《BS 4140-24-1987 Methods of test for aluminium oxide Determination of fine particle size distribution (method using electroformed sieves)《氧化铝试验方法 第24部分 粒度分布测定(电铸筛分法)》.pdf》由会员分享,可在线阅读,更多相关《BS 4140-24-1987 Methods of test for aluminium oxide Determination of fine particle size distribution (method using electroformed sieves)《氧化铝试验方法 第24部分 粒度分布测定(电铸筛分法)》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 4140-24: 1987 ISO 8220:1986 Methods of test for Aluminium oxide Part 24: Determination of fine particle size distribution (method using electroformed sieves) ISO title: Aluminium oxide primarily used for the production of aluminium Determination of the fine particle size distribu
2、tion (less than 60 4m) Method using electroformed sieves NOTEIt is recommended that this Part be read in conjunction with the general information given in BS4140-0 “General introduction” which is issued separately. UDC 661.862.22:620.168.32BS4140-24:1987 This British Standard, having been prepared u
3、nder the directionof the Chemicals Standards Committee, was published under the authorityofthe Board of BSIandcomes into effect on 30April1987 BSI 11-1999 The committees responsible for this British Standard are shown inPart 0 The following BSI references relate to the work on this standard: Committ
4、ee reference CIC/24 Draft for comment 84/53017 DC ISBN 0 580 15831 4 Amendments issued since publication Amd. No. Date of issue CommentsBS4140-24:1987 BSI 11-1999 i Contents Page National foreword ii 1 Scope and field of application 1 2 References 1 3 Principle 1 4 Reagents and materials 1 5 Apparat
5、us 1 6 Procedure 1 7 Expression of results 2 8 Cleaning of the sieves 2 9 Test report 2 Figure Typical agitation device for electroformed sieves 3 Publications referred to Inside back coverBS4140-24:1987 ii BSI 11-1999 National foreword This Part of BS4140 is identical with ISO8220:1986 “Aluminium o
6、xide primarily used for the production of aluminium Determination of the fine particle size distribution (less than60m) Method using electroformed sieves” published by the International Organization for Standardization (ISO). Terminology and conventions. The text of the International Standard has be
7、en approved as suitable for publication as a British Standard without deviation. Some terminology and certain conventions are not identical with those used in British Standards; attention is drawn especially to the following. The comma has been used as a decimal marker. In British Standards, it is c
8、urrent practice to use a full point on the baseline as the decimal marker. The symbol “l” has been used to denote litre. In British Standards it is current practice to use the symbol “L”. Wherever the words “International Standard” appear, referring to this standard, they should be read as “British
9、Standard”. The Technical Committee has reviewed the provisions of ISO3310-2:1982, to which reference is made in clause2, and has decided that they are acceptable for use in conjunction with this standard. A related British Standard for ISO3310-2 is BS410:1986 “Specification for test sieves”. This st
10、andard prescribes methods of test only, and should not be used or quoted as a specification defining limits of purity. Reference to this Partshould indicate that the method of test used complies with BS4140-24:1987. A British Standard does not purport to include all the necessary provisions of a con
11、tract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-references International Standard Corresponding British Standard BS 4140 Methods of test for aluminium oxide ISO 802:19
12、76 Part 1:1986 Preparation and storage of test samples (Identical) ISO 803:1976 Part 2:1986 Determination of loss of mass at300 C (Identical) Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 4, an inside back cover and a back cover. This standa
13、rd has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS4140-24:1987 BSI 11-1999 1 1 Scope and field of application This International Standard specifies a method for the determination of the particl
14、e size distribution (less than604m) of aluminium oxide primarily used for the production of aluminium, using electroformed sieves. NOTEThere is no correlation, for the calcined alumina, between the results obtained with the square-aperture and the round-aperture electroformed sieves. The use of eith
15、er kind of sieve should be clearly indicated in the compilation of the test report, as well as in the agreement protocols between suppliers and purchasers if the particle size distribution is indicated in the contract. 2 References ISO 802, Aluminium oxide primarily used for the production of alumin
16、ium Preparation and storage of test samples. ISO 803, Aluminium oxide primarily used for the production of aluminium Determination of loss of mass at300 C (conventional moisture). ISO 3310-2, Test sieves Technical requirements and testing Part 2: Test sieves of metal perforated plate. 3 Principle Qu
17、antitative separation by sieving of the particles in the range63to164m suspended in an aqueous solution of a dispersing agent. The sieves are square-aperture or round-aperture electroformed sieves, depending on their origin. Drying and weighing of each sieved fraction. 4 Reagents and materials Durin
18、g the analysis, use only reagents of recognized analytical grade and only distilled water or water of equivalent purity. 4.1 Sodium hexametaphosphate (NaPO 3 ) 6 , 1g/l solution. 4.2 Surface active agent, non-ionic polyethoxyl, saturated solution. 5 Apparatus Ordinary laboratory apparatus and 5.1 Ag
19、itation device, for the slow oscillation of the sieves (5.2) placed on a support, driven by a motor equipped with reduction gear and cam, capable of shaking the sieves with a frequency of1Hz and10mm amplitude. A schematic drawing is shown in the Figure. 5.2 Set of electroformed sieves, of maximal di
20、mensions75mm (available diameter65mm), mounted on stainless steel frames and fitted with a cloth for supporting the electroformed membrane. The sizes of the apertures shall be634532164m. The tolerances shall be those required by ISO3310-2. NOTEElectroformed sieves of80 and1004m are available. They m
21、ay be used with test portions of about2g. 5.3 Adjustable-height supports 5.4 Crystallization vessels, made of glass, diameter approximately125mm, height approximately65mm. 5.5 Funnel, made of polyethylene, diameter about90mm. 5.6 Vacuum device 5.7 Ultrasonic cleaner, (maximum power:100W). 5.8 Electr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS4140241987METHODSOFTESTFORALUMINIUMOXIDEDETERMINATIONOFFINEPARTICLESIZEDISTRIBUTIONMETHODUSINGELECTROFORMEDSIEVES

链接地址:http://www.mydoc123.com/p-544188.html