BS 2562-1979 Specification for cable boxes for transformers and reactors《变压器与电抗器用电缆箱规范》.pdf
《BS 2562-1979 Specification for cable boxes for transformers and reactors《变压器与电抗器用电缆箱规范》.pdf》由会员分享,可在线阅读,更多相关《BS 2562-1979 Specification for cable boxes for transformers and reactors《变压器与电抗器用电缆箱规范》.pdf(70页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS2562:1979 Specification for Cable boxes for transformers andreactors UDC 621.315.687:621.314.2+621.318.43BS2562:1979 This British Standard, having been prepared under the directionof the Power ElectricalEngineering StandardsCommittee, waspublished under the authorityof the Executi
2、ve Boardand comes intoeffecton 31December1979 BSI 06-1999 First published in Parts, as BS2562-1:1955 BS2562-2:1959 First published as one standard December1979 The following BSI references relate to the work on this standard: Committee reference PEL/113 Draft for comment74/28844DC ISBN 0 580 10831 7
3、 Cooperating organizations The Power Electrical Engineering Standards Committee, under whose direction this British Standard was prepared, consists of representatives from the following Government departments and scientific and industrial organizations: Associated Offices Technical Committee Associa
4、tion of Short Circuit Testing Authorities British Electrical and Allied Manufacturers Association (BEAMA) British Railways Board* British Steel Corporation Department of Energy (Electricity) Electrical Contractors Association Electrical Contractors Association of Scotland Electrical Research Associa
5、tion Electricity Supply industry in England and Wales* Engineering Equipment Users Association* Institute of Purchasing and Supply Institution of Electrical Engineers Ministry of Defence National Coal Board* National Economic Development Office The organizations marked with an asterisk in the above
6、list, together with the following, were directly represented on the committee entrusted with the preparation of this British Standard: Association of Consulting Engineers Bureau of Engineer Surveyors Electric Cable Makers Confederation London Transport Executive Transmission and Distribution Associa
7、tion (BEAMA) Amendments issued since publication Amd. No. Date of issue CommentsBS2562:1979 BSI 06-1999 i Contents Page Cooperating organizations Inside front cover Foreword iv Section 1. General 1 Scope 1 2 References 1 3 Definitions 1 Section 2. Performance and design requirements for cable boxes
8、4 Electrical requirements and clearances 2 5 Electromagnetic considerations 3 6 Provision for receiving cables 3 7 General design requirements 3 Section 3. Tests for cable boxes 8 Type tests 4 9 Routine tests 5 Section 4. Requirements for a range of single-pole, three-pole and four-pole cableboxes 1
9、0 Basis of range of boxes specified 5 11 Bushings 5 12 Cast resin bushing assemblies 6 13 Shell dimensions 7 Appendix A Information to be given with enquiry and order 50 Appendix B Wiping glands for metallic sheathed cables 50 Figure 1 Standard porcelains 20 Figure 2 Bushing clamps 21 Figure 3 Assem
10、bly of250A and400A porcelain bushingsforuseupto12kVrated voltage 22 Figure 4 Assembly of250A and400A epoxide resin bushingsforuseupto12kV rated voltage 23 Figure 5 Assembly of800A porcelain bushingforuseupto12kVratedvoltage 24 Figure 6 Assembly of800A epoxide resin bushingforuseupto12kVratedvoltage
11、25 Figure 7 Assembly of1 600A porcelain bushingforuseupto12kVratedvoltage 26 Figure 8 Assembly of1600A epoxide resin bushing for use up to12kV rated voltage 27 Figure 9 Assembly of2 500A porcelain bushing for use up to12kV rated voltage 28 Figure 10 Assembly of2 500A epoxide resin bushing for use up
12、 to12kV rated voltage 29 Figure 11 Assembly of250A porcelain bushing for use up to24kV rated voltage 30 Figure 12 Assembly of525A and800A porcelain bushings for use up to24kV rated voltage 31 Figure 13 Assembly of250A porcelain bushing for use up to36kV rated voltage 32 Figure 14 Assembly of800A por
13、celain bushing for use up to36kV rated voltage 33 Figure 15 Assembly of800A condenser bushing for use up to36kV rated voltage 34BS2562:1979 ii BSI 06-1999 Page Figure 16 800A and1 400A cast resin bushing assemblies for use up to1.1kV rated voltage 35 Figure 17 Bushing mounting plates for single-pole
14、 boxes (for use up to3.6kV rated voltage) 36 Figure 18 Bushing mounting plates for three-pole boxes (for use up to3.6kV rated voltage) 37 Figure 19 Bushing mounting plates for four-pole boxes (for use up to3.6kV rated voltage) 38 Figure 20 Copper based alloy bushing end caps, designations A, B, C an
15、d D 39 Figure 21 Copper based alloy cable connectors and ferrules 40 Figure 22 Copper based alloy bushing end caps, designations1to7 41 Figure 23 Facings for single-pole boxes 42 Figure 24 Facings for three-pole boxes 43 Figure 25 Facings for four-pole boxes 44 Figure 26 Typical arrangement of gland
16、 plate mounting for compound filled boxes 45 Figure 27 Assembly of filling orifice 46 Figure 28 Shell dimensions for filled boxes (for use up to12kV rated voltage) 47 Figure 29 Shell dimensions for filled boxes (for use at24kV and36kV rated voltage) 48 Figure 30 Shell dimensions for unfilled boxes w
17、ith cast resin bushingassemblies in accordance with Figure 16 for use up to1.1kVratedvoltage and individual bushing assemblies for use upto3.6kVrated voltage 49 Figure 31 Gland size X 52 Figure 32 Gland size Y 53 Figure 33 Gland size Z 54 Figure 34 Typical arrangement of uninsulated gland assembly t
18、ypes A and B 55 Figure 35 Moulded insulator for gland assembly types C2 and D2 56 Figure 36 Typical arrangement of insulated gland assembly(utilizingmoulded insulator) types C2 and D2 57 Figure 37 Insulation for gland assembly types C1, D1, E1 and F1 58 Figure 38 Typical arrangement of insulated gla
19、nd assembly (utilizinginsulating plate and bushes) types C1 and D1 59 Figure 39 Island layers for gland assembly types E1 and F1 60 Figure 40 Typical arrangement of insulated gland assembly with islandlayer(utilizing insulating plates and bushes) types E1 and F1 61 Figure 41 Armour clamps 62 Table 1
20、 Clearances 3 Table 2 Terminal stems and nuts 5 Table 3 Cable box ratings, shell dimensions and general particulars for filledboxes with porcelain bushings; single-pole boxes1.1kV to12kV 8 Table 4 Cable box ratings, shell dimensions and general particulars for filledboxes with porcelain bushings; th
21、ree-pole boxes1.1kV to12kV 9 Table 5 Cable box ratings, shell dimensions and general particulars for filledboxes with porcelain bushings; four-pole boxes1.1kV to12kV 11BS2562:1979 BSI 06-1999 iii Page Table 6 Cable box ratings, shell dimensions and general particularsforfilledboxes with porcelain bu
22、shings; single-pole and three-pole boxes24kV and36kV 13 Table 7 Cable box ratings, shell dimensions and general particulars for filledboxes with cast resin bushing assemblies; four-pole boxes1.1kV 14 Table 8 Cable box ratings, shell dimensions and general particulars forunfilled boxes with porcelain
23、 bushings; single-pole boxes1.1kV 14 Table 9 Cable box ratings, shell dimensions and general particulars for unfilled boxes with porcelain bushings; three-pole boxes1.1kV and3.6kV 15 Table 10 Cable box ratings, shell dimensions and general particulars for unfilled boxes with porcelain bushings; four
24、-pole boxes1.1kV and3.6kV 17 Table 11 Cable box ratings, shell dimensions and general particulars for unfilled boxes with cast resin bushing assemblies; four-pole boxes1.1kV 19 Table 12 Gland sizes 50 Publications referred to Inside back coverBS2562:1979 iv BSI 06-1999 Foreword This revision of BS25
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS25621979SPECIFICATIONFORCABLEBOXESFORTRANSFORMERSANDREACTORS 变压器 电抗 器用 电缆 规范 PDF

链接地址:http://www.mydoc123.com/p-543169.html