BS 5977-1-1981 Lintels - Method for assessment of load《门窗过梁 第1部分 载荷评定方法》.pdf
《BS 5977-1-1981 Lintels - Method for assessment of load《门窗过梁 第1部分 载荷评定方法》.pdf》由会员分享,可在线阅读,更多相关《BS 5977-1-1981 Lintels - Method for assessment of load《门窗过梁 第1部分 载荷评定方法》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5977-1:1981 Incorporating Amendment No. 1 Lintels Part 1: Method for assessment of load UDC 624.072.22.042:692.299BS5977-1:1981 This British Standard, having been prepared under the directionof the Elements and Components (of Diverse Materials) for Building Standards Committee, w
2、as published underthe authority of the Executive Board and comes intoeffect on 31 December 1981 BSI 01-1999 The following BSI references relate to the work on this standard: Committee reference ECB/36 Draft for comment 79/13060 DC ISBN 0 580 12486 X Cooperating organizations The Elements and Compone
3、nts (of Diverse Materials) for Buildings Standards Committee, under whose direction this British Standard was prepared, consists of representatives from the following: The organizations marked with an asterisk in the above list, together with the following, were directly represented on the Technical
4、 Committee entrusted with the preparation of this British Standard: Agrment Board* Health and Safety Executive Aluminium Federation Incorporated Association of Architects and Asbestos Cement Manufacturers Surveyors Association Limited Institute of Building Control Brick Development Association* Inst
5、itute of Quality Assurance British Ceramic Research Association Institution of Municipal Engineers British Hardware Federation Institution of Structural Engineers* British Plastics Federation Mastic Asphalt Council and Employers British Precast Concrete Federation Ltd.* Federation British Steel Indu
6、stry* National Council of Building Materials British Woodworking Federation Producers Consumer Standards Advisory Committee National Federation of Building Trades of BSI Employers Convention of Scottish Local Authorities National Federation of Roofing Contractors Department of the Environment (Build
7、ing Royal Institute of British Architects* Research Establishment, Princes Royal Institution of Chartered Surveyors* Risborough Laboratory) Scottish Development Department Department of the Environment (Housing Society of Chemical Industry and Construction) Timber Research and Development Department
8、 of the Environment (PSA)* Association Flat Glass Manufacturers Association Trades Union Congress Glass and Glazing Federation Aerated Autoclaved Concrete Products Greater London Council Association Institution of Building Control Officers Ltd. Aggregate Concrete Block Association North Wales Slate
9、Quarries Association British Precast Concrete Federation Ltd. Steel Lintel Manufacturers Association Department of the Environment (Building Zinc Development Association Research Establishment) Individual expert District Surveyors Association Amendments issued since publication Amd. No. Date of issu
10、e Comments 4796 April 1985 Indicated by a sideline in the marginBS5977-1:1981 BSI 01-1999 i Contents Page Cooperating organizations Inside front cover Foreword ii 1 Scope 1 2 References 1 3 Definitions 1 4 Basic principles 1 5 Limiting conditions 2 6 Loads 3 7 Assessment of load for lintel supportin
11、g wall without openings within the interaction zone 3 8 Assessment of load for lintel supporting wall with one or more openings within the interaction zone 3 9 Assessment of load for lintel directly supporting roof or point loads 3 Appendix A Use of assessed loads for design or selection of lintels
12、5 Figure 1 Load triangle and interaction zone 1 Figure 2 Dispersion of loads 2 Figure 3 Effect of openings above the lintel 4 Figure 4 Example showing the loads on lintel with floor, partition and opening over the lintel 5 Figure 5 Example showing the loads on lintels supporting walls 6 Table 1 Conv
13、ersion factors for determining equivalent UDLs from assessed UDLs 7 Table 2 Conversion factors for determining equivalent UDLs from point loads close to the lintel 7 Publications referred to Inside back coverBS5977-1:1981 ii BSI 01-1999 Foreword This British Standard has been prepared under the dire
14、ction of the Elements and Components (of Diverse Materials) for Building Standards Committee and covers the design and use of all types of lintel (up to4.5m in span) in masonry. This Part describes a method for assessing the load carried by lintels. Part 2: of this standard is a specification for pr
15、efabricated lintels. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages Thi
16、s document comprises a front cover, an inside front cover, pages i and ii, pages1 to 8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on theinside front cover.BS5977-1
17、:1981 BSI 01-1999 1 1 Scope This Part of BS5977 describes a method for assessing the load carried by lintels in masonry: a) where lintels span up to4.5m in single storey buildings and up to3.6m in two or three storey buildings in normal domestic use; and b) where no openings are wholly or partly wit
18、hin the load triangle (see3.2). Appendix A gives guidance on the use of assessed loads for design or selection of lintels, but does not cover assessment of the overall stability of the structure or the design of adjacent masonry. NOTEIt has been assumed in the drafting of this Part that the assessme
19、nt of load on a lintel is entrusted to chartered structural or civil engineers or other appropriately qualified persons, for whose guidance it has been prepared. The responsibility for providing adequate support for lintels and for compatibility between lintels and other parts of the supporting stru
20、cture rests with the designer responsible for the overall stability of the building. For guidance, see BS 5628-1. 2 References The titles of the standards publications referred to in this standard are listed on the inside back cover. 3 Definitions For the purposes of this British Standard, the follo
21、wing definitions apply. 3.1 lintel a beam spanning an opening in a wall 3.2 load triangle a45 triangle having1.1times the clear span of the lintel as its base (seeFigure 1) 3.3 interaction zone a zone outside the load triangle but within a60 triangle having1.1times the clear span of the lintel as it
22、s base (seeFigure 1) 3.4 application level the top surface of the lintel under consideration (seeFigure 1) 3.5 application length the length over which a load is distributed at the application level (seeFigure 2 andFigure 3) 3.6 equivalent uniformly distributed load (UDL) that uniformly distributed
23、load which gives the same bending moment at the centre of the span as the maximum bending moment anywhere in the span given by the actual loads 4 Basic principles 4.1 General. Experience has shown that, subject to the conditions given in4.2, it is safe to design a lintel to carry less than the sum o
24、f the applied loads and the weight of masonry immediately above the lintel. The remainder is dispersed through the masonry on either side of the lintel. Figure 1 Load triangle and interaction zoneBS5977-1:1981 2 BSI 01-1999 4.2 Assumptions. For the methods described in clauses7 and8, it is assumed t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS597711981LINTELSMETHODFORASSESSMENTOFLOAD 门窗 过梁 部分 载荷 评定 方法 PDF

链接地址:http://www.mydoc123.com/p-545522.html