BS 1365-1990 Specification for short-range short-stem thermometers《小量程短柄温度计规范》.pdf
《BS 1365-1990 Specification for short-range short-stem thermometers《小量程短柄温度计规范》.pdf》由会员分享,可在线阅读,更多相关《BS 1365-1990 Specification for short-range short-stem thermometers《小量程短柄温度计规范》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD CONFIRMED AUGUST 1997 BS 1365:1990 Specification for Short-range short-stem thermometersBS1365:1990 This British Standard, having been prepared under the directionof the Laboratory Apparatus Standards Policy Committee, was published underthe authority of the BoardofBSI and comes int
2、oeffecton 31May 1990 BSI 07-1999 First published February 1951 First revision June 1975 Second revision May 1990 The following BSI references relate to the work on this standard: Committee reference LBC/4 Draft for comment 89/56008 ISBN 0 580 18147 2 Committees responsible for this British Standard
3、The preparation of this British Standard was entrusted by the Laboratory Apparatus Standards Policy Committee (LBC/-) to Technical Committee LBC/4, upon which the following bodies were represented: British Laboratory Ware Association British Medical Association Department of Health Department of Tra
4、de and Industry (National Physical Laboratory) Institute of Petroleum Medical Sterile Products Association Scientific Glassware Association Amendments issued since publication Amd. No. Date of issue CommentsBS1365:1990 BSI 07-1999 i Contents Page Committees responsible Inside front cover Foreword ii
5、 1 Scope 1 2 Type and designation 1 3 Temperature scale 1 4 Bulb 1 5 Stem 1 6 Annealing 1 7 Stabilization 1 8 Graduation and figuring 1 9 Immersion line 1 10 Expansion volume 4 11 Finish 4 12 Enlargements of the bore 4 13 Dimensions of scale ranges 4 14 Marking 4 Appendix A Emergent liquid column te
6、mperatures for partial immersion thermometers 5 Appendix B Testing of thermometers 5 Appendix C Thermometric glasses approved by the National Physical Laboratory 5 Appendix D Stabilization test 6 Figure 1 Examples of scale lines and figuring 2 Table 1 Graduation, figuring and general dimensions 2 Ta
7、ble 2 Scale ranges and tolerances 3 Table 3 Recommended limits of uncertainty of test 6 Table 4 Identification stripe(s) or approved abbreviations and normal maximum working temperature of all glasses that have been approved for the manufacture of thermometer bulbs 7 Publication referred to Inside b
8、ack coverBS1365:1990 ii BSI 07-1999 Foreword This British Standard has been prepared under the direction of the Laboratory Apparatus Standards Policy Committee, and supersedes BS 1365:1975 which is withdrawn. This British Standard was first published in 1951 to meet the requirements for thermometers
9、 of the Anschutz and similar types, i.e. with comparatively short stems and graduated to cover scale spans of approximately 60 C (series A) and10C (series B). The first revision in 1975 introduced a more open scale for both series A and B thermometers to facilitate reading without loss of accuracy a
10、nd a greater permissible error for series A thermometers. An appendix on emergent liquid column temperature correction (Appendix A) was added for use with thermometers under partial immersion conditions. This revision introduces changes to bring the standard up to date and in particular to modify th
11、e information on available glasses and arrangements for calibration and testing but retains the other requirements of the 1975 edition. Series A refers to a series of overlapping short-range thermometers which collectively cover a range of 10C to +360C. Series B refers to a series of overlapping sho
12、rt-stem thermometers which collectively cover a range of 10C to +220C. Series B thermometers are recommended for use in determining melting points and setting points. Information on the testing of short-range short-stem thermometers is given in Appendix B. Product certification. Users of this Britis
13、h Standard are advised to consider the desirability of third party certification of product conformity with this British Standard based on testing and continuing surveillance, which may be coupled with assessment of a suppliers quality systems against the appropriate Part ofBS5750. Enquiries as to t
14、he availability of third party certification schemes will be forwarded by BSI to the Association of Certification Bodies. If a third party certification scheme does not already exist, users should consider approaching an appropriate body from the list of Association members. A British Standard does
15、not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside
16、 front cover, pages i and ii, pages1 to 8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS1365:1990 BSI 07-1999 1 1 Scope This British Stand
17、ard specifies requirements for two series, A and B, of mercury-in-glass thermometers. In each series, thermometers calibrated for total immersion, i.e. immersion to the reading (designated A1 or B1) and thermometers calibrated for partial immersion (designated A2 or B2) are included for each tempera
18、ture range. Series A1 comprises seven total immersion thermometers, each with a scale span of approximately60Celsius degrees, covering the range 10C to +360C. Series A2 covers the same range for an immersion of80mm. Series B1 comprises24total immersion thermometers, each with a scale span of approxi
19、mately10Celsius degrees, covering the range 10C to +220C. Series B2 covers the same range for an immersion of70mm. NOTEThe title of the publication referred to in this standard is listed on the inside back cover. 2 Type and designation Thermometers shall be of the mercury-in-glass solid-stem type an
20、d shall be filled with inert gas at an appropriate pressure. Each thermometer shall be designated by a designation consisting of the code letters SA or SB (for short-range series A or B respectively), followed by a nominal maximum working temperature and an indication of the immersion depth at which
21、 the thermometer is to be used, e.g. SA 55C/Total, SB IC/70. 3 Temperature scale Thermometers shall be graduated in accordance with the Celsius scale as defined in the current definition of the International Practical Temperature Scale adopted by the General Conference of Weights and Measures (CGPM)
22、. 4 Bulb The bulb shall be cylindrical and in alignment with the stem. Its external diameter shall not exceed that of the stem. It shall be of a thermometric glass approved by the National Physical Laboratory and suitable for the range of temperature covered (seeAppendix C). 5 Stem For thermometers
23、in which the upper level of the scale is above300C, the same thermometric glass shall be used for both the bulb and the stem. NOTEFor thermometers in which the upper level of the scale is 300C or less, it is recommended that the stem should be made of the same thermometric glass as the bulb but it i
24、s also permissible for the stem to be made of lead glass or other suitable glass with an enamel back. 6 Annealing Strain in the glass shall be reduced to a level sufficient to minimize the possibility of fracture due to mechanical or thermal shock. 7 Stabilization The thermometer shall be stabilized
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS13651990SPECIFICATIONFORSHORTRANGESHORTSTEMTHERMOMETERS 量程 温度计 规范 PDF

链接地址:http://www.mydoc123.com/p-542730.html