ASTM F119-1982(2015) Standard Test Method for Rate of Grease Penetration of Flexible Barrier Materials (Rapid Method)《软质密封材料润滑脂渗透率的标准试验方法 (快速法)》.pdf
《ASTM F119-1982(2015) Standard Test Method for Rate of Grease Penetration of Flexible Barrier Materials (Rapid Method)《软质密封材料润滑脂渗透率的标准试验方法 (快速法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM F119-1982(2015) Standard Test Method for Rate of Grease Penetration of Flexible Barrier Materials (Rapid Method)《软质密封材料润滑脂渗透率的标准试验方法 (快速法)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F119 82 (Reapproved 2015)Standard Test Method forRate of Grease Penetration of Flexible Barrier Materials(Rapid Method)1This standard is issued under the fixed designation F119; the number immediately following the designation indicates the year of originaladoption or, in the case of re
2、vision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test method
3、 provides standard conditions for deter-mining the rate of grease penetration of flexible barriermaterials. Pinholes, which can be measured by a separate test,will increase the rate of grease penetration as determined bythis test method.1.2 The values stated in SI units are to be regarded asstandard
4、. The values given in parentheses are for informationonly.1.3 This standard does not purport to address the safetyconcerns associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory l
5、imita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D374 Test Methods for Thickness of Solid Electrical Insu-lation (Withdrawn 2013)3D618 Practice for Conditioning Plastics for TestingD1898 Practice for Sampling of Plastics (Withdrawn 1998)32.2 TAPPI Standard:TAPPI T465 sm-52 Creasin
6、g of Paper for Water VaporPermeability Tests43. Summary of Test Method3.1 Flexible barrier materials, uncreased or creased by astandard procedure, are exposed on one side to grease con-tained in a weighted cotton patch. The time required to show avisual change caused by wetting (reduction in light s
7、cattering)of a ground-glass back-up plate is measured.4. Significance and Use4.1 This test method is valuable in the development andselection of flexible barrier materials suited for use as greasebarriers.4.2 The test is rapid in comparison with other methodsbecause of the extremely small quantity o
8、f oil required fordetection (about 6 g). The actual time to failure is a multipleof the values obtained by this test method. When permeation isthrough an absorbent structure such as kraft paper coated withpolyethylene, the failure times will be longer and variable,depending on the variation in poros
9、ity and thickness of thestructure.5. Apparatus5.1 Backing Plates, ground-glass, 50 by 50 by 3-mm (2 by2by18-in.), very fine grind on one side only.NOTE 1The ground-glass backing plates may be prepared from 2 by2-in. squares of18-in. plate glass by lightly grinding the surface with asilicon carbide a
10、brasive as follows: Place a piece of plate glass approxi-mately 1ft square on a flat surface. Mix some abrasive and water in smallquantities to make a fairly uniform paste. Place one of the 2-in. squares ofplate glass face down in the abrasive paste, and rotate it in a figure eightmovement with the
11、finger tips using the slightest amount of pressure.When the paste gets too heavy, remove the plate glass square from the bedand wash it to remove all traces of abrasive. Add more water to the thickabrasive paste on the bed. (If necessary, add small amounts of abrasive.)Continue the process until a u
12、niform and light overall etch is present onthe face of the square. When a uniform etch has been obtained, wash thesquare thoroughly to remove all traces of abrasive and pat dry with lenstissue.5.2 Weights, 50-g, 20 mm (0.75 in.) in diameter at the base.5.3 Patches, rifle cleaning, cotton flannel.5.4
13、 Medicine dropper.5.5 Forced-Circulation Oven, designed to maintain a testtemperature of 40 or 60C within 61C.1This test method is under the jurisdiction ofASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.10 onPermeation.Current edition approved Ju
14、ne 1, 2015. Published September 2015. Originallyapproved in 1970. Last previous edition approved in 2008 as F119 82 (2008).DOI: 10.1520/F0119-82R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandar
15、ds volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from Technical Association of the Pulp and Paper Industry (TAPPI),15 Technology Parkway South, Norcross, GA 30092, htt
16、p:/www.tappi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.6 Creasing Surface, consisting of a flat rectangular plate(for example, a piece of machined metal plate about 10 mmthick or a piece of plate glass) with a width at lea
17、st 75 mm (3in.) on all sides.5.7 Creasing Platen, consisting of a 5.5-kg (12-lb) squaremetal bar with 65-mm (2.5-in.) sides and a flat base.NOTE 2The developers of this method believe that a standard creaseis easier to obtain with a flat platen than with a roller. The weight of theplaten was selecte
18、d to conform to the weight loading per inch of crease inTAPPI T465 sm-52.5.8 Flat Strip of wood or metal to give the specimen apreliminary light crease.5.9 Thickness Measuring Device, capable of measuringthickness of specimens in compliance with Test MethodsD374.6. Reagents6.1 Animal Oil (lard).6.2
19、Mineral Oil.6.3 Vegetable Oil.6.4 Other reagents, such as butter, tallow, and oils. Thesemay be substituted for standard reagents listed above tosimulate actual end-use conditions. Standard reagents are,however, recommended for purposes of interlaboratory com-parisons.7. Sampling, Test Specimens, an
20、d Test Unit7.1 No single procedure for sampling is adequate for allsituations. Sampling, however, should be designed to providethe desired result in each situation. Therefore, Practice D1898is recommended as a guide in designing appropriate samplingprocedures for the purposes at hand.7.2 Flat Specim
21、enCut a minimum of three test specimens60 by 60 mm (238 by 238 in.) from each sample afterconditioning at least 40 h at 23 6 2C and 50 6 5 % relativehumidity. Measure the thickness of each specimen in fiveequally spaced positions as described in Test Methods D374 tothree significant figures, or to 0
22、.00025 mm (0.01 mil) whenthree significant digits cannot be obtained. Record the mea-surements.7.3 Crease TestPrepare a minimum of six test specimensas described in 7.2. Fold three specimens with top side up andthree specimens with bottom side up. Fold through the centerparallel to one side and pres
23、s a flat strip of wood or metal downon the fold to give the specimen a preliminary light crease. Tiltthe 5.5-kg (12-lb) creasing platen and slip the folded specimenunder it and parallel to its edge, until the fold lies at the centerof gravity of the platen. Gently lower the platen and let it reston
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF11919822015STANDARDTESTMETHODFORRATEOFGREASEPENETRATIONOFFLEXIBLEBARRIERMATERIALSRAPIDMETHOD 密封材料

链接地址:http://www.mydoc123.com/p-532420.html