《BS 5285-1975 Specification - Performance of a c electric ventilating fans and regulators for non-industrial use《非工业用交流电风扇及调节器性能规范》.pdf》由会员分享,可在线阅读,更多相关《BS 5285-1975 Specification - Performance of a c electric ventilating fans and regulators for non-industrial use《非工业用交流电风扇及调节器性能规范》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、I BSI BS*5285 75 m lb2Libb9 OLiL5L 9 I nlAll I UDC 644.1 : 697.953 : 621.63-83 ion iuu BS 5285 : 1975 Specification Performance of a.c. electric ventilating fans and regulators for non-industrial use 0 I Performances des ventilateurs et rgulateurs lectriques en courant alternatif pour usages non-ind
2、ustriels Leistungen fr Wechselstromventilatoren und Regler fr nichtindustrielle Zwecke British Standards Institution Gr 3 Contents Foreword Co-operating organizations Specification 1. Scope 2. References 3. Definitions 4. Impellers 5. Radio interference suppression 6. Speed regulators 7. Noise level
3、 8. Marking 9. Tests IO. Tolerances on ratings BSI BSm52B5 75 Lb2Libb4 0373520 5 W Page Inside front cover Back cover Appendix A. Additional information to be supplied by the manufacturer 1 1 1 1 1 1 1 1 2 2 3 Foreword This British Standard has been prepared under the authority of the Electrical Ind
4、ustry Standards Committee and covers the performance of and corresponding methods of test for ventilating fans and regulators for non-industrial use of the type and size stated in the scope. The standard is related to IEC Publication 665 A.C. electric ventilating fans and regulators for household an
5、d similar purposes. Attention is drawn to the fact that the safety requirements for ventilating fans for household use are covered by BS 3456 Safety of household electrical appliances, Section 2.29 Ventilating fans. The safety of other ventilating fans is covered by BS 4934 Safety requirements for e
6、lectric fans and regulators. . BSI BSX5285 75 m Lb24bbS OLiL52L 7 m BS 5285 : 1975 British Standard Specification Performance of a.c. electric ventilating fans and regulators for non-industrial use 1. Scope This British Standard specifies the performance of and the corresponding methods of test for
7、ventilating fans for non- industrial use with impellers not exceeding 500 mm in diameter, driven by single-phase a.c. motors having a power consumption not exceeding 500 W including any associated regulators for use on single-phase a.c. circuits not exceeding 250 V. It covers the performance of vent
8、ilating fans for use in walls, windows, kitchens or for attachment to ducts etc. The standard also covers cooker hoods containing fans. 2. References The titles of the British Standards referred-to in this standard are listed on the inside back cover. 3. Definitions For the purposes of this British
9、Standard, the following definitions, in addition to those given in BS 3456 : Part 1, 3.1 Fans 3.1.1 ventilating fan. A fan intended to displace air either from one side of a partition to the other, or within a duct installed either on the fan inlet or on the fan outlet or both. 3.1.2 partition type
10、ventilating (type A) fan. A ventilating fan installed in or upon the aperture of a partition in order to displace air from one side of the partition to the other side, both the sides being free spaces. 3.1.3 free inlet ventilating (type 6) fan. A ventilating fan with a direct inlet from free space a
11、nd with ducted outlet. 3.1.4 free outlet ventilating (type C) fan. A ventilating fan with ducted inlet, and with direct outlet to free space. 3.1.5 fully ducted ventilating (type D) fan. A ventilating fan with ducted inlet and ducted outlet. 3.1.6 centrifugal fan. A fan in which the air leaves the i
12、mpeller in a direction substantially at right angles to its axis. 3.1.7 propeller fan. A fan in which the air leaves the impeller in a direction substantially parallel to its axis. 3.1.8 cross flow fan. A fan in which the air is caused to flow through the impeller in a direction substantially at rig
13、ht angles to its axis, both entering and leaving the impeller at its periphery. 3.2 Types of enclosures of motors and regulators 3.2.1 totally enclosed type. An enclosure which does not provide for circulation of air between the inside and outside of the case, but which is not necessarily air-tight.
14、 3.2.2 ventilated type. An enclosure in which the ventilation is not materially obstructed while the live and internal rotating parts are protected mechanically against accidental or careless contact: 3.3 rated air delivery. The normal working air delivery assigned to the fan by the maker. apply. 3.
15、4 rated pressure. That pressure at which the fan delivers rated air delivery. 3.5 rated frequency. The frequency assigned to the fan or regulator by the maker. 4. Impellers 4.1 The impellers of the ventilating fans shall be well balanced. The blades and blade carriers shall be securely fixed so that
16、 they do not loosen in operation. 4.2 Guards shall be fitted to fans where the fans are normally fitted in a position in wh-ich the blades would be easily accessible to the user. 5. Radio interference suppression Fans and regulators shall meet the relevant requirements of BS 800. 6. Speed regulators
17、 Fan regulators shall be capable of reducing the full speed of the fan at the specified test voltage by at least 25 % in the case of capacitor motors and 20 % in the case of shaded pole motors. 7. Noise level Precautions shall be taken in the manufacture of fans and regulators to ensure that the noi
18、se level at all speeds is subjectively acceptable. 8. Marking 8.1 Each fan shall be indelibly marked with at least-the following information additional to that specified in BS 3456 : Section 2.29. (a) Country of manufacture. (b) Rated air delivery at zero pressure (for partition type ventilating fan
19、s only). (c) Rated air delivery and rated pressure for duct type fans. (d) Rated voltage(s) or rated voltage range(s) in volts. (e) Symbol for nature of supply. (f) Rated frequency or rated frequency range. (9) Rated input in watts. (h) Makers name or trade mark. (i) Makers model or type reference.
20、(j) Symbol for degree of protection against moisture, if applicable. (k) Symbol for fans of class I I, if applicable. NOTE. It is recommended that the above information should also be marked on the associated regulator, if it is separate from the fan. 8.2 For additional information that the manufact
21、urer may be requested to supply, see appendix A. . - I A A When the voltage range is in excess of 10 % of the mean of the range BSI BS*5iB5 75 Lb24667 0171522 7 = When the voltage range is 10 % or less of the mean of the range BS 5285 : 1975 Air performance, power input and speed regulations 9. Test
22、s 9.1 General. The tests specified in this standard are type tests and are as follows: (a) speed regulators (clause 6) (b) air performance (9.3) (c) power input (9.2.2) . 9.2 Test voltage. The voltage at which the tests are conducted shall be in accordance with the following requirements. 9.2.1 When
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS52851975SPECIFICATIONPERFORMANCEOFACELECTRICVENTILATINGFANSANDREGULATORSFORNONINDUSTRIALUSE 工业 交流 电风扇

链接地址:http://www.mydoc123.com/p-545003.html