1、Designation: F721 81 (Reapproved 2014)F721 18 An American National StandardStandard Specification forGage Piping Assemblies1This standard is issued under the fixed designation F721; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, t
2、he year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers
3、 details of gage piping assemblies for pressure gages with optional provisions for additional gages,pressure switches, transmitters, and so forth, for use with steam, steam drains, feed water, condensate, fresh water, salt water,compressed air, fuel oil, and lubricating oil systems.1.2 The values st
4、ated in inch-pound units are to be regarded as the standard. The values given in parentheses are for informationonly. mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This international standard was developed in accordance with internati
5、onally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2A105/A105M
6、Specification for Carbon Steel Forgings for Piping ApplicationsA106/A106M Specification for Seamless Carbon Steel Pipe for High-Temperature ServiceA108 Specification for Steel Bar, Carbon and Alloy, Cold-FinishedA182/A182M Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Fo
7、rged Fittings, and Valves and Partsfor High-Temperature ServiceA276 Specification for Stainless Steel Bars and ShapesA335/A335M Specification for Seamless Ferritic Alloy-Steel Pipe for High-Temperature ServiceA576 Specification for Steel Bars, Carbon, Hot-Wrought, Special QualityB16/B16M Specificati
8、on for Free-Cutting Brass Rod, Bar and Shapes for Use in Screw MachinesB61 Specification for Steam or Valve Bronze CastingsB62 Specification for Composition Bronze or Ounce Metal CastingsB75 Specification for Seamless Copper TubeB124/B124M Specification for Copper and Copper Alloy Forging Rod, Bar,
9、and ShapesB453/B453M Specification for Copper-Zinc-Lead Alloy (Leaded-Brass) Rod, Bar, and ShapesB466/B466M Specification for Seamless Copper-Nickel Pipe and Tube2.2 ANSI Standards:3B16.11 Forged Steel Fittings, Socket Weld, and ThreadedB16.15 Cast Bronze Threaded Fittings2.3 Federal Specifications:
10、SAE International:4QQ-S-637 Steel Bar, Carbon, Cold Finished (Standard Quality, Free Machining)QQ-S-763AMS-QQ-S-763 Steel Steel, Corrosion Resistant, Bars, Wire, Shapes, and Forgings, Corrosion-Resisting Forgings1 This specification is under the jurisdiction of ASTM Committee F25 on Ships and Marine
11、 Technology and is the direct responsibility of Subcommittee F25.11 onMachinery and Piping Systems.Current edition approved Aug. 1, 2014May 1, 2018. Published September 2014May 2018. Originally approved in 1981. Last previous edition approved in 20082014 asF721 81 (2008).(2014). DOI: 10.1520/F0721-8
12、1R14.10.1520/F0721-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from American National Stan
13、dards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.4 Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.SAE International (SAE),400 Commonwealth Dr., Warrendale, PA 15096, http:/www.sae.org.This docume
14、nt is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as ap
15、propriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. List of Assemblies3.1 This specification incorporates 13
16、 gage piping assemblies as described in Table 1.4. General Requirements and Guidelines4.1 Fig. 1 shows a typical piping assembly for bottom-connected gages and Fig. 2 a typical piping assembly for back-connectedgages.4.2 A siphon shall be used as shown in all gage applications for steam systems to m
17、aintain a protective water seal between thegage and the steam supply.4.3 Each assembly includes a test connection beyond the gage valve which consists of a tee with a 14-in. NPT threaded plugin the branch. The plug is removable for the purpose of installing a test gage for calibration. As an alterna
18、tive, a gage valve thatincorporates a built-in test connection integral with the valve may be substituted for the gage valve and test tee.4.4 Root connections should be kept to a minimum by connecting other instruments at the tee between the root and gage valves.There is no limit to the number of de
19、ad-end-type instruments that can be served from a single root connection. However, eachinstrument should have its own shutoff valve and, if desired, a test tee may be fitted at each instrument.4.5 Two shutoff valves are generally used in each assembly, a root valve and a gage cutout valve. The gage
20、valve may beeliminated and a single shutoff valve may serve as both a root and gage valve provided the gage is within 6 ft (1.8 m) of the rootconnection and readily accessible and the single shutoff valve is fitted within 12 in. (300 mm) of the root connection.4.6 Pulsation dampeners are shown for c
21、ertain assemblies between the test tee and gage and should be used in other assembliesin which the gage may be subjected to pulsating pressures, as from a reciprocating pump, air compressor, quick-acting solenoidvalves, and high-frequency vibrations of high-pressure feed pumps.4.7 Isolation devices
22、(diaphragm seals) should be installed where system fluid viscosity and fuel isolation is a consideration.TABLE 1 Gage Piping AssembliesA,BAssemblyNo. ServiceMaximum Pressure,psi (kPa)Maximum Temperature,F (C)1 Superheated steam 1125 (7757) 960 (516)2 High-pressure desuperheated steam and high-pressu
23、re extractions 1100 (7584) 580 (304)3 Low-pressure extractions, gland seal, auxiliary exhaust, and 150-psig (1034-MPa)steam900 (6205) 563 (295)4 Low-pressure steam 125 (861) 353 (178)5 Boiler feed discharge 1500 (10 342) 450 (232)6 Feed suction and condensate 165 (1138) 300 (149)7 Compressed air abo
24、ve 165 psi (1.14 MPa) 900 (6205) 563 (295)8 Compressed air 165 (1138) 300 (149)9 Fresh and potable water 200 (1379) 150 (66)10 Main and auxiliary salt water circulating, salt water service, and wet firemain 200 (1379) 150 (66)11 Dry firemain and deck washdown 200 (1379) 150 (66)12 Fuel oil and lube
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF7212018STANDARDSPECIFICATIONFORGAGEPIPINGASSEMBLIES 仪表 管道 组件 标准规范 PDF

链接地址:http://www.mydoc123.com/p-537168.html