BS 6290-3-1999 Lead-acid stationary cells and batteries - Specification for the flat positive plate type《铅-酸固定式电池和蓄电池 平阳极板式电池规范》.pdf
《BS 6290-3-1999 Lead-acid stationary cells and batteries - Specification for the flat positive plate type《铅-酸固定式电池和蓄电池 平阳极板式电池规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6290-3-1999 Lead-acid stationary cells and batteries - Specification for the flat positive plate type《铅-酸固定式电池和蓄电池 平阳极板式电池规范》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BRITISH STANDARD BS 6290-3:1999 Incorporat
2、ing Corrigendum No. 1 ICS 29.220.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Lead-acid stationary cells and batteries Part 3: Specification for the flat positive plate typeThis British Standard, having been prepared under the direction of the Electrotechnical Sector Com
3、mittee, was published under the authority of the Standards Committee and comes into effect on 15 October 1999 BSI 02-2000 First published, November 1986 Second edition, October 1999 The following BSI references relate to the work on this standard: Committee reference PEL/21 Draft for comment 96/2010
4、03 DC ISBN 0 580 33040 0 BS 6290-3:1999 Amendments issued since publication Amd. No. Date Comments 10838 Corrigendum No. 1 February 2000 Supersession details added to foreword Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committ
5、ee PEL/21, Secondary cells and batteries, upon which the following bodies were represented: British Industrial Truck Association British Telecommunications plc Electricity Association Electric Vehicle Association of Great Britain Lighting Industry Federation Ltd. Ministry of Defence Society of Briti
6、sh Battery Manufacturers Society of Motor Manufacturers and Traders Ltd. Co-opted membersBS 6290-3:1999 BSI 02-2000 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Materials and components 2 5 Performance 2 6 Type t
7、ests 3 7 Identification marks 3 Annex A (informative) Applications 4 Annex B (informative) Electromagnetic compatibility 4 Annex C (informative) Operational recommendations 4 Annex D (informative) Recharge characteristics 5 Annex E (informative) Operating characteristics 7 Annex F (normative) Additi
8、onal capacity tests 7 Bibliography 8 Figure D.1 Typical recharge characteristics of flat-plate cells using constant-current charging following a discharge at the 3 h rate 5 Figure D.2 Typical recharge characteristics of flat-plate cells using limited-voltage charging following a discharge at the 3 h
9、 rate 6 Table F.1 Final voltages at discharge rates between 1 h and 10 h 7 Table F.2 Final voltages at discharge rates faster than 1 h 7ii BSI 02-2000 BS 6290-3:1999 Foreword This part of BS 6290 has been prepared by Technical Committee PEL/21. This British Standard is part 3 of a series of standard
10、s. It specifies requirements for flat-plate cells and batteries with pasted positive plates. It supersedes BS 6290-3:1986 which is withdrawn. BS 6290-1 has been withdrawn, having been superseded jointly by BS 6290-2:1999, BS 6290-3:1999, BS 6290-4:1997 and BS EN 60896-1:1992. BS 6290-2 specifies req
11、uirements for lead-acid high-performance Plante plate cells and batteries. BS 6290-4 specifies the criteria for classifying lead-acid valve-regulated cells and batteries. BS EN 60896-1 specifies general requirements for all free-venting types of stationary lead-acid cells and batteries. Guidance on
12、safety and health aspects of the handling, installation, usage and maintenance of lead-acid stationary cells and batteries is given in BS 6133. Annexes designated normative are part of the body of the standard. A British Standard does not purport to include all the necessary provisions of a contract
13、. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 8, an inside back cover
14、and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. BSI 02-2000 1 BS 6290-3:1999 1 Scope This part of BS 6290 specifies requirements for the materials and performance of stationary cells and batteries comprising either individual lead-ac
15、id cells or monobloc units of the flat-plate type. NOTE Information on applications is given in annex A. Annex B clarifies the position of these cells and batteries with respect to electromagnetic compatibility. 2 Normative references The following normative documents contain provisions which, throu
16、gh reference in this text, constitute provisions of this part of this British Standard. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. For undated references, the latest edition of the publication referred to applies. BS 6133:1995, Code of pr
17、actice for safe operation of lead-acid stationary batteries. BS 6334:1983, Methods of test for the determination of the flammability of solid electrical insulating materials when exposed to an igniting source. BS EN 60896-1, Stationary lead-acid batteries General requirements and methods of test Par
18、t 1: Vented types. 3 Terms and definitions For the purposes of this part of BS 6290, the terms and definitions given in BS 6133:1995, 1.3.2 apply, together with the following. 3.1 stationary cell cell that is installed on a fixed site and is not intended to be moved continually during its life 3.2 s
19、tationary battery two or more stationary cells electrically connected in series 3.3 lead-acid cell cell in which the electrolyte is dilute sulfuric acid, and which is fitted with plates in which the active materials are: a) positive electrode: lead dioxide; b) negative electrode: spongy lead 3.4 fre
20、e-venting enclosed cell cell that is fitted with a vent plug which allows free venting of electrolysis gas NOTE Provision is made for the addition of water and for measurement of the level and density of electrolyte. The cover is not intended to be readily removable. 3.5 flat-plate cell free-venting
21、 enclosed cell containing flat pasted positive and negative plates 3.6 container box in which plate groups and separators are assembled 3.7 group bar bar to which a plate or group of plates is attached 3.8 vent plug plug, provided with a gas vent or vents and baffled to arrest acid spray, that is fi
22、tted in the vent hole in the cover of an enclosed cell NOTE A vent plug normally also provides access for filling. 3.9 monobloc battery in which the cells are fitted in a multi-compartment container 3.10 float operation of a cell or battery in parallel with a load and a charging source at constant v
23、oltage 3.11 discharge taking out of a quantity of electricity from a cell by connecting it to an external circuit in such a way that the current flows through the cell in the reverse direction to that for charging NOTE The quantity of electricity taken out is usually measured in ampere hours. 3.12 c
24、apacity quantity of electricity that can be taken from a cell (or battery) at a particular rate of discharge, under specified conditions of voltage and temperature NOTE Capacity is usually measured in ampere hours. 3.13 rated capacity designation, by the manufacturer, of the capacity of a cell (or b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS629031999LEADACIDSTATIONARYCELLSANDBATTERIESSPECIFICATIONFORTHEFLATPOSITIVEPLATETYPE 固定 电池 蓄电池 平阳 极板

链接地址:http://www.mydoc123.com/p-545907.html