BS 2646-5-1993 Autoclaves for sterilization in laboratories Methods of test for function and performance《实验室高压灭菌釜 功能和性能试验方法》.pdf
《BS 2646-5-1993 Autoclaves for sterilization in laboratories Methods of test for function and performance《实验室高压灭菌釜 功能和性能试验方法》.pdf》由会员分享,可在线阅读,更多相关《BS 2646-5-1993 Autoclaves for sterilization in laboratories Methods of test for function and performance《实验室高压灭菌釜 功能和性能试验方法》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 2646-5: 1993 Autoclaves for sterilization in laboratories Part 5: Methods of test for function and performanceBS2646-5:1993 This British Standard, having been prepared under the directionof the Laboratory Apparatus Standards Policy Committee, was published underthe authority of t
2、he Standards Board and comes intoeffect on 15 March 1993 BSI 01-1999 The following BSI references relate to the work on this standard: Committee reference LBC/35 Draft for comment 91/53016 DC ISBN 0 580 21337 4 Committees responsible for this British Standard The preparation of this British Standard
3、 was entrusted by the Laboratory Apparatus Standards Policy Committee (LBC/-) to Technical Committee LBC/35, upon which the following bodies were represented: Association of British Health Care Industries Association of National Health Service Supplies Officers Association of Sterilizer and Disinfec
4、tor Equipment Manufacturers British Dental Trade Association Central Sterilising Club Department of Health Health and Safety Executive Infection Control Nurses Association Institute of Hospital Engineering Institute of Purchasing and Supply Institute of Sterile Services Management Joint Committee of
5、 Professional Nursing, Midwifery and Health Visiting Associations (England) Medical Sterile Products Association National Blood Transfusion Service Public Health Laboratory Service Regional Hospital Boards Engineers Association Royal College of Pathologists Royal Pharmaceutical Society of Great Brit
6、ain Society for General Microbiology Stainless Steel Fabricators Association of Great Britain The following bodies were also represented in the drafting of the standard, through subcommittees and panels: Association of Clinical Pathologists British Glass Manufacturers Confederation British Laborator
7、y Ware Association Copper Development Association Institute of Medical Laboratory Sciences Manufacturing Science Finance Ministry of Agriculture, Fisheries and Food Royal Association of British Dairy Farmers Society for Applied Bacteriology Amendments issued since publication Amd. No. Date CommentsB
8、S2646-5:1993 BSI 01-1999 i Contents Page Committees responsible Inside front cover Foreword ii Section 1. General 1.1 Scope 1 1.2 References 1 1.3 Definitions 1 1.4 Test instruments and gauges 1 Section 2. Tests for safe function 2.1 Safety valves 3 2.2 Tests on door interlocks 3 2.3 Tests on discha
9、rge of chamber contents 3 2.4 Tests on double door autoclaves 3 Section 3. Tests for performance 3.1 Instrument accuracy, steady state and operating cycle controls: performance tests 4 3.2 Liquids sterilization: performance test 4 3.3 Make-safe: performance tests 5 3.4 Equipment and glassware steril
10、ization performance tests 8 List of references Inside back coverBS2646-5:1993 ii BSI 01-1999 Foreword This Part of BS 2646 has been prepared under the direction of the Laboratory Apparatus Standards Policy Committee. It describes methods of testing the function and performance of laboratory autoclav
11、es specified in Part 1 of this standard. BS 2646 comprises several separate Parts. The other Parts of the standard are as follows. Part 1: Specification for design, construction, safety and performance; Part 2: Guide to planning and installation; Part 3: Guide to safe use and operation 1) ; Part 4:
12、Guide to maintenance. It is anticipated that autoclaves to which this standard applies will be used for the following processes: a) liquids sterilization; b) make-safe; c) equipment and glassware sterilization; and methods of test are described for each process. BS 2646-3 will describe the stages of
13、 each operating cycle, together with recommended times and temperatures for various processes and safety procedures. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a
14、British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 10, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendme
15、nts incorporated. This will be indicated in the amendment table on theinside front cover. 1) In preparation.BS 2646-5:1993 BSI 01-1999 1 Section 1 Section 1. General 1.1 Scope This Part of BS 2646 describes the methods of test used to verify compliance with the requirements for design, construction,
16、 safety and performance specified in BS 2646-1:1993. This standard covers laboratory autoclaves for the sterilization of goods and material which could be infected with organisms categorized as Hazard Group 1,2 or 3 2) . It does not cover autoclaves for use with material infected with organisms in H
17、azard Group 4, for which complete containment and sterilization of infected condensate is considered to be essential. This standard does not apply to sterilizers or disinfectors used for medical, dental, pharmaceutical or veterinary purposes which are directly concerned with patient care, or those u
18、sed for fabrics subjected to sterilization which are required to be dry at the end of the cycle. These are covered by BS 3970. 1.2 References 1.2.1 Normative references This Part of BS 2646 incorporates, by reference, provisions from specific editions of other publications. These normative reference
19、s are cited at the appropriate points in the text and the publications are listed on the inside back cover. Subsequent amendments to, or revisions of, any of these publications apply to this Part of BS 2646 only when incorporated in it by updating or revision. 1.2.2 Informative references This Part
20、of BS 2646 refers to other publications that provide information or guidance. Editions of these publications current at the time of issue of this standard are listed on the inside back cover, but reference should be made to the latest edition. 1.3 Definitions For the purposes of this Part of BS 2646
21、, the definitions given in BS 2646-1:1993 apply. 1.4 Test instruments and gauges 1.4.1 General Test instruments shall be used to check the accuracy of the autoclave instruments to the requirements of BS 2646-1:1993. They shall also be used to indicate or record pressure and temperatures at specified
22、 locations within the chamber during performance tests. Test gauges shall be used to check the accuracy of autoclave pressure and temperature gauges to the requirements of BS 1780:1985 and BS 5235:1975 respectively. 1.4.2 Calibration and verification of test instruments and gauges 1.4.2.1 Calibratio
23、n of test instruments shall be carried out as follows. a) A temperature reference standard shall be used (see 1.4.2.3). b) Test instruments shall be calibrated in accordance with the manufacturers instructions. 1.4.2.2 Test instruments with sensors connected shall be verified on-site using an indepe
24、ndent reference standard (see 1.4.2.3). NOTETest instruments should not be subjected to rapid variations in ambient temperature. 1.4.2.3 The temperature reference standard shall: a) incorporate a reference standard thermometer traceable to a national primary standard 3) . The thermometer shall inclu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS264651993AUTOCLAVESFORSTERILIZATIONINLABORATORIESMETHODSOFTESTFORFUNCTIONANDPERFORMANCE 实验室 高压 灭菌 功能

链接地址:http://www.mydoc123.com/p-543193.html