization for Standardization (ISO). Terminology and conventions. The text of the International Standard has been approved as suitable for publication as a British Standard without deviation. Some terminology and c
9、ertain conventions are not identical with those used in British Standards; attention is drawn especially to the following. The comma has been used as a decimal marker. In British Standards it is current practice to use a full point on the baseline as the decimal marker. Except in10.1 h), wherever th
10、e words “International Standard” appear, referring to this standard, they should be read as “British Standard”. In British Standards it is current practice to use the symbol “L” for litre (and its submultiples) rather than “l”. The Technical Committee has reviewed the provisions ofISO1769, to which
11、reference is made in the text, and has decided that they are acceptable for use in conjunction with this standard. A related British Standard toISO1769 isBS3996:1978 “Specification for colour coding for one-mark and graduated pipettes (including requirements for the service performance of the colour
12、 coding enamels)”. The reference toISO8417 1)in the text is for information only and does not affect the validity of this standard. Additional information. (1) Purchasers ordering to this standard are advised to specify in their purchasing contract that the supplier operate a quality system in compl
13、iance withBS5750-1 to ensure to their satisfaction that products claimed to comply withBS6674 consistently achieve the required level of quality. (2) Attention is drawn to the option of marking with the BS number 2)given in10.1 h). NOTETypographical error. In 9.2 b) V ishould read V i . Cross-refere
14、nces International Standards Corresponding British Standards ISO 719:1981 BS 3473 Chemical resistance of glass used in the production of laboratory glassware Part 2:1982 Method for determination of hydrolytic resistance of glass grains at98 C (Identical) ISO 3534:1977 BS 5532:1978 Statistics Vocabul
15、ary and symbols (Identical) 1) In preparation. 2) MarkingBS6674 on or in relation to a product is a claim by the manufacturer that the product has been manufactured to the requirements of the standard. The accuracy of such a claim is therefore solely the manufacturers responsibility. Enquiries as to
16、 the availability of third party certification to support such claims should be addressed to the Director, Quality Assurance Division, BSI, PO Box 375, Milton Keynes MK14 6LO for certification marks administered by BSI or to the appropriate authority for other certification marks.BS6674:1985 BSI 10-
17、1999 iii A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document c
18、omprises a front cover, an inside front cover, pages i to iv, pages1to 6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.iv blankBS6674:1985 B
19、SI 10-1999 1 1 Scope and field of application This International Standard specifies requirements for disposable glass micropipettes adjusted to contain, suitable for general laboratory purposes. The details specified are in conformity withISO8417. 2 References ISO 719, Glass Hydrolytic resistance of
20、 glass grains at98 C Method of test and classification. ISO 1769, Laboratory glassware Pipettes Colour coding. ISO 3534, Statistics Vocabulary and symbols. ISO 8417, Laboratory volumetric instruments Disposable volumetric articles Principles of design and construction 3) . 3 Definitions For the purp
21、ose of this International Standard, the following definitions apply. 3.1 disposable micropipette a micropipette intended to be used once only and then discarded NOTESuch pipettes will only be expected to provide their specified performance during the original operation. 3.2 accuracy (of a micropipet
22、te) the closeness of agreement between the nominal volume and the mean volume, obtained by applying the test procedure specified in clause9. It is quantified by the inaccuracy of the mean 3.3 repeatability (of a micropipette) the closeness of agreement between the individual volumes obtained by appl
23、ying the test procedure specified in clause9. It is quantified by the imprecision NOTEThe definitions for “accuracy” and “reliability” apply only in the cases where the distributions are Gaussian. 4 Basis of adjustment 4.1 Unit of volume The unit of volume is the cubic millimetre (mm 3 ), for which
24、the name microlitre (4l) may be used. NOTEThe term microlitre (4l) is commonly used as a special name for the cubic millimetre (mm 3 ), in accordance with the International System of Units (SI). 4.2 Reference temperature The reference temperature, i.e. the temperature at which the pipette is intende
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS66741985SPECIFICATIONFORDISPOSABLEMICROPIPETTES 一次性 使用 微量 吸移管 规范 PDF

链接地址:http://www.mydoc123.com/p-546178.html