ASTM F567-2011 Standard Practice for Installation of Chain-Link Fence《链环栅栏安装标准操作规程》.pdf
《ASTM F567-2011 Standard Practice for Installation of Chain-Link Fence《链环栅栏安装标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F567-2011 Standard Practice for Installation of Chain-Link Fence《链环栅栏安装标准操作规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:F56707 Designation: F567 11Standard Practice forInstallation of Chain-Link Fence1This standard is issued under the fixed designation F567; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A num
2、ber in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the installation procedure for chain-link fence.1.2 This practice is intended primarily to guide those responsible fo
3、r or concerned with the installation of chain-link fence.1.3 This practice does not intend to preclude any practice that has proven equal to or given better performance under varyingconditions, that is, location, weather, intended use, materials, etc.1.41.4 The values stated in inch-pound units are
4、to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibili
5、tyof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For specific precautionary statements, see Section 13.2. Referenced Documents2.1 ASTM Standards:2F626 Specification for Fence FittingsF654 Specif
6、ication for Residential Chain Link Fence GatesF900 Specification for Industrial and Commercial Swing GatesF1184 Specification for Industrial and Commercial Horizontal Slide Gates3. Site Preparation3.1 The purchaser shall indicate the location of fence lines, gates, and terminal posts with suitable s
7、takes. Stake intervals shallnot exceed 500 ft 152.5 m(152.5 m) or line of sight.3.2 All underground utility locations, USC that is, under normal conditions the diameter shall be four times the largest cross section of the post up to a4 in. 101.5 mm(101.5 mm) outside diameter and three times for larg
8、er outside diameters. The depth shall be a minimum of 24in. 609.6 mm(609.6 mm) plus an additional 3 in. 76.2 mm(76.2 mm) for each 1-ft 305-mm(305-mm) increase in the fenceheight over 4 ft 1.22 m(1.22 m) to a maximum total of 60 in. 1525 mm(1525 mm) for a fence height up to 20 ft. 6.10 m. (6.10m).1Th
9、is practice is under the jurisdiction of ASTM Committee F14 on Fences and is the direct responsibility of Subcommittee F14.40 on Chain Link Fence and WireAccessories.Current edition approved JulyFeb. 1, 2007.2011. Published July 2007.February 2011. Originally approved in 1978. Last previous edition
10、approved in 20002007 asF567 - 007. DOI: 10.1520/F0567-07.10.1520/F0567-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on th
11、e ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users c
12、onsult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Dig or drill holes in the li
13、ne of the fence in accordance with 5.1. Forms are not necessary.5.3 Set posts in a vertical position, plumb and in line. Backfill concrete (2500 psi) 17.2 MPa(17.2 MPa) into the excavationand extend 2 in. 50 mm(50 mm) above grade. An alternative method is to stop footing 6 in. 152.4 mm(152.4 mm) bel
14、ow gradeto allow for cover with sod, black top, or other materials if the footings are not in an area subject to cathodic protection. In eithercase, crown the concrete at its top to shed water and slope a minimum of 2 in. 50.8 mm(50.8 mm) away from the post.5.4 The use of mechanical devices for the
15、setting of fence posts is acceptable under this practice, provided the mechanicalstrength in the ground is equal or superior to the strength developed by the concrete footing as recommended.5.5 When solid rock or concrete is encountered, without an overburden of soil, set posts in the solid rock or
16、concrete. The depthof the hole shall be three times the largest cross section of the posts. The diameter of the hole shall be12 in. 13 mm(13 mm)greater than the largest cross section of the post.5.6 The use of sleeves in order to leave voids in new concrete construction is recommended.5.7 Half-fill
17、the void with nonshrinkable hydraulic cement and force post to the bottom of the hole and plumb. Thoroughly workadditional grout into the hole so as to leave no voids. Crown the grout to shed water.5.8 Drive posts are to be driven by mechanical means to a minimum depth of 36 in. 914.4 mm(914.4 mm) o
18、r 6 in. 152.4mm(152.4 mm) greater than that called for in 5.1, for the height of fence.5.9 Where soil conditions are unstable or rock is encountered, the drive post embedment must be altered to maintain stability.The depth should be in keeping with standard fence construction practices for the local
19、 area or refer to 5.5.5.10 The post tops must be protected to prevent distortion of the exposed end. The use of a drive cap is recommended.5.11 Residential Swing Gate Posts:5.11.1 See Table 1.5.12 Industrial and Commercial Swing Gate Posts:5.12.1 See Table 2.5.13 Cantilever Slide Gate Posts (Specifi
20、cation F1184, Type II)Refer to Specification F1184, Type II Cantilever Slide Gates,for post setting requirements.5.14 Overhead Slide Gate Posts (Specification F1184, Type I)Refer to Specification F1184, Type I Overhead Slide Gates, forpost setting requirements.6. Terminal Post Bracing6.1 No braces a
21、re required on fabric 6 ft 1.83 m(1.83 m) high or less where the top rail is specified. On all fabric over 6 ft,braces are required. On fabric over 12 ft 3.66 m(3.66 m) in height, a center rail is required; regardless of height, all fencesinstalled without a top rail shall have braces on all termina
22、ls.6.2 Securely fasten diagonal braces to the terminal post and the adjacent line post or its footing or a footing of equal size. Thereshall be no more than a 50 angle between the brace and the ground. Securely fasten horizontal braces with truss rods to theadjacent line post and terminal posts.6.3
23、When the top rail is used, attach the brace at the halfway point of the terminal post above grade and, when the top rail isomitted, at the two-thirds point above grade.7. Top Rail and Tension Wire7.1 Support the top rail at each post so that a continuous brace from end to end of each stretch of fenc
24、e is formed. Securelyfasten the top rail to the terminal posts and join with sleeves or coupling to allow for expansion and contraction.7.2 When the top rail is omitted, stretch a tension wire from end to end of each stretch of fence at a height that will enable itto be fastened to the fabric within
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF5672011STANDARDPRACTICEFORINSTALLATIONOFCHAINLINKFENCE 链环 栅栏 安装 标准 操作规程 PDF

链接地址:http://www.mydoc123.com/p-536898.html