BS 6556-1-1985 Low speed digital signals for use in coal mines - Specification for optical coupling《煤矿用低速数字信号 第1部分 光耦合规范》.pdf
《BS 6556-1-1985 Low speed digital signals for use in coal mines - Specification for optical coupling《煤矿用低速数字信号 第1部分 光耦合规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6556-1-1985 Low speed digital signals for use in coal mines - Specification for optical coupling《煤矿用低速数字信号 第1部分 光耦合规范》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6556-1: 1985 Incorporating Amendment No. 1 Low speed digital signals for use in coal mines Part 1: Specification for optical coupling UDC 622.489:621.398.037.37:681.327.8BS6556-1:1985 This British Standard, having been prepared under the directionof the Mining and Quarrying Requi
2、sites StandardsCommittee, was published under the authority ofthe Board of BSI and comes into effect on 31January1985 BSI 10-1999 The following BSI references relate to the work on this standard: Committee reference MQE/25 Draft for comment 82/76934 DC ISBN 0 580 14179 9 Committees responsible for t
3、his British Standard The preparation of this British Standard was entrusted by the Mining and Quarrying Requisites Standards Committee (MQE/-) to Technical Committee MQE/25upon which the following bodies were represented: Association of British Mining Equipment Companies Council for Electrical Equip
4、ment for Flammable Atmospheres (BEAMA) Health and Safety Executive National Coal Board National Union of Mineworkers Amendments issued since publication Amd. No. Date of issue Comments 6204 May 1990 Indicated by a sideline in the marginBS6556-1:1985 BSI 10-1999 i Contents Page Committees responsible
5、 Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 General conventions 1 4 Data link configurations 1 5 Channel allocation 1 6 Data rate 1 7 Electrical network parameters 1 8 System performance 2 9 Cable connections 2 10 Environment 2 11 Maximum output parameters 2 12 Marking 2 13 Documenta
6、tion 3 Appendix A Cable parameters used for system performance test 6 Figure 1 Simplex operation 3 Figure 2 Duplex point-to-point operation 3 Figure 3 Multi-drop operation 4 Figure 4 Originate channel 5 Figure 5 Answer channel 5 Figure 6 Core configuration of cable 6 Publications referred to Inside
7、back coverBS6556-1:1985 ii BSI 10-1999 Foreword This Part of BS6556has been prepared under the direction of the Mining and Quarrying Requisites Standards Committee. Control and monitoring activities below ground in coal mines require the transmission of data between items of electrical equipment sup
8、plied by different manufacturers. Data can be transmitted in analogue or alternatively digital form. For analogue, BS 5754:1980 “Specification for electrical analogue and state signals for use in coal mines” was produced with the purpose of promoting compatibility between transducers, recorders, ind
9、icators and data transmission systems of different manufacture and having inputs or outputs, as appropriate, in the form of d.c. voltage analogue signals or signals derived from relay contacts or a mechanical switch. This standard deals with the digital form. A major disadvantage with control and mo
10、nitoring systems employing the direct transmission of analogue signals is that since a galvanic connection is necessary between the transmitting and receiving circuits, faults, at different points of the system, particularly to earth, can seriously affect overall performance. The avoidance of such f
11、aults, on pit-wide systems, is extremely difficult. The generation of analogue signals within high voltage switchgear, and subsequent transmission for monitoring purposes, also presents difficulty in achieving the required degree of segregation between intrinsically safe and power circuits. A furthe
12、r disadvantage with analogue signals is that the simultaneous transmission of several signals requires either a multicore cable or separate cables. These disadvantages can largely be overcome if the analogue or state information is transmitted in the form of serially coded digital signals. With such
13、 signals complete galvanic isolation between the transmitting and receiving circuits is possible and, within wide limits, only two wires are required for transmission in each direction irrespective of the volume of data. If full benefit of digital signal data transmission is to be realized it is imp
14、ortant that transmission systems of different manufacture conform to a common electrical standard and operate in a uniform manner with identical procedure (or protocol) for handling the data. This standard aims to promote such conformity. It specifies relevant requirements for a low speed digital si
15、gnal link comprising a master and one or more slaves which interconnects the intrinsically safe circuits of one item of apparatus and the intrinsically safe circuits of other apparatus in such a way that units of different manufacture can be interchangeably coupled at the transmission line terminals
16、. This standard is published in three Parts as follows: Part 1: Specification for optical coupling; Part 2: Specification for transformer coupling; Part 3: Specification for message protocols. Parts 1 and 2 of this standard offer alternative methods of achieving galvanic isolation between the intrin
17、sically safe circuits of interconnected apparatus, but the two methods are not compatible. This Part of this standard specifies a600bits/s transmission system which employs optical coupling as the means of achieving galvanic isolation. A system will comprise a master and from1to8slaves connected in
18、point-to-point or multi-drop modes, with two cable conductors being used for each direction of transmission. Transmission from the master to a slave is achieved by the master acting as a switched current source which activates a light emitter at each slave. Transmission from slave to master is achie
19、ved by the master acting as both a current source, which is switched at the slave by a light dependent device, and a current monitor which senses the switched current.BS6556-1:1985 BSI 10-1999 iii Part 2 of this standard specifies a600bits/s transmission system which employs transformer coupling as
20、the means of achieving galvanic isolation. A system will comprise a master and from1to15slaves connected in point-to-point or multi-drop modes. Transmission between master and slaves is achieved by frequency shift keying (FSK) techniques, one pair of cable conductors being used for each direction of
21、 transmission. Part 3 of this standard defines the message protocols to be used by systems complying with Parts1or2. It does not, however, place any restrictions on the application data contained in transmitted messages, although industry standards may exist to regulate this. It is envisaged that fo
22、r high voltage applications optical coupling will be employed due to the relative ease of meeting segregation requirements. The optical system, however, has a limit of8slaves and a range of2km while the transformer method has a greater range and can handle up to15slaves. For intermediate application
23、s either system may be suitable. In Parts 1 and 2 of this standard slaves are the physical interface between the transmission line and one or more addressable logical slaves specified in Part 3 of this standard. A British Standard does not purport to include all the necessary provisions of a contrac
24、t. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Attention is drawn to the Health and Safety at Work etc. Act1974, the Mines and Quarries Act1954, the Regulations made under thes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS655611985LOWSPEEDDIGITALSIGNALSFORUSEINCOALMINESSPECIFICATIONFOROPTICALCOUPLING 煤矿 低速 数字信号 部分 耦合 规范

链接地址:http://www.mydoc123.com/p-546109.html