1、BRITISH STANDARD BS 667:2005 Illuminance meters Requirements and test methods ICS 17.180.20; 29.140.40 BS 667:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 January 2005 First published December 1945 Second edition February 1968 Thir
2、d edition October 1996 Fourth edition January 2005 The following BSI references relate to the work on this British Standard: Committee reference: CPL/34/5 Special announcement in Update Standards September 2004 ISBN 0 580 44391 4 Committees responsible for this British Standard The preparation of th
3、is British Standard was entrusted by Technical Committee CPL/34, Lamps and related equipment, to Subcommittee CPL/34/5, Photometry and light classifications, upon which the following bodies were represented: Chartered Institution of Building Services Engineers GAMBICA (BEAMA Ltd.) Institution of Civ
4、il Engineers Institution of Electrical Engineers (IEE) Institution of Lighting Engineers Lighting Industry Federation Ltd. National Physical Laboratory Co-opted members Amendments issued since publication Amd. No Date CommentsBS 667:2005 BSI 28 January 2005 i Contents Page Committees responsible Ins
5、ide front cover Foreword ii Introduction 1 1S c o p e 1 2 Normative references 1 3T e r m s a n d d e f i n i t i o n s 1 4 Classification 2 5 Digital ranges and readouts 3 6 Analogue scales 3 7 Calibration and testing temperature 3 8 Power supply 3 9 Performance requirements for laboratory and fiel
6、d illuminance meters 3 10 Marking 5 Annex A (informative) Guidance on choice of meter range 6 Annex B (normative) Calibration 6 Annex C (normative) Test methods 8 Bibliography 13 Table 1 Test and calibration methods 4 Table 2 Error tolerances for illuminance meters 4 Table C.1 Example of calculation
7、 of correction factor for a high pressure sodium lamp 12BS 667:2005 ii BSI 28 January 2005 Foreword This British Standard has been prepared by Subcommittee CPL/34/5. Together with BS EN 13032-1:2004, it supersedes BS 667:1996, which is withdrawn. This British Standard specifies the requirements for
8、two types of illuminance meter: Type L: laboratory instruments, and Type F: field instruments. The error tolerances have been considered in a similar manner to that used in CIE Publication 69 1, and the definitions are based on CIE Publication 17.4 2. Error tolerances for Type L meters have been ali
9、gned with those given in BS EN 13032-1:2004, Table 3. BS EN 13032-1 specifies laboratory illuminance meters for testing luminaires only. It does not cover illuminance meters for other laboratory purposes or for field use. This new edition of BS 667 incorporates changes necessitated by the publicatio
10、n of BS EN 13032-1:2004. It does not reflect a full review or revision of the standard which will be undertaken in due course. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standar
11、d does not of itself confer immunity from legal obligations. Summary of pages This document consists of a front cover, an inside front cover, pages i and ii, pages 1 to 13 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.BS 667:2004 BS
12、I 28 January 2005 1 Introduction As lighting levels reduce, the response characteristics of the human eye change from photopic during the day through an intermediate mesopic region at dusk to a scotopic response at night time. At present, eye response functions have not been defined in the mesopic r
13、egion; research work is still in progress on this subject. Although photopic measurements are generally only applicable at lighting levels above about 10 lux, in practice lighting levels for installations are specified at values significantly below this. It is therefore necessary to make illuminance
14、 measurements with known accuracy at these lower levels to check performance against such specifications, whilst accepting that these measurements do not accurately represent the visual response. Photometric measurements, even under laboratory conditions, are more difficult to determine precisely th
15、an many other kinds of physical measurement, and in the case of illuminance meters, liability to error is increased by the fact that many of the essential components of such instruments are susceptible to variation with time and use. These errors can be minimized by care in the design of the instrum
16、ent as a whole, and also by the user in not exposing it to deleterious conditions of temperature, illumination or atmosphere. It is recommended that illuminance meters should be returned to the manufacturer, or a competent photometric testing authority at intervals as recommended by the manufacturer
17、 for checking and, if necessary, recalibration. 1 Scope This British Standard specifies performance requirements for illuminance meters for the measurement of photopic illuminance for applications other than the measurement of luminaires. It specifies the performance requirements for two types of il
18、luminance meter, Type L (laboratory instruments) and Type F (field instruments). This British Standard is applicable to meters for the measurement of planar illuminance. This standard is intended for use by meter manufacturers and users. NOTE 1 The requirements specified for a Type L meter in this s
19、tandard are identical to the requirements specified for an illuminance meter in BS EN 13032-1. However, BS EN 13032-1 specifies additional requirements which are not specified in this standard. NOTE 2 If other types of illuminance e.g. semi-cylindrical, are used, reference should be made to CIE Publ
20、ication 69:1987 1. NOTE 3 Annex A gives recommendations for the choice of meter range. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of
21、 the referenced document (including any amendments) applies. BS ISO 10526:1999, CIE standard illuminants for colorimetry. CIE Publication 18.2:1983, The basis of physical photometry. Second edition. 3 Terms and definitions For the purposes of this British Standard the following terms and definitions
22、 apply. 3.1 illuminance the luminous flux per unit area falling on a surface, usually measured in lux (lumens per square metre) 3.2 illuminance meter instrument for measuring illuminance 3.3 photoelectric cell detector of optical radiation in which the absorption of photons results in the generation
23、 of an electric current or voltage, or causes a change in electrical resistance NOTE The term “photoelectric detector” is also in use.BS 667:2004 2 BSI 28 January 2005 3.4 selective or coloured filter medium which changes the spectral distribution of radiation by transmission 3.5 colour temperature
24、temperature of the full radiator which emits radiation of the same (or nearly the same) chromaticity as the radiation considered 3.6 photometer head light sensitive detector the spectral response of which is weighted (usually by means of coloured filters) to approximate the CIE spectral luminous eff
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS6672005ILLUMINANCEMETERSREQUIREMENTSANDTESTMETHODS 照度计 试验 方法 要求 PDF

链接地址:http://www.mydoc123.com/p-546177.html