BS 1428-B2-1960 Microchemical analysis - Apparatus for the determination of elements by other than combustion methods - Specification for ammonia distillation apparatus (Markham)《微.pdf
《BS 1428-B2-1960 Microchemical analysis - Apparatus for the determination of elements by other than combustion methods - Specification for ammonia distillation apparatus (Markham)《微.pdf》由会员分享,可在线阅读,更多相关《BS 1428-B2-1960 Microchemical analysis - Apparatus for the determination of elements by other than combustion methods - Specification for ammonia distillation apparatus (Markham)《微.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS1428-B2: 1960 Specification for Ammonia distillation apparatus (Markham) Microchemical apparatus Group B: apparatus for the determination of elements by other than combustion methodsBS1428-B2:1960 This BritishStandard, having been approved by the ScientificGlassware and RelatedLab
2、oratory ApparatusIndustry StandardsCommittee and endorsed by the Chairman oftheChemical Divisional Council, was published undertheauthority of the GeneralCouncil on 29February1960 BSI12-1999 First published December1953 First revision February1960 The following BSI references relate to the work on t
3、his standard: Committee references LBC/11 andLBC/11/1 Draft for comment CZ (LBC)5632 ISBN 0 580 34147 X Co-operating organizations The Scientific Glassware and Related Laboratory Apparatus Industry Standards Committee, under whose supervision this BritishStandard was prepared, consists of representa
4、tives from the following Government departments and scientific and industrial organizations: Admiralty* Air Ministry Association of British Chemical Manufacturers* Association of Scientific Workers Board of Trade British Association for the Advancement of Science British Chemical Ware Manufacturers
5、Association* British Laboratory Ware Association* British Lampblown Scientific Glassware Manufacturers Association* British Pharmacopoeia Commission British Scientific Instrument Research Association* Chemical Society* D.S.I.R.Laboratory of the Government Chemist* D.S.I.R.National Chemical Laborator
6、y* Glass Manufacturers Federation* Institute of Petroleum Ministry of Aviation* Ministry of Health National Physical Laboratory (D.S.I.R.)* Oil Companies Materials Association Pharmaceutical Society of Great Britain* Royal Institute of Chemistry* Science Masters Association Society for Analytical Ch
7、emistry* Society of Chemical Industry* Society of Glass Technology* Standardization of Tar Products Tests Committee The Government departments and scientific and industrial organizations marked with an asterisk in the above list, together with the following, were directly represented on the committe
8、e entrusted with the preparation of this standard: Association of Clinical Pathologists British Rubber Producers Research Association Medical Research Council Physiological Society War Office Individual Manufacturers Amendments issued since publication Amd. No. Date CommentsBS1428-B2:1960 BSI 12-199
9、9 i Contents Page Co-operating organizations Inside front cover Foreword ii 1 Scope 1 2 Material 1 3 Design and dimensions 1 4 Alternative apparatus with ground joint 1 Appendix A Notes on method of use 2 Appendix B 4 Figure 1 Markham ammonia distillation apparatus 3BS1428-B2:1960 ii BSI 12-1999 For
10、eword This standard makes reference to the following BritishStandards: BS1428-A2, Nitrogen combustion train (micro-Dumas). BS1428-B1, Nitrogen determination apparatus (micro-Kjeldahl). BS1848, Glass condensers. BS2761, Spherical ground glass joints. This standard, which was first published in1953, i
11、s one of a series of Parts of BS1428 “Microchemical Apparatus”, (see list in Appendix B). The only substantial changes in the present revision are that the design of the condenser is now that specified in BS1848 1)and that the alternative, jointed apparatus now employs only the spherical joint intro
12、duced by amendment in1956, the conical joint previously permitted having been deleted. PartB2 specifies an ammonia distillation apparatus of the type described by Markham 2) , which has been found especially useful for biochemical work. It has disadvantages if the quantity of distillant used exceeds
13、25ml, and in this case more satisfactory results may be obtained by the addition of a splash-head, of the type specified in BS1428- B1 3) , between the distillation vessel and the condenser. While only the apparatus is specified in this and other parts of BS1428, it must be made clear that satisfact
14、ory results will not be obtained without careful attention to the procedure in carrying out the determination, and that this requires both training and experience in microchemical work. Notes on the method of use of the apparatus are given for guidance in Appendix A, but these are not intended to be
15、 either mandatory or comprehensive. Apparatus for the micro-determination of nitrogen is specified also in BS1428-A2 4)and BS1428-B1 3) A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application.
16、 Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to4 and a back cover. This standard has been updated (see copyright date) and may have had amendments inc
17、orporated. This will be indicated in the amendment table on the inside front cover. 1) BS1848, “Glass condensers”. 2) R. MARKHAM, Biochem. J.,36,1942,790. 3) BS1428-B1, “Nitrogen determination apparatus (micro-Kjeldahl)”. 4) BS1428-A2, “Nitrogen combustion train (micro-Dumas)”.BS1428-B2:1960 BSI 12-
18、1999 1 1 Scope This BritishStandard specifies steam-jacketed distillation apparatus of the Markham type for the micro-determination of nitrogen by the Kjeldahl method. 2 Material The apparatus shall be constructed throughout of borosilicate glass, as free as possible from visible defects, and shall
19、be well annealed. 3 Design and dimensions The apparatus shall conform to the general design shown in Figure 1 and shall comply with the mandatory dimensions, which are underlined in the figure. Dimensions not underlined in the figure are recommended. The connection between the filling funnel and the
20、 main body, and also the glass tubing between the distillation vessel and the condenser, shall be robust. 4 Alternative apparatus with ground joint As an alternative to the one-piece apparatus illustrated in Figure 1, an interchangeable spherical ground glass joint, size18/9 BS, complying with BS276
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS1428B21960MICROCHEMICALANALYSISAPPARATUSFORTHEDETERMINATIONOFELEMENTSBYOTHERTHANCOMBUSTIONMETHODSSPECIFICATIONFORAMMONIADISTILLATIONAPPARATUSMARKHAM

链接地址:http://www.mydoc123.com/p-542747.html