BS 5350-B5-1976 Methods of test for adhesives - Determination of gelation time《粘合剂试验方法 第B5部分 胶凝时间的测定》.pdf
《BS 5350-B5-1976 Methods of test for adhesives - Determination of gelation time《粘合剂试验方法 第B5部分 胶凝时间的测定》.pdf》由会员分享,可在线阅读,更多相关《BS 5350-B5-1976 Methods of test for adhesives - Determination of gelation time《粘合剂试验方法 第B5部分 胶凝时间的测定》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5350-B5: 1976 Incorporating Amendment No. 1 Methods of test for Adhesives Part B5: Determination of gelation time UDC 665.93:620.1 + 665.93:66.095.26 40BS5350-B5:1976 BSI 11-1999 ISBN 0 580 09103 1 Foreword Gelation time, as defined in clause3, is applicable to solvent-containing
2、 and solventless systems and provides a simple means of assessing the rate of polymerization or the efficiency of curing agents. Certain systems when fully cured may only develop very soft gels which break into lumps upon inversion of the tubes. Similar systems, at an earlier stage of polymerization
3、, will flow evenly and this difference in behaviour may provide an adequate criterion. With hot-melt adhesives, dwell time in the hot application equipment is important. A method for the determination of heat stability of hot-melt adhesives is given in BS5350-H1. A British Standard does not purport
4、to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover
5、, pages i and ii, page 1 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date Comments 5359 February 1987 Indicated by
6、 a sideline in the marginBS5350-B5:1976 BSI 11-1999 i Contents Page Foreword Inside front cover 1 Scope 1 2 References 1 3 Definition 1 4 Method 1: gelation time at 25 C of solvent-containing adhesives 1 5 Method 2: gelation time for solventless adhesives 1 6 Expression of results 1 7 Test report 1i
7、i blankBS5350-B5:1976 BSI 11-1999 1 1 Scope Two methods of test are specified in this Part. Method 1 has an arbitrary endpoint and is suitable for comparative and quality control purposes. Method 2 is suitable for solventless systems and corresponds to BS2782:Method 835C:1980. It can be used for hig
8、h-viscosity materials, which may contain a proportion of solvent. 2 References This Part makes reference to the following standards publications: BS 2782, Methods of testing plastics Method835CDetermination of gelation time of polyester and epoxide resins using a gel timer. BS 5350, Methods of test
9、for adhesives PartH1Determination of heat stability of hot melt adhesives in the application equipment . 3 Definition For the purposes of this Part, the following definition applies. gelation time the time taken for a two (or more) part system to form a gel of reproducible, but arbitrary, consistenc
10、y under standard conditions 4 Method 1: gelation time at 25 C of solvent-containing adhesives 4.1 Principle. The adhesive components are mixed at a specified temperature and maintained, in stoppered glass tubes, at an even temperature. The contents are examined at specified periods for evidence of f
11、low. 4.2 Apparatus 4.2.1 Constant-temperature bath (or oven) capable of being controlled at25 0.2 C. 4.2.2 Glass tubes of approximately150ml capacity and approximately35mm internal diameter, each fitted with an airtight stopper. 4.2.3 Timing device, accurate to1min or less. 4.3 Procedure. Bring the
12、individual components to a temperature of25 1 C and then mix in the proportions and manner described by the manufacturer. The proportions shall be accurate to within2.5% of those specified by the manufacturer. Unless the manufacturers instruction require otherwise, complete the addition and intermix
13、ing of the components in not less than60s and start the timing device as soon as the addition of the final component is completed. Place approximately75ml of the mixed adhesive into each of several of the glass tubes, fit the stoppers and place the tubes vertically in the water bath or oven(4.2.1),
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS5350B51976METHODSOFTESTFORADHESIVESDETERMINATIONOFGELATIONTIME 粘合剂 试验 方法 B5 部分 时间 测定 PDF

链接地址:http://www.mydoc123.com/p-545042.html