BS 5551-2 7-1988 Fertilizers - Sampling - Recommendations for minimum mass of increment of a solid fertilizer to be taken to be representative of the total sampling unit《肥料 第2部分 取样.pdf
《BS 5551-2 7-1988 Fertilizers - Sampling - Recommendations for minimum mass of increment of a solid fertilizer to be taken to be representative of the total sampling unit《肥料 第2部分 取样.pdf》由会员分享,可在线阅读,更多相关《BS 5551-2 7-1988 Fertilizers - Sampling - Recommendations for minimum mass of increment of a solid fertilizer to be taken to be representative of the total sampling unit《肥料 第2部分 取样.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5551-2.7: 1988 Fertilizers Part 2: Sampling Section 2.7 Recommendations for minimum mass of increment of a solid fertilizer to be taken to be representative of the total sampling unit UDC 631.8:543.05:620.113:531.422:06.052.6BS5551-2.7:1988 This British Standard, having been prep
2、ared under the directionof the Chemicals Standards Committee, was published under the authority ofthe Board of BSI and comes into effect on 30 September 1988 BSI 11-1999 The following BSI references relate to the work on this standard: Committee reference CIC/37 Draft for comment 87/53554 DC ISBN 0
3、580 16785 2 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Chemicals Standards Committee (CIC/-) to Technical Committee CIC/37, upon which the following bodies were represented: Association of Public Analysts Department of Trade and Ind
4、ustry (Laboratory of the Government Chemist) Fertiliser Manufacturers Association Ltd. Institute of Trading Standards Administration Ministry of Agriculture, Fisheries and Food Amendments issued since publication Amd. No. Date of issue CommentsBS5551-2.7:1988 BSI 11-1999 i Contents Page Committees r
5、esponsible Inside front cover Foreword ii 1 Scope and field of application 1 2 Basic theory 1 3 Fertilizers composed of particles of the same nature 1 4 Fertilizers composed of particles of different nature 2 5 General comment on the reduction of samples 3 6 Selection of the mass of the smallest inc
6、rement in the case of grouping of the increments 3 Annex Calculation of m 4 Table 1 Value of C in relation to number of dividing operations 2 Table 2 Examples of limit values of m 2 Table 3 Values of minimum mass for similar size distributions 2 Table 4 Values of minimum mass for size distribution w
7、hich vary greatly 3 Table 5 Values of minimum mass for two constituents with very different densities 3BS5551-2.7:1988 ii BSI 11-1999 Foreword This Section of BS5551 has been prepared under the direction of the Chemicals Standards Committee in order to provide recommendations for the minimum mass of
8、 increment to be taken to be representative of the total sampling unit when sampling a solid fertilizer. For some years the United Kingdom has participated in the standardization of methods of sampling fertilizers through Subcommittee2, Sampling, of Technical Committee134, Fertilizers and soil condi
9、tioners, of the International Organization for Standardization (ISO). As international agreement is reached on the methods, it is proposed to publish them as Sections of BS5551. The standard is published in four Parts, each Part being subdivided into Sections and, where appropriate, Subsections. The
10、 four Parts are: Part 1: Terminology and labelling; Part 2: Sampling; Part 3: Physical properties; Part 4: Chemical analysis. This Section of Part2is identical with ISO/TR7553:1987 “Fertilizers Sampling Minimum mass of increment to be taken to be representative of the total sampling unit”. This docu
11、ment has been published by ISO as a type3technical report, which is a document containing information in a form different from that usually published in International Standards. In this case the document contains some of the theoretical background to the derivation of formulae for calculating the mi
12、nimum mass of an increment and gives examples of values in tables. This document complements other standards for sampling fertilizers, both published and in course of preparation. For ease of production the text of the international technical report has been used for this British Standard. Some term
13、inology and certain conventions are not identical with those used in British Standards; attention is drawn especially to the following. The comma has been used as a decimal marker. In British Standards it is current practice to use a full point on the baseline as the decimal marker. The symbol “ml”
14、has been used to denote millilitre. In British Standards it is current practice to use the symbol “mL”. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Stand
15、ard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 5 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indic
16、ated in the amendment table on the inside front cover.BS5551-2.7:1988 BSI 11-1999 1 1 Scope and field of application When sampling is carried out on a batch of fertilizer, an increment is taken from N units. Each of these increments may be taken either by means of partial sampling devices, if their
17、validity (absence of any particular bias) is assured, or by treating the complete item with a suitable reduction device (absence of bias). This British Standard specifies, for the latter case, the extent of mass reduction beyond which the error in the representativity of the increment can no longer
18、be ignored. It may also be used to establish the minimum mass of any intermediate increment during the treatment of the sample, up to analysis. Where partial sampling devices are used, this limiting mass can be much more important. 2 Basic theory Taking into account the granular nature of solid fert
19、ilizers, the sampled mass cannot be reduced indefinitely without losing all representativity. However, it is possible to relate the mass of the sample to a minimum error of representativity, as a function of the variability in composition of the product sampled and of its particle size distribution.
20、 Emphasis should, however, be placed on the nature of the minimum limit value of this error to which can, in practice, be added large errors due to the variability of the increments, often associated with defective sampling devices (spears in particular). It should also be noted that this error occu
21、rs at each reduction operation on the sample after its constitution. Particular attention is drawn to the fact that, in preparing the test portion from the laboratory sample, representativity can easily be lost if the masses sampled at a given point are insufficient with respect to particle size dis
22、tribution and variability in composition or if they do not follow the rule of equiprobability of choice. This concept is, in fact, empirically admissible because, in the case of determinations where grinding is allowed, such an operation is generally carried out before the test portion is taken. Sta
23、tistical studies now make it possible to calculate accurately a relation between these magnitudes. In cases where grinding is not possible (for example determination of particle size distribution), they also enable a relationship to be obtained between the mass of the test portion and the error of r
24、epresentativity. Two types of fertilizer may be encountered: a) Fertilizer in which all the particles are essentially of the same nature Once the variability in analysis from one particle to another is known, it is possible to calculate statistically, on the basis of a normal distribution, the numbe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS5551271988FERTILIZERSSAMPLINGRECOMMENDATIONSFORMINIMUMMASSOFINCREMENTOFASOLIDFERTILIZERTOBETAKENTOBEREPRESENTATIVEOFTHETOTALSAMPLINGUNIT

链接地址:http://www.mydoc123.com/p-545221.html