BS 1016-1-1973 Methods for analysis and testing of coal and coke - Total moisture of coal《煤和焦炭的分析与试验方法 第1部分 煤的总含水量》.pdf
《BS 1016-1-1973 Methods for analysis and testing of coal and coke - Total moisture of coal《煤和焦炭的分析与试验方法 第1部分 煤的总含水量》.pdf》由会员分享,可在线阅读,更多相关《BS 1016-1-1973 Methods for analysis and testing of coal and coke - Total moisture of coal《煤和焦炭的分析与试验方法 第1部分 煤的总含水量》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD CONFIRMED SEPTEMBER 1989 BS 1016-1: 1973 Methods for The analysis and testing of coal and coke Part 1: Total moisture of coal UDC 662.66 + 662.74:543 + 662.66:543.712.2BS1016-1:1973 This British Standard, having been approved by the Solid FuelIndustry Standards Committee, was publis
2、hed underthe authority of the Executive Board on 15October1973 BSI 07-1999 First published, March 1942 First revision, February 1957 Second revision, October 1973 The following BSI references relate to the work on this standard: Committee reference SFE/45 and SFE/45/8 Draft for comment 72/40657 ISBN
3、 0 580 076873 Co-operating organizations The Solid Fuel Industry Standards Committee, under whose supervision this British Standard was prepared, consists of representatives from the following Government departments and scientific and industrial organizations: A British Standard does not purport to
4、include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, p
5、ages i and ii, pages 1 to 6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Association of Consulting Engineers Electricity Council, the Cent
6、ral Electricity British Cast Iron Research Association Generating Board and Area Boards in British Coke Research Association* England and Wales* British Ironfounders Association Greater London Council British Mechanical Engineering Heating and Ventilating Contractors Confederation Association Britis
7、h Steel Industry* Institute of British Foundrymen* Chamber of Coal Traders Institute of Fuel* Chemical Industries Association* Institution of Heating and Ventilating Coal Utilisation Council Engineers Coke Oven Managers Association* Institution of Mechanical Engineers* Combustion Engineering Associa
8、tion* Low Temperature Coal Distillers Association Council of Ironfoundry Associations of Great Britain Ltd. Department of the Environment National Coal Board* Department of Trade and Industry Society of British Gas Industries Domestic Solid Fuel Appliances Approval Water-tube Boilermakers Associatio
9、n* Scheme Womens Advisory Council on Solid Fuel The scientific and industrial organizations marked with an asterisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of this British Standard: British Coal Exporters Federation Sc
10、ientific Instrument Manufacturers British Gas Corporation Association of Great Britain Cement Makers Federation Society of Chemical Industry Institute of Trading Standards Solid Smokeless Fuels Federation Institution of Electrical Engineers South Wales Institute of Engineers London Coal Exporters As
11、sociation Independent experts Amendments issued since publication Amd. No. Date of issue CommentsBS1016-1:1973 BSI 07-1999 i Contents Page Co-operating organizations Inside front cover 1 Scope 1 2 Definitions 1 3 Coal sample 1 4 Moisture in the 13 mm coal sample 1 5 Moisture in the 3 mm coal sample
12、2 6 Calculation and reporting 4 7 Precision of the determination 4 8 Notes 4 Figure 1 Suitable nitrogen oven 5 Publications referred to Inside back coverii blankBS1016-1:1973 BSI 07-1999 1 1 Scope This British Standard describes alternative methods of determining the total moisture on samples of coa
13、l taken and prepared by the procedures given in BS1017-1. NOTEThe titles of the British Standards referred to in this standard are listed on the inside back cover. 2 Definitions For purposes of this British Standard, the following definitions apply: 2.1 total moisture the moisture in the coal as sam
14、pled 2.2 free moisture the moisture that is lost by the coal sample in attaining approximate equilibrium with the air to which it is exposed 2.3 moisture in air-dried coal the moisture in the coal sample after it has attained approximate equilibrium with the air to which it is exposed 2.4 high rank
15、coal a coal containing (arbitrarily) less than4% of moisture (in air-dried coal) and more than84% of carbon (dry, ash free basis) 2.5 low rank coal any coal other than a high rank coal. If the rank of the coal is not known it is treated as a low rank coal 2.6 repeatability the maximum acceptable dif
16、ference between single determinations carried out in one laboratory on two separate moisture samples taken simultaneously in accordance with the principles laid down in BS1017 1) 2.7 reproducibility the maximum acceptable difference between single determinations carried out in different laboratories
17、 on two separate moisture samples taken simultaneously in accordance with the principles laid down in BS1017 1) 3 Coal sample The sample for the determination of total moisture shall have been taken and prepared according to BS1017-1. It will be received in the laboratory in a sealed, air-tight cont
18、ainer and will consist either of1kg of coal having a maximum particle size of13mm or of not less than300g of air-dried coal having a maximum particle size of3mm. All samples, other than a1kg sample prepared from a coal having an initial top size of less than13mm or from a visibly dry high rank coal
19、of any top size, will have been air-dried before receipt and details of the loss in mass on air-drying, i.e.the free moisture, will be recorded on the label of the sample container (but see final paragraph of Foreword). 4 Moisture in the 13 mm coal sample 4.1 Distillation with toluene 4.1.1 Principl
20、e. This method is suitable for all coals. The whole of the1kg sample of coal is heated with toluene under reflux conditions. The toluene distils into a graduated receiver, carrying with it the water from the coal. The water then separates to form the lower layer. The excess toluene overflows from th
21、e receiver and returns to the flask. The moisture in the coal is calculated from the masses of the sample taken and of the water collected. 4.1.2 Special reagent. The following reagent is required: Toluene. Boiling point110 C, dry 2) . 4.1.3 Special apparatus. The following apparatus is required: De
22、an and Stark apparatus complying with BS756 and comprising: 1) a copper flask, capacity two litres. 2) a receiver, capacity100ml. 3) a condenser and spray tube, as specified in BS756. 4) heating apparatus: the flask may be heated directly by gas or electricity, or by immersion in a heated oil bath.
23、The receiver and condenser shall be cleaned before each determination by treating them with a suspension of potassium dichromate in sulphuric acid, or other suitable cleansing agent. 1) It should be noted that this definition differs from those in Parts 3 to 16 of BS 1016. 2) The residual toluene in
24、 the flask after a determination may be filtered and dried for re-use.BS1016-1:1973 2 BSI 07-1999 4.1.4 Procedure. Weigh the sample and container (seeNote1) as received to the nearest gram. Transfer the coal as completely as possible to the flask, carefully clean all traces of the sample from the so
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS101611973METHODSFORANALYSISANDTESTINGOFCOALANDCOKETOTALMOISTUREOFCOAL 焦炭 分析 试验 方法 部分 含水量 PDF

链接地址:http://www.mydoc123.com/p-542566.html