BS 5306-5 2-1984 Code of practice for fire extinguishing installations and equipment on premises - Halon systems - Halon 1211 total flooding systems《住宅灭火装置及设备 第5部分 哈朗(聚四氟乙烯)灭火系统 第2.pdf
《BS 5306-5 2-1984 Code of practice for fire extinguishing installations and equipment on premises - Halon systems - Halon 1211 total flooding systems《住宅灭火装置及设备 第5部分 哈朗(聚四氟乙烯)灭火系统 第2.pdf》由会员分享,可在线阅读,更多相关《BS 5306-5 2-1984 Code of practice for fire extinguishing installations and equipment on premises - Halon systems - Halon 1211 total flooding systems《住宅灭火装置及设备 第5部分 哈朗(聚四氟乙烯)灭火系统 第2.pdf(54页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5306-5.2: 1984 Code of practice for Fire extinguishing installations and equipment on premises Part 5: Halon systems Section5.2Halon1211 total flooding systems UDC 614.842.6:614.844.2BS 5306-5.2:1984 This British Standard, having been prepared under the directionof the Fire Stand
2、ards Committee, was published underthe authority ofthe BoardofBSI andcomes into effecton 28September1984 BSI08-1999 The following BSI references relate to the work on this standard: Committee referenceFSM/13 Draft for comment82/11026DC ISBN 0 580 13923 9 Committees responsible for this British Stand
3、ard The preparation of this British Standard was entrusted by the Fire Standards Committee (FSM/-) to Technical CommitteeFSM/13 upon which the following bodies were represented: Association of Metropolitan Authorities British Automatic Sprinkler Association British Fire Protection Systems Associatio
4、n Ltd. British Fire Services Association British Gas Corporation Chief and Assistant Chief Fire Officers Association Confederation of British Industry Department of the Environment (Building Research Establishment, Fire Research Station) Department of the Environment (Property Services Agency) Depar
5、tment of Health and Social Security Department of Transport (Marine Directorate) Electricity Supply Industry in England and Wales Engineering Equipment and Materials Users Association Fire Extinguishing Trades Association Fire Insurers Research and Testing Organization (FIRTO) Fire Offices Committee
6、 Fire Protection Association Greater London Council Health and Safety Executive Home Office Incorporated Association of Architects and Surveyors Institute of Petroleum Institution of Fire Engineers Institution of Gas Engineers Ministry of Defence National Coal Board Royal Institute of British Archit
7、ects Society of Fire Protection Engineers Society of Motor Manufacturers and Traders Limited United Kingdom Atomic Energy Authority Amendments issued since publication Amd. No. Date of issue CommentsBS5306-5.2:1984 BSI 08-1999 i Contents Page Committees responsible Inside front cover Foreword iii 0
8、Introduction 1 1 Scope 1 2 Definitions 1 3 Characteristics of Halon 1211 2 4 Planning 3 5 Contract arrangements 4 6 System design 4 7 System operation 6 8 Enclosure characteristics 7 9 System components 8 10 System design procedure 11 11 Maintenance 12 12 Safety 13 Appendix A Deep-seated fires 15 Ap
9、pendix B Examples of calculation of Halon 1211 quantity where there is natural ventilation 15 Appendix C Examples of calculation of Halon 1211 quantity where there is forced ventilation 17 Appendix D Example of design calculation for balanced system 18 Appendix E Example of design calculation for un
10、balanced system 22 Figure 1 Isometric diagram of Halon 1211 pressurized to25 bar at21 C 30 Figure 2 Isometric diagram of Halon 1211 pressurized to10.5 bar at21 C 31 Figure 3 Pressure drop against mass flow rate for Halon 1211 in galvanized steel pipes 32 Figure 4 Mass flow rate per unit area against
11、 nozzle pressure with Halon 1211/N 2for nozzle type A 33 Figure 5 Mass flow rate per unit area against nozzle pressure with Halon 1211/N 2for nozzle type B 34 Figure 6 Type A nozzle 35 Figure 7 Type B nozzle 35 Figure 8 Example of balanced system 36 Figure 9 Example of Halon 1211 mass flow rate agai
12、nst container pressure for balanced system 37 Figure 10 Example of unbalanced system 38 Figure 11 Example of Halon 1211 mass flow rate against container pressure for unbalanced system 39 Figure 12 Label to be displayed at manual control 40 Figure 13 Label to be displayed at entrances to hazard 41 Fi
13、gure 14 Extended mass flow rate of Halon1211 to maintain constant concentration in enclosures with openings 42 Figure 15 Initial amounts of Halon1211 to produce a2.5% (V/V) residual concentration in enclosures equipped for mechanical mixing 43 Figure 16 Initial amounts of Halon1211 to produce a5% (V
14、/V) residual concentration in enclosures equipped for mechanical mixing 43BS 5306-5.2:1984 ii BSI 08-1999 Page Figure 17 Initial amounts of Halon1211 to produce a7.5% (V/V) residual concentration in enclosures equipped for mechanical mixing 44 Figure 18 Time required for interface between effluxing
15、Halon 1211/air mixtures and influxing air to descend to the centre of enclosures not equipped for mixing 44 Table 1 Physical properties of Halon 1211 24 Table 2 Quality of Halon 1211 24 Table 3 Halon 1211 flame extinguishment concentrations 25 Table 4 Halon 1211 inerting concentrations 26 Table 5 Ha
16、lon 1211 total flooding quantity 27 Table 6 Pipes 27 Table 7 Maximum pipework spans 28 Table 8 Friction loss in screwed pipe fittings and valves 28 Table 9 Friction loss in welded pipe elbows 28 Table 10 Safety clearances to enable operation, inspection, cleaning, repairs, painting and normal mainte
17、nance work to be carried out 29 Publications referred to 46BS 5306-5.2:1984 BSI 08-1999 iii Foreword This Section of this British Standard has been prepared under the direction of the Fire Standards Committee. This British Standard constitutes Part 5-5.2 of the BS5306 series, the main title of which
18、 is: BS5306, Code of practice for fire extinguishing installations and equipment on premises. The other Parts of BS5306 are or will be: Part 1: Hydrant systems, hose reels and foam inlets (formerly CP402.101); Part 2: Sprinkler systems (formerly CP402.201); Part 3: Portable fire extinguishers for bu
19、ildings and plant (formerly CP 402-3); Part 4: Carbon dioxide systems; Part 5: Halon systems; Section5.1: Halon1301 total flooding systems; Section 5.3: Halon 1211 local application systems 1) ; Part 6: Foam systems 1) ; Part 7: Extinguishing powder systems 1) . Halon 1211 total flooding systems, wi
20、th which this Section of the standard is concerned, are designed to provide a piped or otherwise connected supply of Halon1211 for the extinction of fire by achieving a given extinguishing concentration throughout the protected volume. There is a need for dissemination of information on established
21、system design and this code of practice has been prepared to meet this need. Its recommendations are made in the light of the best technical data known to the committee at the time of writing, but since a wide field is covered it has been impracticable to consider every possible factor or circumstan
22、ce that might affect implementation of these recommendations. Accordingly, while the aim has been to give as full and helpful an account as possible of the background knowledge available within the stated scope of the document, the recommendations should be applied in practical situations with discr
23、etion and due regard to local circumstances. This British Standard calls for the use of substances and/or procedures that may be injurious to health if adequate precautions are not taken. It refers only to the technical suitability and does not absolve the user from legal obligations relating to hea
24、lth and safety at any stage. It has been assumed in the drafting of this British Standard that the execution of its provisions is entrusted to appropriately qualified and experienced people. A British Standard does not purport to include all the necessary provisions of a contract. Users of British S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS5306521984CODEOFPRACTICEFORFIREEXTINGUISHINGINSTALLATIONSANDEQUIPMENTONPREMISESHALONSYSTEMSHALON1211TOTALFLOODINGSYSTEMS

链接地址:http://www.mydoc123.com/p-545018.html