BS 6447-1984 Specification for absolute and gauge pressure transmitters with electrical outputs《输出电量的绝对压力发送器与表压发送器规范》.pdf
《BS 6447-1984 Specification for absolute and gauge pressure transmitters with electrical outputs《输出电量的绝对压力发送器与表压发送器规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6447-1984 Specification for absolute and gauge pressure transmitters with electrical outputs《输出电量的绝对压力发送器与表压发送器规范》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS6447:1984 Incorporating Amendment No.1 Specification for Absolute and gauge pressure transmitters with electrical outputs UDC 621.316.79:531.787:532.11BS6447:1984 This British Standard, having been prepared under the directionof the Industrial-process Measurement and Control Stand
2、ards Committee, was published under the authority ofthe Board of BSI and comes intoeffect on 31January1984 BSI 07-1999 The following BSI references relate to the work on this standard: Committee reference PCL/1 Draft for comment 81/25629 DC ISBN 0 580 13649 3 Committees responsible for this British
3、Standard The preparation of this British Standard was entrusted by the Industrial-process Measurement and Control Standards Committee (PCL/-) to Technical Committee PCL/1 upon which the following bodies were represented: British Gas Corporation British Industrial Measuring and Control Apparatus Manu
4、facturers Association (BEAMA) British Pressure Gauge Manufacturers Association Department of Energy, Gas Standards Electricity Supply Industry in England and Wales Energy Industries Council Engineering Equipment and Materials Users Association Institution of Gas Engineers National Coal Board Scienti
5、fic Instrument Manufacturers Association (BEAMA) STC Water Regulations and Fittings Scheme The following bodies were also represented in the drafting of the standard, through subcommittees and panels: British Valve Manufacturers Association Ltd Department of Trade and Industry Department of Trade an
6、d Industry, National Physical Laboratory Department of Trade and Industry, National Engineering Laboratory Metals Society Ministry of Defence Sira Limited Amendments issued since publication Amd. No. Date of issue Comments 5223 September 1986 Indicated by a sideline in the marginBS6447:1984 BSI 07-1
7、999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Classification 1 4 Performance 2 5 Materials and construction 4 6 Marking 5 Annex A Methods of test 6 Table 1 Limits of combined error 2 Table 2 Limits of zero shift and span change with temperature
8、, andlimitsofresidual changes after temperature excursions 2 Table 3 Over-range pressure 4 Table 4 Limits of average long-term drift 4 Table 5 Atmospheric conditions for reference measurements 6 Table 6 Frequency ranges for evaluation 9 Publications referred to Inside back coverBS6447:1984 ii BSI 07
9、-1999 Foreword This British Standard has been prepared under the direction of the Industrial-process Measurement and Control Standards Committee. The SI pressure unit “pascal” has been used throughout this standard. However, since a large sector of British industry is committed to the use of the pre
10、ssure unit “bar” and intends to maintain this position, the equivalent in bars has been given in brackets after the value in pascals. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. C
11、ompliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may ha
12、ve had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS6447:1984 BSI 07-1999 1 1 Scope This British Standard specifies requirements for d.c. powered electrical transmitters with analogue direct current output used in absolute and gauge pressure meas
13、urement. This specification applies to transmitters for general industrial use but does not apply to aerospace, marine, laboratory and medical requirements. NOTEThe titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this Bri
14、tish Standard the following definitions apply. 2.1 measured error the largest deviation of the output of the transmitter from its corresponding ideal value, obtained with both increasing and decreasing inputs NOTEMeasured error is expressed as a percentage of span and is determined in accordance wit
15、h the method described in A.2.2. 2.2 hysteresis that property of an element evidenced by the dependence of the, value of the output, for a given excursion of the input, upon the history of prior excursions and the direction of the current traverse NOTEThis is a common usage definition which includes
16、 hysteresis error and dead band. That portion of the difference which is dependent on the history of prior excursion is hysteresis error while that portion due to dead band may be determined by a conventional dead band test. 2.3 hysteresis error that portion of hysteresis due to energy absorption in
17、 the elements of a measuring instrument NOTEHysteresis error should be determined by subtracting the value of dead band from the maximum measured separation between upscale-going and downscale-going indications of the measured variable, during a full-range traverse unless otherwise specified. 2.4 de
18、ad band the largest change in input that can be effected without causing a detectable change of output 2.5 range the region between the limits within which a quantity is measured, received or transmitted, expressed by stating the lower and upper range values 2.6 lower range value the lowest value of
19、 the measured variable that a device is adjusted to measure 2.7 upper range value the highest value of the measured variable that a device is adjusted to measure 2.8 span the algebraic difference between the upper and lower range values 2.9 over-range the condition in which any value of the input si
20、gnal exceeds its upper range value or goes below its lower range value 2.10 repeatability the closeness of agreement among a number of consecutive measurements of the output for the same value of the input under the same operating conditions, approaching from the same direction, for full-range trave
21、rses 2.11 transmitter a measuring transducer whose output is a standardized signal 2.12 absolute pressure an indication of pressure based on a zero at total vacuum 2.13 gauge pressure an indication of pressure based on a zero at the ambient atmospheric pressure 3 Classification 3.1 General. The perf
22、ormance characteristics of transmitters are classified as follows: a) accuracy (see Table 1); b) temperature coefficient (see Table 2).BS6447:1984 2 BSI 07-1999 The performance characteristics shall be identified by a two-element code in the above order, followed by the range of the transmitter with
23、in which the characteristics apply. Example: 3.2 Adjustable range transmitters. For adjustable range transmitters the performance characteristics shall be identified by two-element codes as specified in 3.1 appropriate to ranges corresponding at least to the maximum and minimum spans. Example: 4 Per
24、formance 4.1 General. Reference conditions shall be as given in A.1. 4.2 Accuracy. When tested in accordance with the method described in A.2 the combined error given by the sum of the modulus of the measured error and the repeatability, under reference conditions shall not exceed the values given i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS64471984SPECIFICATIONFORABSOLUTEANDGAUGEPRESSURETRANSMITTERSWITHELECTRICALOUTPUTS 输出 电量 绝对 压力 发送 规范

链接地址:http://www.mydoc123.com/p-546046.html