BS 3166-1959 Specification for thermographs (liquid-filled and vapour pressure types) for use within the temperature range -20 F to 220 F ( -30 C to 105 C)《温度范围为-20-220F(-30-105℃)用.pdf
《BS 3166-1959 Specification for thermographs (liquid-filled and vapour pressure types) for use within the temperature range -20 F to 220 F ( -30 C to 105 C)《温度范围为-20-220F(-30-105℃)用.pdf》由会员分享,可在线阅读,更多相关《BS 3166-1959 Specification for thermographs (liquid-filled and vapour pressure types) for use within the temperature range -20 F to 220 F ( -30 C to 105 C)《温度范围为-20-220F(-30-105℃)用.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 3166:1959 Specification for Thermographs (Liquid-filledand vapour pressure types) For use within the temperature range 20 F to 220 F (30 C to 105 C)BS3166:1959 This British Standard, having been approved by the InstrumentIndustry StandardsCommittee and endorsed by the Chairman of
2、 theEngineering Divisional Council, was published under theauthority of the General Council on 30November1959 BSI 12-1999 The following BSI references relate to the work on this standard: Committee references INE/4 andINE/4/7 Draft for comment CZ(INE) 3463 ISBN 0 580 34119 4 Co-operating organizatio
3、ns The Instrument Industry Standards Committee, under whose supervision this British Standard was prepared, consists of representatives from the following Government departments and scientific and industrial organizations: Association of Scientific Workers British Ceramic Research Association Britis
4、h Clock and Watch Manufacturers Association British Electrical and Allied Industries Research Association British Electrical and Allied Manufacturers Association* British Industrial Measuring and Control Apparatus Manufacturers Association* British Iron and Steel Federation* British Nautical Instrum
5、ent Trade Association British Railways, The British Transport Commission British Scientific Instrument Research Association* Council of British Manufacturers of Petroleum Equipment Electricity Council, the Generating Board and the Area Boards in England and Wales* Engineering Equipment Users Associa
6、tion* Gauge and Tool Makers Association Institute of Physics Institution of Chemical Engineers Institution of Electrical Engineers* Institution of Heating and Ventilating Engineers* Institution of Mechanical Engineers* Iron and Steel Institute Meteorological Office Ministry of Health Ministry of Hou
7、sing and Local Government Ministry of Supply* National Coal Board National Physical Laboratory (D.S.I.R.)* Oil Companies Materials Association* Radio Industry Council Scientific Instrument Manufacturers Association* Society of Instrument Technology Water-Tube Boilermakers Association The Government
8、departments and scientific and industrial organizations marked with an asterisk in the above list, together with the following, were directly represented on the Committee entrusted with the preparation of this British Standard: Admiralty Air Ministry British Coal Utilization Research Association Gas
9、 Council Ministry of Power Ministry of Works Physical Society Refrigerated Cargo Research Council Society of Chemical Industry Individual manufacturers and users Amendments issued since publication Amd. No. Date CommentsBS3166:1959 BSI 12-1999 i Contents Page Co-operating organizations Inside front
10、cover Foreword ii 1 Scope 1 2 Materials 1 3 Design and construction 1 4 Temperature range 1 5 Accuracy 1 6 Compensation 2 7 Lag 2 8 Testing 2 9 Marking 2 10 Packaging 3 Appendix A Precautions to be taken when the twin-pen instrument is to be used as a wet and dry bulb hygrograph 4 Appendix B Testing
11、 of thermographs 5 Appendix C Recommendations for despatch by manufacturer and subsequent movement by customer from site to site 5 Figure 1 Typical identification plate 3 Table 1 Maximum error in computed per cent relative humidity 5BS3166:1959 ii BSI 12-1999 Foreword This standard makes reference t
12、o the following British Standards: BS 1133, Packaging code. BS 1986, Dimensional features of measuring and control instruments and panels for industrial purposes. BS 2548, Wood wool for general packaging purposes. BS 2770, Recommendations for the pictorial marking of handling instructions for non-da
13、ngerous goods. This British Standard is one of a series prepared under the authority of the Instrument Industry Standards Committee at the request of the Temperature Measuring Instruments Sub-committee of the Joint Equipment Standardization Committee. It is intended to cover Service requirements for
14、 a distant reading thermograph, either as a wet and dry bulb hygrograph or as a twin (or single) dry bulb thermograph, as well as requirements for certain industrial and marine uses. For determining the relative humidity of the air the instrument is used as a wet and dry bulb hygrograph and the rela
15、tive humidity is calculated using the appropriate hygrometric tables 1)or slide rule 2) . When used as a hygrograph several precautions must be taken in order to obtain accurate results; these are discussed inAppendix A. These precautions must be taken if the performance of the instrument, as laid d
16、own in the body of this specification, is to be attained. NOTEWhere metric equivalents have been given, the figures in British units are to be regarded as the standard. The metric conversions are approximate. More accurate conversions should be based on the tables in BS350, “Conversion factors and t
17、ables”. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document co
18、mprises a front cover, an inside front cover, pages i and ii, pages1 to 6 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. 1) Meteorological Office booklet M.O. 265
19、, H.M.S.O., for non-aspirated wet bulbs with ventilation rates3 to6 ft/sec (1 to 2m/sec). Guide to current practice, Institution of Heating and Ventilating Engineers, 1959, for aspirated wet bulbs with ventilation rates greater than15ft/sec (5m/sec). 2) Meteorological Office humidity slide rule, for
20、 F or C, conforming to the current Meteorological Office specification.BS3166:1959 BSI 12-1999 1 1 Scope This British Standard relates to thermographs of the liquid-filled and vapour pressure types, suitable for general and marine use in the measurement of temperatures within the range 20 F to220 F
21、(30 C to105 C). The instrument comprises a single or twin-pen recorder with one or two capillary tubes and bulbs respectively. When one bulb is used as a wet bulb, acontainer for distilled water is provided. A louvred screen may be used to house the bulbs, but the screen is not specified in this Bri
22、tish Standard. 2 Materials The instrument shall be constructed of materials which have been selected so as to avoid the possibility of electrolysis and corrosion. The capillary tube shall be adequately protected against mechanical damage and corrosion by a sheath or sheaths of suitable material, the
23、 outer one of which may be of a plastics material. When the instrument is used as a hygrograph, the wick shall be capable of conducting from the reservoir a supply of distilled water sufficient to keep the surface of the wet bulb moist under all normal conditions. 3 Design and construction The therm
24、ograph shall preferably use one of the types of drum and chart described in BS1986 3) , thepreferred size of the drum being 126 mm in diameter and154mm high. If provision is made for a single drum to carry two charts, however, the drum height may be increased to308mm. The fixed spindle type of clock
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS31661959SPECIFICATIONFORTHERMOGRAPHSLIQUIDFILLEDANDVAPOURPRESSURETYPESFORUSEWITHINTHETEMPERATURERANGE20FTO220F30CTO105C

链接地址:http://www.mydoc123.com/p-543583.html