BS 3101-1986 Specification for control and interlock circuits primarily associated with flameproof restrained plugs and sockets for use in coal mines《主要用于煤矿与防爆式限动插头插座联用的控制电路和联锁电路规范.pdf
《BS 3101-1986 Specification for control and interlock circuits primarily associated with flameproof restrained plugs and sockets for use in coal mines《主要用于煤矿与防爆式限动插头插座联用的控制电路和联锁电路规范.pdf》由会员分享,可在线阅读,更多相关《BS 3101-1986 Specification for control and interlock circuits primarily associated with flameproof restrained plugs and sockets for use in coal mines《主要用于煤矿与防爆式限动插头插座联用的控制电路和联锁电路规范.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 3101:1986 Specification for Control and interlock circuits primarily associated with flameproof restrained plugs and sockets for use in coal mines UDC 681.5:621.316.541-213.34:622.822.3BS3101:1986 This British Standard, having been prepared under the directionof the Mining and Qu
2、arrying Requisites StandardsCommittee, was published under the authority ofthe Board of BSI and comes intoeffect on 31 December1986 BSI 08-1999 First published March 1959 First revision December 1986 The following BSI references relate to the work on this standard: Committee reference MQE/16 Draft f
3、or comment 85/74238 DC ISBN 0 580 15411 4 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Mining and Quarrying Requisites Standards Committee (MQE/-) to Technical Committee MQE/16, upon which the following bodies were represented: Associ
4、ation of British Mining Equipment Companies British Coal Health and Safety Executive Institution of Mining Electrical and Mining Mechanical Engineers National Union of Mineworkers Amendments issued since publication Amd. No. Date of issue CommentsBS3101:1986 BSI 08-1999 i Contents Page Committees re
5、sponsible Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Control circuit requirements 1 4 Control circuit connections 2 5 Component requirements 3 6 Control circuit requirements when a resistor proving system is provided 3 7 Interlock circuit requirements 3 Appendix A Associated controll
6、ed devices and systems 5 Appendix B Conditions under which the control and interlock circuitcanbeconsidered as intrinsically safe 5 Figure 1 Connections for remote control 2 Figure 2 Connections for local control 2 Figure 3 Connections for interlock circuits 4 Publication referred to Inside back cov
7、erBS3101:1986 ii BSI 08-1999 Foreword This revision of BS3101 has been prepared under the direction of the Mining and Quarrying Requisites Standards Committee and supersedes BS3101:1959, which is withdrawn. It continues to aid manufacturers in establishing standard characteristics and operating cond
8、itions for control circuits for use primarily in coal mines; it does this by specifying requirements for circuits and associated apparatus which are necessary to ensure that the components of the control units away from the supply and control unit (gate-end box) can be used with any such unit that h
9、as a circuit complying with this standard. This revision provides for local or remote control and now includes requirements for optional interlock circuits and resistor proving systems which will enhance the operational safety of the control circuit. This standard refers only to BS1259, since at the
10、 date of publication no comparable British Standard or European standard exists relative to control and interlock circuits. Attention is drawn to Appendix A, which recommends operational requirements for equipment using a control circuit complying with this standard. Attention is drawn to the Health
11、 2) 0.65V at125 C. d) The limits of forward voltage drop, specified inc) of this subclause, shall not be exceeded during the service life. NOTEThe service life will need to be the subject of agreement between the supplier and purchaser. e) At the ratings specified in a) and b) of this subclause, the
12、 rectifier shall be capable of continuous operation at any temperature between0 C and80 C and a relative humidity of up to100%, when enclosed in a robust, unventilated case. 6 Control circuit requirements when a resistor proving system is provided 6.1 General When a resistor proving system is provid
13、ed, the control circuit shall only operate when the control apparatus is connected in the correct sequence of OFFSTARTRUN. NOTE 1It is accepted that under certain conditions, e.g.restoration of power or operation of series connected contacts, it may only be necessary to move the switching device fro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS31011986SPECIFICATIONFORCONTROLANDINTERLOCKCIRCUITSPRIMARILYASSOCIATEDWITHFLAMEPROOFRESTRAINEDPLUGSANDSOCKETSFORUSEINCOALMINES

链接地址:http://www.mydoc123.com/p-543560.html