BS 6622-2007 Electric cables - Armoured cables with thermosetting insulation for rated voltages from 3 8 6 6 kV to 19 33 kV - Requirements and test methods《电缆 额定电压在3 8 6 6 kV~19 33.pdf
《BS 6622-2007 Electric cables - Armoured cables with thermosetting insulation for rated voltages from 3 8 6 6 kV to 19 33 kV - Requirements and test methods《电缆 额定电压在3 8 6 6 kV~19 33.pdf》由会员分享,可在线阅读,更多相关《BS 6622-2007 Electric cables - Armoured cables with thermosetting insulation for rated voltages from 3 8 6 6 kV to 19 33 kV - Requirements and test methods《电缆 额定电压在3 8 6 6 kV~19 33.pdf(60页珍藏版)》请在麦多课文档分享上搜索。
1、BS 6622:2007Electric cables Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV Requirements and test methodsICS 29.060.20NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDIncorporatingCorrigenda Nos. 1 and 2Publishing and
2、copyright informationThe BSI copyright notice displayed in this document indicates when the document was last issued. BSI 2008ISBN 978 0 580 64039 1The following BSI references relate to the work on this standard:Committee reference GEL/20/16Draft for comment 06/30143016 DCPublication historyFirst p
3、ublished September 1985Second edition June 1991Third edition January 1999Fourth edition March 2007Amendments issued since publicationAmd. no. Date Text affected17200Corrigendum No. 1June 2007 Paragraph added to 11.2.1.First paragraph of 12.2.1 amended.Reference corrected in 18.12.Wording corrected i
4、n 17.3.Reference corrected in E.2.6.C2 August 2008 See 20.6 and 20.7BS 6622:2007 BSI 2008 iBS 6622:2007ContentsForeword iii1 Scope 12 Normative references 13 Terms and definitions 24 Voltage designation 45 Conductors 46 Conductor screen 47 Insulation 48 Insulation screen 59 Assembly of three-core ca
5、bles, including inner coverings and fillers 510 Metallic layer 711 Metallic armour 812 Oversheath 913 Marking 1014 End sealing 1115 Schedule of tests 1216 Test conditions 1417 Routine tests 1418 Sample tests 1619 Type tests Materials 2120 Type tests Electrical 24AnnexesAnnex A (informative) Recommen
6、dations for the selection of cables 28Annex B (normative) Information to be supplied and items to be agreed 32Annex C (informative) Recommendations for the installation of cables 33Annex D (informative) Guide to use of cables 36Annex E (normative) Fictitious calculation method for determination of d
7、imensions of protective coverings 39Annex F (normative) Rounding of numbers 42Annex G (informative) Guidance on the scope of type tests 43Annex H (normative) Thickness measurements 45Annex I (normative) Test method for cold strippability of the extruded semi-conducting layer of an insulation screen
8、46Annex J (normative) Method for measurement of resistivity of extruded semi-conducting conductor screen and insulation screen 47Annex K (normative) Method for measurement of resistivity of lapped inner covering 51Annex L (normative) Wet compatibility test for galvanized steel wires and semi-conduct
9、ing tape layers 51Bibliography 53List of figuresFigure J.1 Test piece and arrangement of electrodes for measurement of resistivity of the conductor screen 49Figure J.2 Test piece and arrangement of electrodes for measurement of resistivity of the insulation screen 50Figure L.1 Test cell for wet comp
10、atibility test of galvanized steel wires and semi-conducting tape layers 52BS 6622:2007ii BSI 2008List of tablesTable 1 Nominal thickness of insulation 5Table 2 Thickness of extruded inner covering 6Table 3 Nominal diameter of round armour wires 8Table 4 Schedule of tests 12Table 5 Tolerances on tem
11、perature values 14Table 6 D.C. resistance of copper wire screen 15Table 7 Voltage for partial discharge test 15Table 8 Voltage for test on complete cable 16Table 9 Number of samples for the four-hour voltage test and the hot set test on the insulation 17Table 10 Voltages for four-hour voltage test 2
12、0Table 11 Mass of zinc coating 22Table 12 Conditions for oversheath shrinkage test 23Table 13 Compatibility requirements 24Table 14 Tan in relation to voltage 25Table 15 Tan in relation to temperature 26Table 16 Voltage for impulse voltage test 27Table A.1 Selection of cables for three-phase a.c. sy
13、stems 30Table C.1 Bending radius during installation 33Table C.2 Bending radius during installation for cables adjacent to joints or terminations 33Table E.1 Fictitious diameter of conductor 40Table E.2 Increase of diameter for concentric conductors and metallic screens 41Summary of pagesThis docume
14、nt comprises a front cover, an inside front cover, pages i to iv, pages 1 to 53 and a back cover. BSI 2008 iiiBS 6622:2007ForewordPublishing informationThis British Standard was published by BSI and came into effect on 30 March 2007. It was prepared by Subcommittee GEL/20/16, Medium/high voltage cab
15、les under the authority of Technical Committee GEL/20, Electric cables. A list of organizations represented on this committee can be obtained on request to its secretary. SupersessionThis British Standard supersedes BS 6622:1999, which is withdrawn.Information about this documentThis revision of BS
16、6622 has been prepared to bring the requirements up to date in accordance with current practice in the industry and to align with the methods used for calculating cable component dimensions given in IEC 60502-2.This revision of BS 6622 specifies armoured cables. Unarmoured cables, which were specifi
17、ed in the previous edition or BS 6622, are no longer included. Unarmoured cables with a copper wire screen, which were specified in BS 6622:1999, are generally for use by the utilities and are now specified in BS 7870-4.This standard specifies requirements for cables in the rated voltage range from
18、3.8/6.6 kV up to 19/33 kV which are insulated with cross-linked polyethylene (XLPE) or ethylene propylene rubber compound (EPR). Cables with improved performance under fire conditions are specified in BS 7835.Hazard warningsWARNING. This British Standard calls for the use of substances and/or proced
19、ures that can be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not absolve the user from legal obligations relating to health and safety at any stage.Use of this documentIt has been assumed in the preparation of this British Standard that
20、 the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the prin
21、cipal auxiliary verb is “shall”.Commentary, explanation and general informative material is presented in smaller italic type and does not constitute a normative element.Contractual and legal considerationsThis publication does not purport to include all necessary provisions of a contract. Users are
22、responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.iv BSI 2008 This page deliberately left blankBS 6622:2007 BSI 2008 1BS 6622:20071 ScopeThis British Standard specifies requirements and test methods for the construction, dimensio
23、ns and mechanical and electrical properties of armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 (7.2) kV up to 19/33 (36) kV inclusive, designed for a maximum continuous conductor operating temperature of 90 C and for a maximum short circuit conductor temperature of 250
24、C, for use in fixed installations such as networks or industrial installations.This British Standard specifies single-core and three-core cables for voltages in the range 3.8/6.6 (7.2) kV up to 19/33 (36) kV, with: a stranded copper, stranded aluminium or solid aluminium conductor or conductors; cro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS66222007ELECTRICCABLESARMOUREDCABLESWITHTHERMOSETTINGINSULATIONFORRATEDVOLTAGESFROM3866KVTO1933KVREQUIREMENTSANDTESTMETHODS

链接地址:http://www.mydoc123.com/p-546157.html