《ATIS 0600015 03-2013 Energy Efficiency for Telecommunication Equipment Methodology for Measurement and Reporting for Router and Ethernet Switch Products.pdf》由会员分享,可在线阅读,更多相关《ATIS 0600015 03-2013 Energy Efficiency for Telecommunication Equipment Methodology for Measurement and Reporting for Router and Ethernet Switch Products.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、 AMERICAN NATIONAL STANDARD FOR TELECOMMUNICATIONS ATIS-0600015.03.2013 ENERGY EFFICIENCY FOR TELECOMMUNICATION EQUIPMENT: METHODOLOGY FOR MEASUREMENT AND REPORTING FOR ROUTER AND ETHERNET SWITCH PRODUCTS As a leading technology and solutions development organization, ATIS brings together the top gl
2、obal ICT companies to advance the industrys most-pressing business priorities. Through ATIS committees and forums, nearly 200 companies address cloud services, device solutions, emergency services, M2M communications, cyber security, ehealth, network evolution, quality of service, billing support, o
3、perations, and more. These priorities follow a fast-track development lifecycle from design and innovation through solutions that include standards, specifications, requirements, business use cases, software toolkits, and interoperability testing. ATIS is accredited by the American National Standard
4、s Institute (ANSI). ATIS is the North American Organizational Partner for the 3rd Generation Partnership Project (3GPP), a founding Partner of oneM2M, a member and major U.S. contributor to the International Telecommunication Union (ITU) Radio and Telecommunications sectors, and a member of the Inte
5、r-American Telecommunication Commission (CITEL). For more information, visit . AMERICAN NATIONAL STANDARD Approval of an American National Standard requires review by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Cons
6、ensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and o
7、bjections be considered, and that a concerted effort be made towards their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or
8、using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an inte
9、rpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised o
10、r withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American
11、 National Standards Institute. Notice of Disclaimer 10; 100 a=0.1; b=0.8; c=0.1 (IPv4) Edge Router 3-6% 0; 10; 100 a=0.1; b=0.8; c=0.1 IPv4/6/MPLS Core Router 20-30% 0; 30; 100 a=0.1; b=0.8; c=0.1 IPv4/6/MPLS ATIS-0600015.03.2013 5 Table 2: Class definitions, TEER calculation parameters and load pro
12、files for Ethernet Switching Products Class Representative utilization % of utilization for energy measurements, u1, u2, u3 Weight multipliers a, b, c Traffic Profile Simple IMIX, Unicast Access 1-3% 0; 10; 100 a=0.1; b=0.8; c=0.1 Ethernet High Speed Access 5-8% 0; 10; 100 a=0.1; b=0.8; c=0.1 Ethern
13、et Distribution/Aggregation 10-15% 0;10;100 a=0.1; b=0.8; c=0.1 Ethernet Core 15-20% 0; 30; 100 a=0.1; b=0.8; c=0.1 Ethernet Data Center 12-18% 0; 30; 100 a=0.1; b=0.8; c=0.1 Ethernet 5.3 TEER Metric Definition (modular) TEER for modular packet-based network systems can also be estimated as throughp
14、ut measured for components/modules (Ti) divided by the sum of weighted components/modules power (energy consumption) (Pwi): niwiwbaseniiPPTTEER11Where: Ti= Individual Module Throughput Pwi= Individual Module Weighted Power Pwbase= Weighted Power of a Base System Excluding Modules Modular weighted po
15、wer Pwiand Pwbaseare calculated with the following formulas: 3*2*1*ucubua PPPPwi 3_*2_*1_*ubasecubasebubasea PPPPwbase Where: Pwi= Weighted Module Power Pwbase= Weighted Power of a Base System Excluding Modules (a, b, c) = Weighting for power at each utilization level, where a + b + c=1.0 (Pu1, Pu2,
16、 Pu3) = Module power at system utilization level (Pbase_u1, Pbase_u2, Pbase_u3) = Base power at system utilization level ATIS-0600015.03.2013 6 NOTE: Modular energy consumption and throughput are vendor approximations. When a modular TEER is provided, a representative-configuration TEER shall also b
17、e provided for comparison purposes. 5.4 TEER Evaluation To compare EE of products, they shall belong to the same product class. Recommended product classes are listed in Annex A. The class description covers the expected applications for EUTs deployed at certain points in the network. If the system
18、can be deployed in multiple roles, multiple TEER ratings can be provided. Examples of listing: 1. Medium Core Router, TEER=42 (representative HW/SW configuration follows). 2. Small Edge Router, estimated TEER = 50 (modular configuration based on component/module ratings). See Annex A for Classificat
19、ion Tables. Due to a wide variety of features and functions available on the EUT, it is very essential to report all features and functions active in the test configuration as described in Tables A.1 and A.2. 6 Test Procedure 6.1 General Measurement Condition The general requirements for measuring e
20、nergy efficiency are defined in ATIS-0600015.2009. The following are the general conditions for measurements within this standard: The equipment is to be powered and placed into the relevant operating mode. Allow the equipment to stabilize in this mode for 15 minutes. Measure the power for a period
21、of 15 minutes. If the power varies over the 15 minute measurement time interval, an average of the measurement will be calculated. 6.2 Equipment Configuration All testing shall be performed on a fully-loaded chassis, as defined by the referenced application. If there are customer specific applicatio
22、ns defining redundancy requirements, they should be clearly documented in the report. All ports shall be in an active state and passing or ready to pass traffic. System software (SW) shall be properly configured prior to the test and all the necessary HW components installed. HW and SW shall be repr
23、esentative of a production unit. There is no EUT configuration change allowed any time beyond preparation phase. This includes (but not limited to) external configuration commands, scripts executing configuration commands on EUT during testing, etc. 6.3 TEER Measurements Modular Method If the vendor
24、 chooses to provide the “modular” TEER estimates, it may be required to build more than one setup if the total number of modules exceeds the number of available slots in a chassis (or if some modules cannot be used together). In this case, the “base” system configuration is defined as a common syste
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ATIS0600015032013ENERGYEFFICIENCYFORTELECOMMUNICATIONEQUIPMENTMETHODOLOGYFORMEASUREMENTANDREPORTINGFORROUTERANDETHERNETSWITCHPRODUCTSPDF

链接地址:http://www.mydoc123.com/p-541230.html