ASTM F876-2006 Standard Specification for Crosslinked Polyethylene (PEX) Tubing《交联聚乙烯(PEX)管的标准规范》.pdf
《ASTM F876-2006 Standard Specification for Crosslinked Polyethylene (PEX) Tubing《交联聚乙烯(PEX)管的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F876-2006 Standard Specification for Crosslinked Polyethylene (PEX) Tubing《交联聚乙烯(PEX)管的标准规范》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 876 06An American National StandardStandard Specification forCrosslinked Polyethylene (PEX) Tubing1This standard is issued under the fixed designation F 876; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers crosslinked polyethylene(PEX) tubing that is outside diameter controlled, made instandard
3、 thermoplastic tubing dimension ratios, and pressurerated for water at three temperatures (see Appendix X1).Included are requirements and test methods for material,workmanship, dimensions, sustained pressure, burst pressure,environmental stress cracking, stabilizer migration resistance,and degree of
4、 crosslinking. Methods of marking are also given.1.2 The text of this specification references notes, footnotes,and appendixes which provide explanatory material. Thesenotes and footnotes (excluding those in tables and figures) shallnot be considered as requirements of the specification.1.3 The valu
5、es stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.4 The following safety hazards caveat pertains only to thetest methods portion, Section 7, of this specification: Thisstandard does not purport to address all of the safety conc
6、erns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics f
7、or TestingD 792 Test Methods for Density and Specific Gravity (Rela-tive Density) of Plastics by DisplacementD 1505 Test Method for Density of Plastics by the Density-Gradient TechniqueD 1598 Test Method for Time-to-Failure of Plastic PipeUnder Constant Internal PressureD 1599 Test Method for Resist
8、ance to Short-Time Hydrau-lic Pressure of Plastic Pipe, Tubing, and FittingsD 1600 Terminology for Abbreviated Terms Relating toPlasticsD 1898 Practice for Sampling of Plastics3D 2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD 2765 Test Methods for Determination of G
9、el Content andSwell Ratio of Crosslinked Ethylene PlasticsD 2837 Test Method for Obtaining Hydrostatic DesignBasis for Thermoplastic Pipe Materials or Pressure DesignBasis for Thermoplastic Pipe ProductsD 3895 Test Method for Oxidative-Induction Time of Poly-olefins by Differential Scanning Calorime
10、tryF 412 Terminology Relating to Plastic Piping SystemsF 2023 Test Method for Evaluating the Oxidative Resis-tance of Crosslinked Polyethylene (PEX) Tubing andSystems to Hot Chlorinated Water2.2 ANSI Standard:B36.10 Standards Dimensions of Steel Pipe (IPS)42.3 Federal Standard:FED-STD-123 Marking fo
11、r Shipment (Civil Agencies)52.4 Military Standard:MIL-STD-129 Marking for Shipment and Storage52.5 NSF Standard:NSF 14 for Plastic Piping Components and Related Mate-rials62.6 ISO Standard:4ISO R 161-1690 Pipes of Plastic Materials for the Transportof Fluids (Outside Diameters and Nominal Pressures)
12、 Part1, Metric Series2.7 PPI Standard:7PPI TR-4 PPI Listing of Hydrostatic Design Basis (HDB),Strength Design Basis (SDB), Pressure Design Basis(PDB) and Minimum Required Strength (MRS) Ratings1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the dir
13、ect responsibility of Subcommittee F17.26 on OlefinBased Pipe.Current edition approved Dec. 15, 2006. Published January 2007. Originallyapproved in 1984. Last previous edition approved 2005 as F 876 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Serv
14、ice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.5Available from Standardization Documents
15、 Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.6Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd., AnnArbor, MI 48113-0140.7Plastics Pipe Institute (PPI), 105 Decker Court, Suite 825 Irving TX, 75062.http:/www.plasticpipe.org1Copyright A
16、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.for Thermoplastic Piping Materials or Pipe3. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology F 412, and abbreviations are in accordance with Ter-minology D 1600, unless ot
17、herwise specified. The abbreviationfor crosslinked polyethylene is PEX. Plastic tubing denotes aparticular diameter schedule of plastic pipe in which outsidediameter of the tubing is equal to the nominal size plus18 in.Plastic pipe outside diameter schedule conforms to ANSIB36.10.3.2 Definitions of
18、Terms Specific to This Standard:3.2.1 crosslinked polyethylene plasticsplastics preparedby crosslinking (curing) polyethylene compounds.3.2.2 hydrostatic design stress (HDS)the estimated maxi-mum tensile stress the material is capable of withstandingcontinuously with a high degree of certainty that
19、failure of thetube will not occur. This stress is circumferential when internalhydrostatic water pressure is applied. The HDS is equal to thehydrostatic design basis (HDB) times the design factor (DF)for water. For this standard, the design factor is equal to 0.50.HDS 5 HDB 3 DF5 HDB 3 0.50 for this
20、 standard!3.2.3 hydrostatic design basis (HDB)one of a series ofestablished stress values (specified in Test Method D 2837) fora plastic compound obtained by categorizing the long-termhydrostatic strength determined in accordance with TestMethod D 2837.3.2.4 pressure rating (PR)the estimated maximum
21、 waterpressure the tube is capable of withstanding continuously witha high degree of certainty that failure of the tube will not occur.3.2.5 relation between dimensions, hydrostatic designstress, and pressure ratingthe following expression, com-monly known as the ISO equation,8is used in this specif
22、icationto relate dimensions, hydrostatic design stress, and pressurerating:2S/P 5DO/t! 2 1 (1)or2S/P 5 R 2 1where:S = hydrostatic design stress, psi (or MPa),P = pressure rating, psi (or MPa),DO= average outside diameter, in. (or mm),t = minimum wall thickness, in. (or mm), andR = standard dimension
23、 ratio, SDR.3.2.6 standard dimension ratio (SDR)the ratio of outsidediameter to wall thickness. For PEX-tubing, it is calculated bydividing the average outside diameter of the tubing in inches orin millimetres by the minimum wall thickness in inches ormillimetres. If the wall thickness calculated by
24、 this formula isless than 0.070 in. (1.78 mm) it shall be arbitrarily increased to0.070 in. except for sizes18 in. and smaller. The SDR valuesshall be rounded to the nearest 0.5.3.2.7 standard thermoplastic tubing materials designationcodeThe tubing material designation code shall consist ofthe abbr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF8762006STANDARDSPECIFICATIONFORCROSSLINKEDPOLYETHYLENEPEXTUBING 交联 聚乙烯 PEX 标准规范 PDF

链接地址:http://www.mydoc123.com/p-537438.html