1、Designation: F 1755M 96 (Reapproved 2007)An American National StandardStandard Specification forSolid State Bargraph Meters for Shipboard Use Metric1This standard is issued under the fixed designation F 1755M; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification provides the requirements for design,construction, performa
3、nce, and testing of solid state bargraph-type indicating meters.1.2 The solid state bargraph meters covered by this speci-fication are intended for use in shipboard applications ofelectrical measurement. This specification covers the require-ments and quality assurance provisions for solid state, pa
4、nel-type (edgewise), and rectangular switchboard-type instru-ments, which use light-emitting diodes (LEDs) for bargraphindication and optional digital displays.1.3 This specifications requirements may be invoked forspecialized measurement applications where another quantity,for example, position, we
5、ight, concentration of a trace elementin an atmosphere sample, and so forth, is converted to electricalenergy for display and measurement. Special dial markingsshall be specified for such cases.1.4 The values stated in metric units are to be regarded asthe standard. The values given in parentheses a
6、re for informa-tion only.2. Referenced Documents2.1 ASTM Standards:2B117 Practice for Operating Salt Spray (Fog) ApparatusD 3951 Practice for Commercial PackagingF 1166 Practice for Human Engineering Design for MarineSystems, Equipment, and Facilities2.2 Federal Specifications:TTE529 Enamel, Alkyd,
7、Semigloss, Low VOC Content32.3 Federal Standards:H28 Screw Thread Standards for Federal Services33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracy, nthe accuracy is a number that defines thelimit of errors expressed as a percentage of full-scale value.3.1.2 center-zero
8、meter, nmeter with display mode char-acterized by a sequentially illuminated string of LEDs startingat the center scale zero position and extending in eitherdirection from zero, proportional to the polarity and magnitudeof the input signal.3.1.3 dual bargraph display, ntwo completely indepen-dent ba
9、rgraph displays included in a single enclosure.3.1.4 end-scale value, nthe value of the actuating electri-cal quantity that corresponds to end scale indication. Whenzero is not at the end or at the electrical center of the scale, thehigher value is used. See Table 1.3.1.5 end-zero meter, nmeter with
10、 display mode charac-terized by a sequentially illuminated string of LEDs startingfrom a zero point, normally at the left for switchboard-stylemeters or horizontally installed edgewise meters, or the bottomof vertically installed edgewise meters, that extends in thedirection of full-scale value.3.1.
11、6 full-scale value, nfull-scale value is the largestvalue of the actuating electrical quantity, which can be indi-cated on the scale. For instruments with zero between the endsof the scale, the full-scale value is the arithmetic sum of thevalues of the actuating electrical quantity corresponding to
12、thetwo ends of the scale.3.1.7 response time, nthe response time is the timerequired for the indicating means to display a new value aftera step change has occurred in the measured quantity to a newconstant value.3.1.8 scale division, na scale division is the incrementbetween the centers of two cons
13、ecutive scale marks. Thenumber of scale marks is one more than the number of scaledivisions. For example, 10 scale divisions require 11 scalemarks.3.1.8.1 linear scale divisions, nlinear scale divisions arescale divisions that are spaced an equal distance apart and ofthe same value, for example, sca
14、le divisions spaced 5 A aparton a 100A meter.1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand Marine Technology and is the direct responsibility of Subcommittee F25.10 onElectrical.Current edition approved May 1, 2007. Published June 2007. Originallyapproved in 1996. L
15、ast previous edition approved in 2002 as F 1755M - 96(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3
16、Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 191115098, ATTN: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.8.2 nonlinear scale divisions, nnonlinear scale divi
17、-sions are scale divisions of the same value spaced an unequaldistance apart.3.1.9 scale length, nthe scale length is the length of thepath described by the pattern of the LEDs in moving from oneend of the scale to the other. For multiple scale meters, thelongest scale shall be used to determine the
18、 scale length.3.1.10 scale visibility, nscale visibility is the maximumhorizontal or vertical viewing angle measured from a linenormal to the scale from which all scale marks and arcs, but notnecessarily all markings, may be seen.4. Classification4.1 ClassificationBargraph meters covered in this spe
19、ci-fication shall be classified by type and style as specified in4.2-4.3.4.2 TypeThe type designation defines the physical con-figuration of the meter and the scale.4.2.1 Rectangular/switchboard-type meters present angulardisplays from 90 to 270 scale for the measured parameter(s).Fig. 1 provides ty
20、pical dimensional and mounting data forrectangular/switchboard-type meters.4.2.2 Edgewise/panel-type meters present linear displaysfor measured parameters. Fig. 2 provides typical dimensionaland mounting data for edgewise type meters.4.2.2.1 Orientation of MeterFor edgewise/panel-typemeters, the sca
21、le marking shall be specified either for a verticalor horizontal mounting condition.4.3 StyleThe style designation defines the meters displayattributes as follows:4.3.1 Bargraph DisplayThe bargraph display shall consistof light-emitting diode (LED) elements that illuminate toproduce a bar image prop
22、ortional to the input signal. Thedisplay designation defines whether the meter has single ordual bargraph displays.4.3.2 Digital DisplayThe digital display designation de-fines the number of digits in the digital display as follows:4.3.2.1 3-digit display.4.3.2.2 312-digit display.4.3.2.3 4-digit di
23、splay.4.3.2.4 412-digit display4.3.2.5 No digital display.5. Ordering Information5.1 Purchase orders or inquiries for bargraph meters of thisspecification shall specify the following:5.1.1 Title, date, and year of this specification.5.1.2 Quantity.5.1.3 Type and for edgewise meter, the orientation (
24、see 4.2).5.1.4 Style of display (single or dual, digital display) (see4.3).5.1.5 Window type (plastic or shatterproof glass) (see 7.5).5.1.6 Dial colors (see 7.9.1.1).5.1.7 Range(s) (see 7.9.2).5.1.8 Power supply voltage (see 8.1.1).5.1.9 Signal input (analog or digital) (see 8.1.2).5.1.10 Color(s)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF1755M19962007STANDARDSPECIFICATIONFORSOLIDSTATEBARGRAPHMETERSFORSHIPBOARDUSEMETRIC 固态 条形 仪表 标准规范

链接地址:http://www.mydoc123.com/p-535564.html