BS 1363-5-2016 13 A plugs socket-outlets adaptors and connection units Part 5 Specification for fused conversion plugs《13A插头、电源插座、适配器和连接装置 第5部分 装有保险丝的转换插头用规范》.pdf
《BS 1363-5-2016 13 A plugs socket-outlets adaptors and connection units Part 5 Specification for fused conversion plugs《13A插头、电源插座、适配器和连接装置 第5部分 装有保险丝的转换插头用规范》.pdf》由会员分享,可在线阅读,更多相关《BS 1363-5-2016 13 A plugs socket-outlets adaptors and connection units Part 5 Specification for fused conversion plugs《13A插头、电源插座、适配器和连接装置 第5部分 装有保险丝的转换插头用规范》.pdf(80页珍藏版)》请在麦多课文档分享上搜索。
1、BS 1363-5:201613 A plugs, socket-outlets,adaptors and connectionunitsPart 5: Specification for fusedconversion plugsBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Publishing and copyright informationThe BSI copyright notice displayed in this document indicates when
2、the documentwas last issued. The British Standards Institution 2016Published by BSI Standards Limited 2016ISBN 978 0 580 85813 0ICS 29.120.30The following BSI references relate to the work on this document:Committee reference PEL/23Draft for comment 15/30297240 DCPublication historyFirst published A
3、ugust 2008Second (present) edition, August 2016Amendments issued since publicationDate Text affectedBS 1363-5:2016 BRITISH STANDARDContentsForeword iii1 Scope 12 Normative references 13 Terms and definitions 24 Classification 55 General requirements 56 Testing regime 67 Marking and labelling 88 Clea
4、rances, creepage distances, and solid insulation 109 Accessibility of live parts 1410 Provision for earthing 1511 Contacts in conversion plugs 1612 Construction of conversion plugs 1613 (Not used) 2614 Resistance to ageing and to humidity 2615 Insulation resistance and electric strength 2716 Tempera
5、ture rise 2817 (Not used) 3018 (Not used) 3019 Connection of the non-BS 1363 type plug and non-BS 1363 type plugretention in conversion plugs 3020 Mechanical strength 3321 Screws, current-carrying parts and connections 3422 Resistance to heat 3623 Resistance to abnormal heat and fire 3724 Resistance
6、 to excessive residual stresses and to rusting 38AnnexesAnnex A (normative) The construction and calibration of a calibrated link 63Annex B (normative) Measurement of clearances and creepage distances 64Annex C (normative) Determination of the comparative tracking index (CTI) andproof tracking index
7、 (PTI) 68Annex D (normative) Relationship between rated impulse withstand voltage,rated voltage and Overvoltage Category 68Annex E (normative) Pollution degree 69Annex F (normative) Impulse voltage test 69Bibliography 71List of figuresFigure1Testpin(see Clause 12) 39Figure 2a Apparatus for mechanica
8、l strength test on resilient covers (see Clause9) 40Figure 2b Hardwood block for Figure 2a 41Figure 4a Dimensions and disposition of pins (see Clause 12) 42Figure 4b Concave shrinkage allowance for ISODs 44Figure 5 Gauge for plug pins (see Clause 12, Clause 20 and Clause 22) 45Figure 6 Apparatus for
9、 testing plug cover fixing screws (see Clause 12) 46Figure 7 Mounting plate (see Clause 12) 47Figure 8 Plug pin deflection test apparatus for resilient plugs(see Clause 12) 48Figure 9 Apparatus for abrasion test on insulating sleeves of plug pins (seeClause 12) 50Figure 10 Apparatus for pressure tes
10、t at high temperature (see Clause 12) 51Figure 11 GO gauge for socket-outlet (see Clause 13) 52Figure 17a Test apparatus for temperature rise test (see Clause 16) 53Figure 17b Dummy front plate for temperature rise (see Clause 16) 54Figure 18 Apparatus for flexing test (see Clause 19) 55BRITISH STAN
11、DARD BS 1363-5:2016 The British Standards Institution 2016 iFigure 19 Solid link for test on fuse clips (see Clause 20) 56Figure 20 Tumbling barrel (see Clause 20) 56Figure 23 Apparatus for pressure test (see Clause 22) 57Figure 24 Apparatus for ball pressure test (see Clause 22) 58Figure 28 Calibra
12、ted link (see A.1) 59Figure 29 Calibration jig for calibrated link (see A.2) 60Figure 32a Apparatus for tests on conversion plug pins: A plug pin under test(see Clause 12) 61Figure 32b Apparatus for tests on conversion plug pins: Details of anvils(see Clause 12) 62Figure 33 Apparatus for torsion tes
13、t on pins (see Clause 12) 62Example 1 65Example 2 65Example 3 65Example 4 65Example 5 66Example 6 66Example 7 66Example 8 66Example 9 67Example 10 67Example 11 68List of tablesTable 1 Schedule of tests 7Table 2 Rated current and maximum fuse rating in normal use, and load forflexing and cable grip t
14、ests related to size of flexible cable 9Table 3 Minimum clearances for basic insulation 11Table 4 Minimum creepage distances (mm) for basic insulation 12Table 5 Withstand voltages for insulation types 14Table 6 Permitted temperature rises 29Table7Torque values for screws and nuts 31Table 8 Plug disp
15、lacement test loads 32Table 9 Application of glow-wire test 38Table B.1 Minimum values of width X64Table D.1 Rated impulse withstand voltage for conversion plugs energizeddirectly from the low voltage mains 68Table F.1 Test voltages for verifying clearances at sea level 70Summary of pagesThis docume
16、nt comprises a front cover, an inside front cover, pages i to iv, pages1 to 72, an inside back cover and a back cover.BRITISH STANDARDBS 1363-5:2016ii The British Standards Institution 2016ForewordPublishing informationThis part of BS 1363 is published by BSI Standards Limited, under licence fromThe
17、 British Standards Institution, and came into effect on 31 August 2016. It wasprepared by Technical Committee PEL/23, Electrical accessories. A list oforganizations represented on this committee can be obtained on request to itssecretary.SupersessionThis part of BS 1363 supersedes BS 1363-5:2008, wh
18、ich remains current and willbe withdrawn on 31 August 2019.Information about this documentBS 1363 comprises five parts covering the following: Part 1: Specification for rewirable and non-rewirable 13 A fused plugs; Part 2: Specification for 13 A switched and unswitched socket-outlets; Part 3: Specif
19、ication for adaptors; Part 4: Specification for 13 A fused connection units switched andunswitched; Part 5: Specification for fused conversion plugs.NOTE In order to prevent confusion with BS 1363:1984, the figure andclause numbers have been retained.This new edition of BS 1363-5 incorporates techni
20、cal changes only. It does notrepresent a full review or revision of the standard, which will be undertaken indue course.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Itsrequirements are expressed in sentences in which the principal auxiliary ve
21、rb is“shall”.Commentary, explanation and general informative material is presented insmaller italic type, and does not constitute a normative element.Requirements in this standard are drafted in accordance with Rules for thestructure and drafting of UK standards, subclause J.1.1, which states,Requir
22、ements should be expressed using wording such as: When tested asdescribed in Annex A, the product shall . This means that only those productsthat are capable of passing the specified test will be deemed to conform to thisstandard.Contractual and legal considerationsThis publication does not purport
23、to include all the necessary provisions of acontract. Users are responsible for its correct application.Conformity with a British Standard cannot confer immunity from legalobligations.Particular attention is drawn to the following specific regulations:The Plugs and Sockets etc. (Safety) Regulations
24、1994. SI No. 1768.BRITISH STANDARD BS 1363-5:2016 The British Standards Institution 2016 iiiBRITISH STANDARDBS 1363-5:2016This page deliberately left blankiv The British Standards Institution 20161 ScopeThis part of BS 1363 specifies requirements, with particular reference to safety innormal use, fo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS13635201613APLUGSSOCKETOUTLETSADAPTORSANDCONNECTIONUNITSPART5SPECIFICATIONFORFUSEDCONVERSIONPLUGS13A

链接地址:http://www.mydoc123.com/p-542729.html