ASTM F1913-2004(2010) Standard Specification for Vinyl Sheet Floor Covering Without Backing《无衬垫薄乙烯树脂地面铺层的标准规范》.pdf
《ASTM F1913-2004(2010) Standard Specification for Vinyl Sheet Floor Covering Without Backing《无衬垫薄乙烯树脂地面铺层的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1913-2004(2010) Standard Specification for Vinyl Sheet Floor Covering Without Backing《无衬垫薄乙烯树脂地面铺层的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1913 04 (Reapproved 2010)Standard Specification forVinyl Sheet Floor Covering Without Backing1This standard is issued under the fixed designation F1913; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers sheet floor covering having avinyl wear layer without backing. Products also may contain aclear
3、specialty performance top layer(s).1.2 This type of floor covering is intended for use incommercial and light commercial buildings. General informa-tion and performance characteristics, which determine service-ability and recommended use, are included in this specification.1.3 The values stated in i
4、nch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is
5、 theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F137 Test Method for Flexibility of Resilient FlooringMaterials with Cylindrical Ma
6、ndrel ApparatusF141 Terminology Relating to Resilient Floor CoveringsF386 Test Method for Thickness of Resilient FlooringMaterials Having Flat SurfacesF410 Test Method for Wear Layer Thickness of ResilientFloor Coverings by Optical MeasurementF925 Test Method for Resistance to Chemicals of Resilient
7、FlooringF970 Test Method for Static Load LimitF1514 Test Method for Measuring Heat Stability of Resil-ient Flooring by Color ChangeF1515 Test Method for Measuring Light Stability of Resil-ient Flooring by Color ChangeF1914 Test Methods for Short-Term Indentation and Re-sidual Indentation of Resilien
8、t Floor Covering2.2 ANSI/ASQC Standard:ANS/ASQC Z1.4 Sampling Procedures and Tables for In-spection by Attributes33. Terminology3.1 Definitions Terms used in this specification are de-fined in accordance with Terminology F141.3.2 Definitions of Terms Specific to This Standard:3.2.1 wear layer, nthe
9、portion of a resilient floor coveringthat contains the pattern effect.3.2.1.1 DiscussionThe wear layer thickness and totalthickness of through pattern unbacked sheet vinyl flooring arethe same. A clear specialty performance top layer may be usedto enhance specific properties and to protect the patte
10、rn effectand shall be counted as part of the wear layer. The wear layerdoes not include temporary finishes or maintenance coatings.4. Significance and Use4.1 The information in this specification is for use byspecifiers as a reference when selecting unbacked resilientsheet vinyl flooring for areas w
11、ithin commercial and lightcommercial buildings.5. Classification5.1 Sheet Vinyl floor covering shall conform to the follow-ing.5.1.1 The binder content of the PVC-pattern portion of thewear layer (vinyl resins, plasticizers, and stabilizers) shall be aminimum of 50 %. A clear specialty performance l
12、ayer(s) usedas the top layer is not described by binder limits.PVC Binder ContentMinimum % PVC Wear Layer Description50 % The material shall be a vinyl compound consistingof a blended composition of pigments stabilizedagainst heat and light deterioration. The design,color and pattern extends through
13、out the thicknessof the wear layer.5.1.1.1 All flooring may have a clear specialty performancetop layer(s) with an average minimum total thickness of 0.0004in. The specialty performance top layer(s) may consist of asingle layer or multiple layers, which do not delaminate under1This specification is
14、under the jurisdiction of ASTM Committee F06 onResilient Floor Coverings and is the direct responsibility of Subcommittee F06.80on Specifications.Current edition approved May 1, 2010. Published May 2010. Originallyapproved in 1998. Last previous edition approved in 2004 as F1913 - 04. DOI:10.1520/F1
15、913-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institu
16、te (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.normal use. Top layer(s) thinner than 0.0004 in. may be usedbut cannot be counted as part of the clear specia
17、lty perfor-mance top layer.5.1.2 The total thickness is the sum of the PVC wear layerand the clear specialty top layer(s). The total thickness averageminimum is 0.075 in. (1.9 mm).6. Ordering Information6.1 Sheet vinyl floor covering without backing shall beordered according to characteristics impor
18、tant to the purchaserfor the intended use as indicated by Table 1.6.2 Intended Use The following is a partial list providinggeneric guidance on typical applications of product use. Forspecific applications, refer to the manufacturers product rec-ommendations.6.2.1 LC (Light Commercial):6.2.1.1 Multi
19、-family DwellingCommon Areas.6.2.1.2 Hotel/Motel Guest Rooms.6.2.2 C (Commercial):6.2.2.1 Educational/Institutional.6.2.2.2 Hospital/Health Care.6.2.2.3 Retail/Mercantile.6.2.2.4 Office6.2.2.5 Hospitality.6.3 The purchaser may wish to specify the following items:6.3.1 Manufacturer,6.3.2 Style name a
20、nd number,6.3.3 Minimum roll width (see 9.1),6.3.4 Surface texture (see 7.1.3), and6.3.5 Variation in list of chemicals used to demonstratechemical resistance (see 12.7).7. Material7.1 Wear Layer:7.1.1 The wear layer shall have a vinyl plastic binder andmay include pigments, fillers, extenders, and
21、other ingredients;and shall be stabilized against heat and light deterioration (see12.8 and 12.9).7.1.2 The binder of the wear layer shall consist of one ormore vinyl resins, platicizers, and stabilizers. Each resin shallbe polyvinyl chloride or a copolymer of vinyl chloride not lessthan 85 % of whi
22、ch is vinyl chloride. The vinyl resin(s) shall benot less than 60 % by weight of the binder.7.1.3 The composition shall be uniform and extend through-out the full thickness of the pattern portion of the wear layer.7.2 Specialty Performance Top LayerA clear specialtyperformance top layer(s) of a prod
23、uct can be a PVC or nonPVC layer(s), which may constitute part of the total thicknessup to a maximum 0.005 in. and is not removable by normalmaintenance procedures.8. Physical Requirements8.1 Sheet vinyl floor covering shall meet the requirements inTable 2.9. Dimensions9.1 Common roll widths are 49-
24、in. (1.25-m), 59-in. (1.5-m),72-in. (1.83-m), and 78-in. (2-m) widths (minus 0 in.). Otherwidths may be available.9.2 The floor covering shall be furnished in a minimumaverage overall thickness of 0.075 in. (1.9 mm).10. Workmanship, Finish and Appearance10.1 Materials furnished under this specificat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF191320042010STANDARDSPECIFICATIONFORVINYLSHEETFLOORCOVERINGWITHOUTBACKING 衬垫 乙烯 树脂 地面 标准规范 PDF

链接地址:http://www.mydoc123.com/p-536019.html