BS 6043-2 11-1995 Methods of sampling and test for carbonaceous materials used in aluminium manufacture - Electrode coke - Determination of volatile matter content《制铝工业用炭素材料取样与试验方法.pdf
《BS 6043-2 11-1995 Methods of sampling and test for carbonaceous materials used in aluminium manufacture - Electrode coke - Determination of volatile matter content《制铝工业用炭素材料取样与试验方法.pdf》由会员分享,可在线阅读,更多相关《BS 6043-2 11-1995 Methods of sampling and test for carbonaceous materials used in aluminium manufacture - Electrode coke - Determination of volatile matter content《制铝工业用炭素材料取样与试验方法.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6043-2.11: 1995 ISO 9406:1995 Methods of sampling and test for Carbonaceous materials used in aluminium manufacture Part 2: Electrode coke Section 2.11 Determination of volatile matter content NOTEIt is recommended that this Section be read in conjunction with the general informa
2、tion in BS 6043-2.0, published separately.BS6043-2.11:1995 This British Standard, having been prepared under the directionof the Materials andSector Board, was publishedunder the authority ofthe Standards Board and comesinto effect on 15September1995 BSI 10-1999 1st edition August 1989 2nd edition S
3、eptember 1995 The following BSI references relate to the work on this standard: Committee reference CII/24 Draft for comment 87/53936 DC ISBN 0 580 24506 3 Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee CII/24, Raw mater
4、ials for the aluminium industry, upon which the following bodies were represented: Aluminium Federation British Ceramic Research Ltd. Chemical Industries Association Institute of Petroleum Refractories Association of Great Britain Amendments issued since publication Amd. No. Date CommentsBS6043-2.11
5、:1995 BSI 10-1999 i Contents Page Committees responsible Inside front cover National foreword ii 1 Scope 1 2 Normative references 1 3 Principle 1 4 Apparatus 1 5 Sampling and sample 2 6 Procedure 2 7 Expression of results 2 8 Test report 2 Figure 1 1 Figure 2 3 List of references Inside back coverBS
6、6043-2.11:1995 ii BSI 10-1999 National foreword This Section of BS6043has been prepared by Technical Committee CII/24 and is identical with ISO 9406:1995 Carbonaceous materials for the production of aluminium Green coke Determination of volatile matter content by gravimetric analysis, published by t
7、he International Standards Organization (ISO) and in the preparation of which the UK played a full part. This British Standard is a revision of BS 6043-2.11:1989 which is withdrawn. The main changes in this edition are revisions to Figure 1 and to clause 8. Part2of BS6043comprises the following seri
8、es of methods of test for electrode coke: With reference to 5.2, a sieve of nominal mesh aperture2504m complying with BS 410:1986 Specification for test sieves, may be used. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are resp
9、onsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Section Subject Identical with 2.1 Sampling ISO 6375 2.2 Ash content of green and calcined cokes ISO 8005 2.3 Ash analysis (AAS) no equivalent InternationalStandard 2.
10、4 Ash analysis (XRF) 2.5 Apparent density and porosity a 2.6 Density (xylene method) ISO 8004 2.7 Off content (gravimetric method) ISO 6997 2.8 Oil content (extraction method) ISO 8723 2.9 Sieve analysis a 2.10 Electrical resistivity a 2.11 Volatile matter content ISO 9406 2.12 Partical-size distrib
11、ution of fine coke (laserdiffraction method) no equivalent InternationalStandard a In preparation. Cross-references International Standard Corresponding British Standard BS ISO 5725 Accuracy (trueness and precision) of measurement methods and results ISO 5725-1:1994 Part 1:1994 General principles an
12、d definitions (Identical) ISO 5725-2:1994 Part 2:1994 Basic method for the determination of repeatability and reproducibility of a standard measurement method (Identical) ISO 6375:1980 BS 6043 Methods of sampling and test for carbonaceous materials used in aluminium manufacture Part 2 Electrode coke
13、 Section 2.1:1985 Sampling (Identical) Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indica
14、ted in the amendment table on the inside front cover.BS6043-2.11:1995 BSI 10-1999 1 1 Scope This International Standard specifies a method for the determination, by gravimetric analysis, of the volatile matter in green coke used in the production of aluminium. The method is applicable to green cokes
15、 having volatile matter contents greater than1% (m/m). 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, the editions indicated were valid. All standards are subje
16、ct to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. ISO 565:1990, Test
17、 sieves Metal wire cloth, perforated metal plate and electroformed sheet Nominal sizes of openings. ISO 5725-1:1994, Accuracy (trueness and precision) of measurement methods and results Part 1: General principles and definitions. ISO 5725-2:1994, Accuracy (trueness and precision) of measurement meth
18、ods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method. ISO 6375:1980, Carbonaceous materials for the production of aluminium Coke for electrodes Sampling. 3 Principle A test portion is heated in a crucible at a specified temp
19、erature and the loss in mass determined. The volatile matter content is then calculated as a percentage by mass. 4 Apparatus Ordinary laboratory apparatus, and 4.1 Silica crucibles, ten, undamaged, of mass10g to15g, with ground lids and with the dimensions shown in Figure 1. 4.2 Electric muffle furn
20、ace, with horizontal heating elements and capable of being maintained at a temperature of900 C 20 C, with useful heating chamber dimensions as follows: and with a central opening in the door to allow a thermocouple to be inserted. 4.3 Temperature-measuring device, with thermo-couple, range0 C to1000
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS60432111995METHODSOFSAMPLINGANDTESTFORCARBONACEOUSMATERIALSUSEDINALUMINIUMMANUFACTUREELECTRODECOKEDETERMINATIONOFVOLATILEMATTERCONTENT

链接地址:http://www.mydoc123.com/p-545589.html