BS 6262-3-2005 Glazing for buildings - Code of practice for fire security and wind loading《建筑物门窗玻璃 防火、安全性和风力载荷的实施规范》.pdf
《BS 6262-3-2005 Glazing for buildings - Code of practice for fire security and wind loading《建筑物门窗玻璃 防火、安全性和风力载荷的实施规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6262-3-2005 Glazing for buildings - Code of practice for fire security and wind loading《建筑物门窗玻璃 防火、安全性和风力载荷的实施规范》.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58ICS 81.040.20Glazing for buildings Part 3: Code of practice for fire, security and wind loadingBRIT
2、ISH STANDARDBS 6262-3:2005BS 6262-3:2005This British Standard was published under the authority of the Standards Policy and Strategy Committee on 18 October 2005 BSI 18 October 2005First published as BS 973, 1941Second edition 1945Third edition, as CP 152, January 1960Fourth edition, August 1966 Fif
3、th edition, July 1972Sixth editiion, as BS 6262, June 1982Seventh edition, as BS 6262-3, October 2005The following BSI references relate to the work on this British Standard:Committee reference B/520/4ISBN 0 580 46773 2British Woodworking FederationConsumer Policy Committee of BSICouncil for Alumini
4、um in BuildingFlat Glass Manufacturers AssociationGlass and Glazing FederationNottingham UniversityOffice of the Deputy Prime Minister Building DivisionOffice of the Deputy Prime Minister represented by the BRE RICS Building Control ForumCo-opted membersAmendments issued since publicationAmd. No. Da
5、te CommentsCommittees responsible for this British StandardThe preparation of this British Standard was entrusted by Technical Committee B/520, Glass and glazing in building, to Subcommittee B/520/4, Properties and glazing methods, upon which the following bodies were represented:British Adhesives a
6、nd Sealants AssociationBritish Plastics FederaationBS 6262-3:2005 BSI 18 October 2005ContentsPageCommittees responsible Inside front coverForeword ii1Scope 12 Normative references 13 Terms and definitions 24Fire 55 Security 96 Wind loading 11Annex A (normative) Derivation of the design wind pressure
7、 in Table 7 32Annex B (informative) Examples of calculations of thickness required 33Bibliography 34Figure 1 Definition of size 4Figure 2 Basic wind speed map 13Figure 3 Topographic zones 14Figure 4 Float glass wind load resistance 16Figure 5 Toughened glass wind load resistance 17Figure 6 Laminated
8、 glass wind load resistance 18Figure 7 Patterned glass and wired glass wind load resistance 19Figure 8 Float glass insulating units wind load resistance 20Figure 9 Toughened glass insulating units wind load resistance 21Figure 10 Various insulating units wind load resistance 22Figure 11 Various insu
9、lating units wind load resistance 23Figure 12 Wind loading graph for plastics glazing sheet materials, 15 mm edge cover, aspect ratio 1.0 to 1.5 26Figure 13 Wind loading graph for plastics glazing sheet materials, 15 mm edge cover, aspect ratio greater than 1.5 up to and including 2.5 27Figure 14 Wi
10、nd loading graph for plastics glazing sheet materials, 15 mm edge cover, aspect ratio greater than 2.5 up to and including 3.5 28Figure 15 Wind loading graph for plastics glazing sheet materials, 5 mm edge cover, aspect ratio 1.0 to 1.5 29Figure 16 Wind loading graph for plastics glazing sheet mater
11、ials, 5 mm edge cover, aspect ratio greater than 1.5 up to and including 2.5 30Figure 17 Wind loading graph for plastics glazing sheet materials, 5 mm edge cover, aspect ratio greater than 2.5 up to and including 3.5 31Table 1 British and European Standards 5Table 2 Fire properties of glass (excludi
12、ng fire resistance) 7Table 3 Fire properties of integrity only glass when tested in accordance with BS 476-22:1987 and glazed in suitably designed systems 8Table 4 Fire properties of insulated glass when tested in accordance with BS 476-22:1987 and glazed in suitably designed systems 8Table 5 Fire p
13、roperties of plastics glazing sheet materials 9Table 6 Site terrain categories 11Table 7 Design wind loading at sea level 12Table 8 Topographical factor 14Table 9 Shape factors 15Table A.1 Building factors 32iBS 6262-3:2005iisupersedes BS 6262:1982, which will be withdrawn upon publication of all se
14、ven parts of the newly revised and restructured BS 6262.BS 6262:1982 is being revised and also restructured to simplify its use and will be published in seven parts: Part 1: General methodology for the selection of glazing; Part 2: Code of practice for heat, light and sound; Part 3: Code of practice
15、 for fire, security and wind loading; Part 4: Code of practice for safety related to human impact; Part 5: Code of practice for frame design considerations; Part 6: Code of practice for special applications; Part 7: Code of practice for provision of information.Requirements for standards of workmans
16、hip for glazing have been published separately as BS 8000-7 and, therefore, this subject is not dealt with in this standard.Since the correct selection of materials to be used in glazing for buildings depends on many factors, the recommendations in this part of the standard should be used in conjunc
17、tion with those in the other parts.As a code of practice, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading.This publication does not p
18、urport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.In particular, attention is drawn to the following statutory regulations.The Building Regulatio
19、ns 2000 1.The Building Regulations (Northern Ireland) 2.The Building Standards (Scotland) Regulations 2004 3.Summary of pagesThis document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 35 and a back cover.The BSI copyright notice displayed in this document indicates when
20、 the document was last issued.ForewordThis part of BS 6262 has been prepared by Subcommittee B/520/4. It partially BSI 18 October 2005BS 6262-3:20051 ScopeThis part of BS 6262 gives information and recommendations for vertical glazing in the external walls and interiors of buildings, with respect to
21、 fire safety, security and wind loading.These recommendations apply only when the glass is installed in a glazing system specifically designed for the purpose.These recommendations do not apply to:a) patent glazing (see BS 5516-1);b) glass in non-vertical applications (see BS 5516-2)c) glazing for c
22、ommercial greenhouses (see BS 5502-21);d) glazing for domestic greenhouses.Requirements for standards of workmanship for glazing have been published separately as BS 8000-7 and, therefore, this subject is not dealt with in this standard.2 Normative referencesThe following referenced documents are in
23、dispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.BS 476-4, Fire tests on building materials and structures Part 4: Non-combustibility test f
24、or materials.BS 476-6, Fire tests on building materials and structures Part 6: Method of test for fire propagation for products.BS 476-7, Fire tests on building materials and structures Part 7: Method of test to determine the classification of the surface spread of flame of products.BS 476-20, Fire
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS626232005GLAZINGFORBUILDINGSCODEOFPRACTICEFORFIRESECURITYANDWINDLOADING 建筑物 门窗 玻璃 防火 安全性 风力 载荷 实施 规范

链接地址:http://www.mydoc123.com/p-545889.html