《BS 1902-3 16-1990 Methods of testing refractory materials - General and textural properties - Determination of pore size distribution (method 1902-316)《耐火材料试验方法 总则和结构特性 气孔尺寸分布测定(19.pdf》由会员分享,可在线阅读,更多相关《BS 1902-3 16-1990 Methods of testing refractory materials - General and textural properties - Determination of pore size distribution (method 1902-316)《耐火材料试验方法 总则和结构特性 气孔尺寸分布测定(19.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS1902-3.16: 1990 Methods of testing Refractory materials Part 3: General and textural properties Section3.16 Determination of pore size distribution (method1902-316)BS1902-3.16:1990 This British Standard, having been prepared under the directionof the Refractory Products Standards
2、Policy Committee, was published underthe authority of the BoardofBSI and comes into effect on 30 November1990 BSI08-1999 The following BSI references relate to the work on this standard: Committee reference RPM/1 Draft for comment88/44009DC ISBN 0 580 18364 5 Committees responsible for this British
3、Standard The preparation of this British Standard was entrusted by the Refractory Products Standards Policy Committee (RPM/-) to Technical Committee RPM/1, upon which the following bodies were represented: British Ceramic Research Ltd. British Steel Industry Electricity Supply Industry in England an
4、d Wales Engineering Equipment and Materials Users Association Refractories Association of Great Britain Refractory Contractors Association Society of Glass Technology Amendments issued since publication Amd. No. Date CommentsBS1902-3.16:1990 BSI 08-1999 i Contents Page Committees responsible Inside
5、front cover Foreword ii 1 Scope 1 2 Designation 1 3 Definitions 1 4 Principle 1 5 Apparatus 2 6 Test samples 2 7 Procedure 3 8 Calculation of results 6 9 Test report 7 Figure 1 General arrangements of coarse and fine pore measuring devices illustrating two methods of detecting the mercury level in t
6、he capillary 4 Figure 2 Schematic arrangement of sample holder 5 Table 1 Examples of ways of presenting results 6 Table 2 Density of mercury 7 Publications referred to Inside back coverBS1902-3.16:1990 ii BSI 08-1999 Foreword This Section of BS1902-3 has been prepared under the direction of the Refr
7、actory Products Standards Policy Committee. The method is based on measurement of pore size distribution by mercury intrusion. As very high pressures are used in the determination and small volumes of mercury are measured, it is more convenient to use a commercially available apparatus than to const
8、ruct one to comply with this method. The manufacturers operating manuals give details of how their apparatus is to be used. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance
9、with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amen
10、dments incorporated. This will be indicated in the amendment table on the inside front cover.BS1902-3.16:1990 BSI 08-1999 1 NOTEThis Section is to be used in conjunction with BS1902-3.0 “Introduction” and BS1902-3.1 “Guidance on sampling”. Section3.0 shows the general arrangement of BS1902 and lists
11、 the Sections of Part3. 1 Scope This Section of BS1902-3 describes a method for the measurement of pore size distributions of solid and granular refractory material. The method can be used to measure pore diameters in the approximate range0.006m to600m. NOTE 1The assumed model in this method has all
12、 the pores parallel sided and of circular cross section; the results are reported as equivalent pore diameters. A model for pores of different cross section, e.g.elliptical, can be derived by making appropriate adjustments to the mathematics. NOTE 2This method is unsuitable for materials that: a) co
13、ntain volatile compounds which give off vapours when placed under vacuum; b) contain metals that amalgamate with mercury. NOTE 3The titles of the publications referred to in this standard are listed on the inside back cover. 2 Designation The method of determining pore size distribution described in
14、 this Section is referred to by the following designation. Method1902-316. 3 Definitions For the purposes of this Section of BS1902 the following definitions apply. 3.1 item the brick, or bag of granular raw material, which is to be tested 3.2 test sample the portion of sample on which pore size mea
15、surements are made, in the form of a cut piece of brick or of granular particles 3.3 equivalent pore diameter the diameter of a pore at a given pressure which represents the pores of irregular cross section impregnated by mercury at that pressure 3.4 ink bottle pores non-parallel sided pores in the
16、form of an ink bottle with a narrow neck and a wide body, measured as if the whole pore was of the same diameter as the neck 3.5 coarse pores pores with diameters greater than or equal to10m, whose equivalent diameters are measured with the coarse pore measuring device 3.6 fine pores pores with diam
17、eters less than10m whose equivalent diameters are measured with the fine pore measuring device 3.7 mercury filling device apparatus which is made so that only fine pores can be measured, employed to evacuate and fill the sample holder with mercury 3.8 coarse pore measuring device an apparatus for me
18、asuring the proportion of coarse pores present in a sample, combining the functions of mercury filler and pore measurer 3.9 fine pore measuring device an apparatus for measuring the proportion of fine pores present in a sample 3.10 apparent solid density the ratio of the mass of the material to its
19、apparent solid volume, which is the volume of the solid material plus the volume of the closed pores 4 Principle A test sample is placed in a vessel which is evacuated and filled with mercury. The pressure on the mercury is increased to force it into progressively finer pores and measurement of the
20、volume of mercury forced into the pores at different pressures enables the pore size distribution to be determined. The data obtained can also be used to calculate the apparent porosity, bulk density, and apparent solid density of the test sample (see8.4).BS 1902-3.16:1990 2 BSI 08-1999 5 Apparatus
21、NOTEThe general arrangements of coarse and fine pore measuring devices illustrating two methods of detecting the mercury level in the capillary are shown in Figure 1. 5.1 Sample holder, as shown in Figure 2, constructed in such a way that the base of the sample holder and the uniform capillary tube
22、forming the neck can be separated from each other, to allow the test sample to be inserted. The volume of the holder shall be sufficient to accommodate a test sample of not less than1cm 3 . The holder shall be designed so that electrical contact can be made with the mercury in the holder, either by
23、an appropriately designed removeable bottom, or by fusing an electrode through the well. 5.2 Mercury filling device, which may be separate from, or an integral part of the coarse pore measuring device(5.5). This filling device shall be capable of evacuating the sample holder to a pressure of2.67Pa(2
24、0mHg). After evacuation the device shall enable the evacuated sample holder to be filled with mercury by means of a system of valves. 5.3 Mercury, of triple distilled quality. WARNING. It is important that proper precautions for the protection of laboratory personnel are taken when mercury is used.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS19023161990METHODSOFTESTINGREFRACTORYMATERIALSGENERALANDTEXTURALPROPERTIESDETERMINATIONOFPORESIZEDISTRIBUTIONMETHOD1902316

链接地址:http://www.mydoc123.com/p-542991.html