1、BRITISH STANDARD BS 5080-1: 1993 Structural fixings in concrete and masonry Part 1: Method of test for tensile loadingBS5080-1:1993 This British Standard, having been prepared under the directionof Technical CommitteeB/514, was publishedunder the authority ofthe Standards Board and comesinto effect
2、on 15 February 1993 BSI 02-1999 First published March 1974 Second edition February 1993 The following BSI references relate to the work on this standard: Committee reference B/514 Draft for comment 92/11949 DC ISBN 0 580 21604 7 Committees responsible for this British Standard The preparation of thi
3、s British Standard was entrusted by Technical Committee B/514, Access and support equipment, to Subcommittee B/514/41, Tests for fixings, upon which the following bodies were represented: Association of Building Component Manufacturers British Board of Agrement British Precast Concrete Federation Lt
4、d. Concrete Society Construction Fixings Association Department of the Environment Institution of Civil Engineers Institution of Structural Engineers London District Surveyors Association National Association of Scaffolding Contractors Stainless Steel Fabricators Association of Great Britain Suspend
5、ed Access Equipment Manufacturers Association Suspended Ceilings Association Amendments issued since publication Amd No. Date CommentsBS5080-1:1993 BSI 02-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 References 1 3 Definitions 1 4 Base materials 1 5 Installa
6、tion of fixing 6 6 Apparatus 7 7 Procedure 7 8 Presentation of results 8 9 Test report 8 Figure 1 Under cut anchors: alternative profiles of undercuts in thebasematerial 1 Figure 2 Types of fixing to show the dimensions required for reportingtheirdescription 3 Figure 3 A suitable form of loading app
7、aratus 9 List of references Inside back coverBS5080-1:1993 ii BSI 02-1999 Foreword This Part of BS 5080 has been prepared under the direction of Technical Committee B/514, Access and support equipment. This edition introduces technical changes but it does not reflect a full review or revision of the
8、 standard which will be undertaken in due course. It supersedes BS 5080-1:1974 which is withdrawn. The principle changes from the 1974 edition are as follows: a) a restriction has been added on the location of any reinforcement in the standard specimen; b) precautions have been included when using r
9、esin adhesives for bonding fixings; c) modifications have been made to the load application procedure; d) a new figure has been included to clarify the definition of an undercut anchor. This Part of BS 5080 describes a standard method for conducting tests under axial tensile forces on structural fix
10、ings installed in concrete or masonry materials used in building and civil engineering construction. Part 2 describes a standard method for conducting tests under shear forces on structural fixings. A structural fixing joins, supports or retains components, and is designed to resist some form of loa
11、ding since its failure will have structural significance. This method of test applies to fixings installed according to the suppliers recommended procedure in a solid base material. This test applies to the fixing assembly comprising the fixing and the base material and not just the fixing itself. F
12、ailure of a fixing assembly under an axial tensile force may be due to failure of the material from which the fixing was manufactured, failure of the base material in which it was installed or loss of adhesion between them. This test does not apply to fixings used in conjunction with woodscrews, e.g
13、.smallplugs of metal, plastics or fibrous composition, or fixings used with thin rigid sheet materials, e.g. walls, roofs, partitions, or cavity fixings for use with hollow clay or concrete block masonry. Displacement fixings (pins or studs inserted by a cartridge operated tool) are not included, as
14、 the method of test is not appropriate to their use. However, should a design demand structural considerations and testing, the procedures given in this standard should be followed as far as possible. The test does not cover fixings when used in timber. If this method of test is used for proof testi
15、ng the applied load and/or relative movement limits should be specified by the user. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of its
16、elf confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be i
17、ndicated in the amendment table on theinside front cover.BS5080-1:1993 BSI 02-1999 1 1 Scope This Part of BS 5080 specifies a method for conducting tests under axial tensile forces on structural fixings installed in concrete or masonry used in building and civil engineering. The test applies to the
18、following types of fixing installed in concrete, natural stone, cast stone or brick or block masonry. a) Expanding anchors. Anchors held in drilled holes by friction or wedging action. b) Bonded fixings. Fixings held in drilled holes by grout or other bonding material. c) Cast-in fixings. Anchor bol
19、ts and sockets cast into the material during construction. d) Channel inserts. Slots and channels cast into the material during construction. e) Undercut anchors. Anchors held in drilled holes by interlocking in under-reamed shapes formed during drilling or setting (see Figure 1). The two distinct s
20、ituations in which the test can be applied are as follows: 1) for comparative or reference purposes, for which a standard specimen of base material is specified in 4.1; 2) for a specific application, for which the base material should be appropriate to the intended use of the fixing. In this situati
21、on the base material may be either a specimen manufactured for the purpose or a representative section of the base material in place. 2 References 2.1 Normative references This Part of BS 5080 incorporates, by reference, provisions from specific editions of other publications. These normative refere
22、nces are cited at the appropriate points in the text and the publications are listed on the inside back cover. Subsequent amendments to, or revisions of, any of these publications apply to this Part of BS 5080 only when incorporated in it by updating or revision. 2.2 Informative references This Part
23、 of BS 5080 refers to other publications that provide information or guidance. Editions of these publications current at the time of issue of this standard are listed on the inside back cover, but reference should be made to the latest editions. 3 Definitions For the purposes of this Part of BS 5080
24、 the following definitions apply. 3.1 supplier person who supplies or sells the fixing, and who may be the manufacturer, a selling agent or retailer 3.2 user person who specifies the fixing for installation and who may be the architect, consulting engineer, contractor or subcontractor, according to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS508011993STRUCTURALFIXINGSINCONCRETEANDMASONRYMETHODOFTESTFORTENSILELOADING 混凝土 砖石 工程 结构 附件 部分 负荷 试验

链接地址:http://www.mydoc123.com/p-544849.html