《BS 5724-2 15-1989 Medical electrical equipment - Particular requirements for safety - Specification for capacitor discharge X-ray generators《医用电气设备 第2部分 安全性专门要求 第15节 电容器放电X射线发生器规范》.pdf》由会员分享,可在线阅读,更多相关《BS 5724-2 15-1989 Medical electrical equipment - Particular requirements for safety - Specification for capacitor discharge X-ray generators《医用电气设备 第2部分 安全性专门要求 第15节 电容器放电X射线发生器规范》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5724-2.15: 1989 IEC 601-2-15: 1988 Incorporating Amendment No. 1 Medical electrical equipment Part 2: Particular requirements for safety Section 2.15 Specification for capacitor discharge X-ray generators (Implementation of CENELEC HD395.2.15 S1) UDC 615.47:62-83:621.31 + 615+849
2、.114+621.313:613.647.614.825BS5724-2.15:1989 This British Standard, having been prepared under the directionof the Health CareStandards Policy Committee,waspublished underthe authorityof the BoardofBSI andcomes into effect on 31 October 1989 BSI 09-1999 The following BSI references relate to the wor
3、k on this standard: Committee reference HCC/75 Draft for comment 85/52864 DC ISBN 0 580 17627 4 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Health Care Standards Policy Committee (HCC/-) to Technical Committee HCC/75, upon which the
4、following bodies were represented: Association of X-ray Equipment Manufacturers (BEAMA Ltd) British Dental Association British Institute of Radiology British Society of Dental and Maxillofacial Radiology College of Radiographers Department of Health Institute of Physical Sciences in Medicine (Ipsm)
5、Society of X-ray Technology Amendments issued since publication Amd. No. Date of issue Comments 6989 April 1992 Indicated by a sideline in the marginBS5724-2.15:1989 BSI 09-1999 i Contents Page Committees responsible Inside front cover National foreword iv Section 1. General 1 Scope and object 1 1.1
6、 Scope 1 1.2 Object 1 1.3 Particular Standards 2 1.4 Environmental conditions 2 2 Terminology and definitions 2 2.12 Miscellaneous 2 3 General requirements 3 3.101 Conventional meanings of electrical quantities 3 3.102 Radiation quantities 3 4 General requirements for tests 3 4.1 Type tests and rout
7、ine tests 3 4.10 Moisture pre-conditioning treatment 3 5 Classification 3 6 Identification, marking and documents 4 6.1 Marking on the outside of equipment or equipment parts 4 6.2 Marking on the inside of equipment or equipment parts 5 6.7 Indicator lights and push buttons 5 6.8 ACCOMPANYING DOCUME
8、NTS 5 7 Power input 8 Section 2. Safety requirements 8 Basic safety categories 8 9 Removable protective means 8 10 Special environmental conditions 8 11 Special measures with respect to safety 8 12 SINGLE FAULT CONDITION 8 Section 3. Protection against electric shock hazards 13 General 8 14 Requirem
9、ents related to classification 8 15 Limitation of voltage and/or current 8 16 Enclosures and PROTECTIVE COVERS 9 17 Insulation and PROTECTIVE IMPEDANCES 9 18 Earthing and potential equalization 9 19 Continous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS 9 19.3 Allowable values 9 20 Dielectric str
10、ength 10 20.3 Values of test voltages 10 20.4 Tests 10 Section 4. Protection against mechanical hazards 21 Mechanical strength 10 22 Moving parts 10 23 Surfaces, corners and edges 10 24 Stability and transportability 11 25 Expelled parts 11 26 Vibration and noise 11BS5724-2.15:1989 ii BSI 09-1999 Pa
11、ge 27 Pneumatic and hydraulic power 11 28 Suspended masses 11 Section 5. Protection against hazards from unwanted or excessive radiation 29 X-radiation 11 29.1 X-RADIATION generated by diagnostic CAPACITOR DISCHARGE X-RAY GENERATORS 11 30 Alpha, beta, gamma, neutron radiation and other particle radi
12、ation 13 31 Microwave radiation 13 32 Light radiation (including visual radiation and lasers) 13 33 Infra-red radiation 13 34 Ultra-violet radiation 13 35 Acoustical energy (including ultrasonics) 13 36 Electromagnetic compatibility 13 Section 6. Protection against hazards of explosions in medically
13、 used rooms 37 General 13 38 Classification, marking and ACCOMPANYING DOCUMENTS of ANAESTHETIC-PROOF EQUIPMENT 13 39 Common requirements for “AP” and “APG” equipment 13 40 Requirements and tests for ANAESTHETIC-PROOF EQUIPMENT, equipmentparts or components (AP) 14 41 Requirements and tests for ANAES
14、THETIC-PROOF CATEGORY G EQUIPMENT, equipment parts or components 14 Section 7. Protection against excessive temperatures, fire and other hazards,such as human errors 42 Excessive temperatures 14 42.1 Addition 14 42.5 Guards 14 43 Fire prevention 14 44 Overflow, spillage, leakage, humidity, ingress o
15、f liquids, cleaning, sterilization and disinfection 14 45 Pressure vessels and parts subject to pressure 14 46 Human errors 14 47 Electrostatic charges 14 48 Materials in APPLIED PARTS in contact with the body of the PATIENT 14 49 Interruption of the power supply 14 Section 8. Accuracy of operating
16、data and protection against incorrect output 50 Accuracy of operating data 15 50.1 Indication of electric and radiation output 15 50.101 Reproducibility of radiation output 15 50.102 Agreement between indicated and measured values of LOADING FACTORS 15 50.103 Correction for fluctuations of MAINS VOL
17、TAGE 16 50.104 Test conditions 16 50.105 General 17 50.106 Methods of measuring LOADING FACTORS 17 50.107 Conditions for measuring AIR KERMA 18BS5724-2.15:1989 BSI 09-1999 iii Page 50.108 Combination of LOADING FACTORS for the determination of COEFFICIENT OF VARIATION 19 50.109 Combination of LOADIN
18、G FACTORS for the determination of PER CENT AVERAGE ERROR 19 51 Protection against incorrect output 19 Section 9. Fault conditions causing overheating and/or mechanical damage;environmental tests 52 Fault conditions causing overheating and/or mechanical damage 20 53 Environmental tests 20 Section 10
19、. Constructional requirements 54 General 20 55 Enclosures and covers 20 56 Components and general assembly 20 56.8 Indicators 20 56.11 Switches 20 57 MAINS PARTS, components and layout 20 57.1 Separation from the SUPPLY MAINS 20 57.9 Mains supply transformers and MEDICAL ISOLATING TRANSFORMERS 21 57
20、.10 CREEPAGE DISTANCES and AIR CLEARANCES 21 58 PROTECTIVE EARTH TERMINALS 21 59 Construction and layout 21 59.4 Oil containers 21 Appendix AA Terminology 22 Appendix AA.2 Alphabetical index of English terms 22 Informative annex to HD 395.2.15 S1 Figure 101 TOTAL FILTRATION for the measurement of AI
21、R KERMA 18 Table 101 Permissible PER CENT AVERAGE ERROR of LOADING FACTORS 16 Publications referred to Inside back coverBS5724-2.15:1989 iv BSI 09-1999 National foreword This British Standard has been prepared under the direction of the Health Care Standards Policy Committee and is identical with IE
22、CPublication601-2-15:1988 “Medical electrical equipment” Part 2 “Particular requirements for the safety of capacitor discharge X-ray generators”, prepared by Technical Committee TC62 Electrical equipment in medical practice of the International Electrotechnical Commission (IEC). This Particular Stan
23、dard amends and supplements BS5724-1 hereinafter called the General Standard. As stated in1.3 of the General Standard, the requirements of this Particular Standard take precedence over those of the General Standard. This Section of BS5724 is also in agreement with Harmonization Document HD395.2.15S1
24、, published by the European Committee for Electrotechnical Standardization (CENELEC). As in the General Standard, the requirements are followed by compliance tests. The numbers of the sections and clauses in this standard refer to the related sections and clauses in the General Standard. Clauses, su
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS57242151989MEDICALELECTRICALEQUIPMENTPARTICULARREQUIREMENTSFORSAFETYSPECIFICATIONFORCAPACITORDISCHARGEXRAYGENERATORS

链接地址:http://www.mydoc123.com/p-545331.html