1、Designation: F 2005 05Standard Terminology forNickel-Titanium Shape Memory Alloys1This standard is issued under the fixed designation F 2005; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pa
2、rentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This terminology is a compilation of definitions of termsused in ASTM documents relating to nickel-titanium shapememory alloys used for medical de
3、vices. This terminologyincludes only those terms for whichASTM either has standardsor which are used inASTM standards for nickel-titanium shapememory alloys. It is not intended to be an all-inclusive list ofterms related to shape memory alloys.1.2 Definitions that are similar to those published by a
4、notherstandards body are identified with abbreviations of the name ofthat organization; for example, ICTAC is the InternationalConfederation for Thermal Analysis and Calorimetry.1.3 A definition is a single sentence with additional infor-mation included in a discussion. This standard is reviewedever
5、y five years, and the year of the last revision is appended.2. Referenced Documents2.1 ASTM Standards:2E7 Terminology Relating to MetallographyE 473 Terminology Relating to Thermal AnalysisF 2004 Test Method for Transformation Temperature ofNickel-Titanium Alloys by Thermal AnalysisF 2082 Test Metho
6、d for Determination of TransformationTemperature of Nickel-Titanium Shape Memory Alloys byBend and Free Recovery3. Terminologyactive austenite finish temperature, nterm used to denoteaustenite finish temperature of a finished wire, tube, orcomponent as determined by a bend and free recoverymethod ra
7、ther than by DSC.alloy phase, nin a shape memory alloy, the crystal structurestable at a particular temperature and stress.anneal, vto heat treat in order to remove the effect ofcold-working.austenite, nthe high temperature parent phase in Ni-Ti shapememory alloys with a B2 crystal structure. This p
8、hasetransforms to R-phase or martensite, or both, on cooling.austenite finish temperature (Af), nthe temperature atwhich the martensite to austenite transformation is com-pleted on heating in a single-stage transformation (Fig. 1)orthe temperature at which the R-phase to austenite transfor-mation is
9、 completed on heating in a two-stage transforma-tion (Fig. 2).austenite peak temperature (Ap), nthe temperature of theendothermic peak position on the differential scanningcalorimeter (DSC) curve upon heating for the martensite toaustenite transformation in a single-stage transformation(Fig. 1) or t
10、he temperature of the endothermic peak positionon the DSC curve upon heating for the R-phase to austenitetransformation in a two-stage transformation (Fig. 2).austenite start temperature (As), nthe temperature atwhich the martensite to austenite transformation begins onheating in a single-stage tran
11、sformation (Fig. 1)orthetemperature at which the R-phase to austenite transformationbegins on heating in a two-stage transformation (Fig. 2).bend and free recovery (BFR), na test method for deter-mining austenite transformation temperatures on heating.DISCUSSIONThe test involves cooling a wire or tu
12、be specimenbelow the Mftemperature, deforming the specimen in a controlledfashion, then heating through the austenite transformation. By measur-ing the shape memory response of the specimen Asand Af, tempera-tures can be determined. This test method is covered in Test MethodF 2082.differential scann
13、ing calorimeter (DSC), na device that iscapable of heating a test specimen and a reference at acontrolled rate and of automatically measuring the differencein heat flow between the specimen and the reference both tothe required sensitivity and precision.differential scanning calorimetry (DSC), na te
14、chnique inwhich the difference in heat flow into or out of a substanceand an inert reference is measured as a function of tempera-ture while the substance and the reference material aresubjected to a controlled temperature program. This testmethod, as it applies to Ni-Ti shape memory alloys, iscover
15、ed in Test Method F 2004. (E 473) (ICTAC) (1993)1This terminology is under the jurisdiction ofASTM Committee F04 on Medicaland Surgical Devices and is the direct responsibility of Subcommittee F04.12 onMetallurgical Materials.Current edition approved Oct. 1, 2005. Published October 2005. Originallya
16、pproved in 2000. Last previous edition approved in 2000 as F 2005 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
17、website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.free recovery, nunconstrained motion of a shape memoryalloy upon heating and transformation to austenite afterdeformation below the austenite phase.linear elasticity, nlinear re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20052005STANDARDTERMINOLOGYFORNICKELTITANIUMSHAPEMEMORYALLOYS 镍钛型 记忆 合金 标准 术语 PDF

链接地址:http://www.mydoc123.com/p-536266.html