BS 6200-6 2-1990 Sampling and analysis of iron steel and other ferrous metals - Guidelines on atomic absorption spectrometric techniques - Recommendations for the application of fl.pdf
《BS 6200-6 2-1990 Sampling and analysis of iron steel and other ferrous metals - Guidelines on atomic absorption spectrometric techniques - Recommendations for the application of fl.pdf》由会员分享,可在线阅读,更多相关《BS 6200-6 2-1990 Sampling and analysis of iron steel and other ferrous metals - Guidelines on atomic absorption spectrometric techniques - Recommendations for the application of fl.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6200-6.2: 1990 Sampling and analysis of iron, steel and other ferrous metals Part 6: Guidelines on atomic absorption spectrometric techniques Section 6.2 Recommendations for the application of flame atomic absorption spectrometry in standard methods for the chemical analysis of i
2、ron and steelBS 6200-6.2:1990 This British Standard, having been prepared under the direction of the Iron and Steel Standards Policy Committee, was published under the authority of the Board of BSI and comes into effect on 28September1990 BSI 09-1999 The following BSI references relate to the work o
3、n this standard: Committee reference ISM/18 Draft announced in BSI News April 1989 ISBN 0580 18180 4 Foreword This Section of BS6200 has been prepared under the direction of the Iron and Steel Standards Policy Committee. It is based on Information Circular No.9 “Chemical analysis of ferrous material
4、s: Operational guidelines for the application of flame absorption spectrometry in standard methods for the chemical analysis of iron and steel”, published by the Commission of the European Communities. An additional appendix,Appendix E, provides further details and recommendations relating to the us
5、e of perchloric acid in flame atomic absorption spectrometric methods of analysis. The information inAppendix E is a result of investigations undertaken since Information Circular No.9 was published. In the Synopsis on page1, reference is made to a complementary Information Circular, No.8, the text
6、of which has been adopted unchanged in BS6200-6.1. Both Information Circular No.8 and Information Circular No.9 were prepared by the European Committee ECISS/TC20 “Methods of chemical analysis” with the active participation and approval of the UK. The recommendations given in these documents have al
7、so been adopted by ISO/TC17/SC1, “Steel Methods of determination of chemical composition”. Most of the European and ISO standards involving flame atomic absorption spectrometry produced by these two committees have been prepared in accordance with these recommendations. Many of these methods have be
8、en implemented as Subsections of BS6200-3. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations
9、. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 14, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the ins
10、ide front cover. Amendments issued since publication Amd. No. Date of issue CommentsBS 6200-6.2:1990 BSI 09-1999 i Contents Page Foreword Inside front cover 1 Introduction 1 2 Equipment 1 2.1 Radiation source 1 2.2 Atomization of the sample 2 2.2.1 Nebulization 2 2.2.2 Atomization with a flame 2 2.3
11、 The monochromator 3 2.4 The detector, signal processing system and display 3 3 Systematic and random errors 4 3.1 Systematic errors 4 3.1.1 Interferences 4 3.1.2 Errors as a result of curvature of the calibration graph 5 3.2 Random errors 5 4 Setting and checking of the atomic absorption spectromet
12、er 6 4.1 Sensitivity 6 4.2 Detection limit 6 5 Literature 7 Appendix A Instrumental settings and optimization of the Atomic AbsorptionSpectrometer 8 Appendix B Reporting of results 9 Appendix C Safety 10 Appendix D Directions for the determination of some instrument parameters 11 Appendix E The use
13、of perchloric acid in flame atomic absorption spectrometry 12 Publications referred to Inside back coverii blankBS 6200-6.2:1990 BSI 09-1999 1 Synopsis Flame atomic absorption spectrometry is playing an increasingly important role in the analysis of iron and steel. However, the quality of results at
14、tainable, including the sensitivity, the detection limit and the precision depends not only on the instrument used but also, and markedly, on its optimization. The present report considers the essential features of an atomic absorption system, identifies possible sources of error and gives verificat
15、ion procedures to ensure optimum performance. This document is intended to be the work of reference during the performance of individual standard methods. NOTEAttention is also drawn to Information Circular No8: Chemical analysis of ferrous materials: Recommendations for the drafting of standard met
16、hods of analysis employing flame atomic absorption spectrometry for the chemical analysis of iron and steel. 1 Introduction The introduction of flame atomic absorption spectrometry into the analysis of iron and steel has greatly facilitated the determination of many of the elements. Indeed, some det
17、erminations which were scarcely practicable by the older methods and subject to serious inaccuracies may now be determined with relative ease. Understandably, atomic absorption spectrometry is being increasingly adopted as the preferred procedure for many future standard methods of analysis. As in t
18、he case of molecular absorption spectrophotometry, atomic absorption spectrometry is a relative method of analysis which depends on a comparison of absorbance values with those obtained from a series of calibration solutions. Whereas in spectrophotometric methods, absorbance values are relatively in
19、dependent of the instrument used and the settings are not very critical, in atomic absorption spectrometry absorbances are influenced by many factors. Not only the slope of the calibration graph but also its curvature, the random and systematic errors, the detection limit and the occurrences of inte
20、rferences are dependent on the instrument and on its many variables. This means that sample and calibration solutions have to be measured under identical conditions and that much care has to be exercised in the correct setting and regular checking of the instrument. The successful application of ato
21、mic absorption spectrometry in standard methods therefore depends on defining the operational parameters and achieving them in practice. The differences between available instruments implies that specific operational settings may vary from one to another. In order to meet the precision requirements
22、of the Standard methods, however, the equipment will have to satisfy certain performance criteria. These criteria and the appropriate adjustable variables of the equipment are discussed in the ensuing sections of this document. Parts of the spectrometer are also discussed where it is felt that unfam
23、iliarity with certain aspects may give rise to erroneous results. For general aspects of atomic absorption spectrometry, reference is made to ISO6955:1982, ISO/DIS6956:1981, and to the literature mentioned in section5. ECSC Working Group 20 is of the opinion that operational parameters cannot as yet
24、 be sufficiently well defined and controlled for flameless atomic absorption spectrometry to warrant its use in Standard methods. The present document is therefore confined to consideration of the flame technique. 2 Equipment 2.1 The radiation source For most elements, hollow cathode lamps are avail
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS6200621990SAMPLINGANDANALYSISOFIRONSTEELANDOTHERFERROUSMETALSGUIDELINESONATOMICABSORPTIONSPECTROMETRICTECHNIQUESRECOMMENDATIONSFORTHEAPPLICATIONOFFLPDF

链接地址:http://www.mydoc123.com/p-545863.html