《BS 6392-9-1983 Testing of ethanol for industrial use - Method for determination of permanganate time《工业用乙醇试验 第9部分 用高锰酸盐退色时间的方法来测定乙醇含量》.pdf》由会员分享,可在线阅读,更多相关《BS 6392-9-1983 Testing of ethanol for industrial use - Method for determination of permanganate time《工业用乙醇试验 第9部分 用高锰酸盐退色时间的方法来测定乙醇含量》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6392-9: 1983 Incorporating Amendment Nos. 1 and 2 Testing of ethanol for industrial use Part 9: Method for determination of permanganate time NOTEIt is recommended that this Part be read in conjunction with the information given in the “General introduction” published separately
2、as BS 6392-0. UDC 661.722:543.869BS6392-9:1983 This British Standard, having been prepared under the directionof the Chemicals Standards Committee, was published under the authority ofthe Board of BSI and comes intoeffect on 31August1983 BSI 10-1999 The Committees responsible for this British Standa
3、rd are shown inPart0. The following BSI references relate to the work on this standard: Committee reference CIC/4 Draft for comment 80/51209 DC ISBN 0 580 13375 3 Foreword This Part of BS 6392 is technically equivalent to ISO1388“Ethanol for industrial use Methods of test” Part12“Determination of pe
4、rmanganate time”, published in1981by the International Organization for Standardization (ISO). For ease of production, the text of ISO1388-12:1981,with the omission of the Annex, has been used for this British Standard. Some terminology and certain conventions are not identical with those used in Br
5、itish Standards; attention is drawn especially to the following. The comma has been used as a decimal marker. In British Standards it is current practice to use a full point on the baseline as the decimal marker. This standard describes a method only and should not be used as a specification definin
6、g limits of purity. Reference to the standard should indicate that the method of test used is in accordance with BS6392-9. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance w
7、ith a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1and2, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had ame
8、ndments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date of issue Comments 4945 March 1986 7764 June 1993 Indicated by a sideline in the marginBS6392-9:1983 BSI 10-1999 i Contents Page Foreword Inside front cover
9、 1 Scope and field of application 1 2 Definition 1 3 Principle 1 4 Reagents 1 5 Apparatus 1 6 Procedure 1 7 Expression of results 1 Publication referred to Inside back coverii blankBS6392-9:1983 BSI 10-1999 1 1 Scope and field of application This Part of BS6392describes a method for the determinatio
10、n of the permanganate time of ethanol for industrial use. NOTEThe title of the publication referred to in this standard is given on the inside back cover. 2 Definition permanganate time the number of minutes required, after adding2ml of0,2g/l potassium permanganate solution to50ml of the sample, for
11、 the colour to match that of a colour standard 3 Principle Addition to a test portion, under specified conditions, of potassium permanganate solution. Determination of the time taken for the colour of this test solution to match that of a cobalt(II) chloride and uranyl nitrate colour standard. 4 Rea
12、gents During the analysis, unless otherwise specified, use only reagents of recognized analytical grade, and distilled water or water of equivalent purity. 4.1 Potassium permanganate, 0,2g/l solution. Use water previously boiled for30min with sufficient dilute potassium permanganate solution to give
13、 a stable faint pink coloration. Cool the water before preparation of the solution. Prepare this solution immediately before use and protect it from light. 4.2 Cobalt(II) chloride and uranyl nitrate, colour standard. To 5 ml of a 50 g/l solution of cobalt(II) chloride hexahydrate (CoCl 2 .6H 2 O), a
14、dd7ml of a40g/l solution of uranyl nitrate hexahydrate UO 2 (NO 3 ) 2 .6H 2 O, and dilute with water to50ml. WARNING. Uranyl nitrate is radioactive and it is essential that appropriate precautions are taken. The use of uranyl nitrate is subject to the Ionizing radiations regulations SI1985, No. 1333
15、and any amendments thereof which are currently in force. Prepare this solution on the day of use. 5 Apparatus NOTEClean the glassware used so as to avoid any risk of contamination. Ordinary laboratory apparatus, and 5.1 Water bath, capable of being controlled at15 0,2 C. 5.2 Two matched cylinders, o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS639291983TESTINGOFETHANOLFORINDUSTRIALUSEMETHODFORDETERMINATIONOFPERMANGANATETIME 工业 乙醇 试验 部分 用高锰酸盐

链接地址:http://www.mydoc123.com/p-546014.html