ASTM E2964-2014e1 Standard Test Method for Measurement of the Normalized Insertion Loss of Doors《测量门的标准化插入损耗的标准试验方法》.pdf
《ASTM E2964-2014e1 Standard Test Method for Measurement of the Normalized Insertion Loss of Doors《测量门的标准化插入损耗的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2964-2014e1 Standard Test Method for Measurement of the Normalized Insertion Loss of Doors《测量门的标准化插入损耗的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2964 141Standard Test Method forMeasurement of the Normalized Insertion Loss of Doors1This standard is issued under the fixed designation E2964; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorially corrected 6.3 in February 2017.INTRODUCTIONThis test method is part of a set of standards for evaluating the sound-insulating
3、 properties ofbuilding elements and the sound isolation between spaces. It is designed to measure the field soundisolation performance of doors. Others in the set cover the airborne sound transmission loss of anisolated partition element in a controlled laboratory environment (Test Method E90), fiel
4、d measure-ments of the sound isolation between rooms in buildings (Test Method E336), the laboratorymeasurement of impact sound transmission through floors (Test Method E492), the measurement ofimpact sound transmission in buildings (Test Method E1007), the measurement of sound transmissionthrough b
5、uilding facades and facade elements (Guide E966), and the measurement of soundtransmission through a common plenum between two rooms (Test Method E1414).1. Scope1.1 The sound insulation properties of a door are measuredin a laboratory as the sound transmission loss in accordancewith Test Method E90.
6、 Using those data single number ratingsound transmission class (STC) is assigned. In the field, therooms on one or both sides of a partition containing a door areoften either too small or too large and absorptive to allow theapparent transmission loss (ATL) of the partition-door assem-bly to be meas
7、ured. Even if that is not the case, the resultmeasured is the composite ATL of the partition including thedoor, and not that of the door itself. Test Method E336 actuallystates that it is impossible to measure the ATL of a portion ofa partition such as a door according to the procedures of thatstand
8、ard. This test method provides a method of evaluatingdoors in such cases using a normalized insertion loss with aresulting single number rating door transmission class, DTC.This method is intended primarily for hinged personnel doorswith latching mechanisms and is limited to door openings ofarea les
9、s than 6 m2. The flanking effects of surroundingstructure are reduced compared to E336 but not completelyeliminated. In a laboratory environment, the DTC is close to orequal to the STC of the door, but in the field results less thanthe laboratory STC should be expected.1.2 The values stated in SI un
10、its are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pra
11、ctices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and EnvironmentalAcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions andElementsE3
12、36 Test Method for Measurement of Airborne SoundAttenuation between Rooms in BuildingsE413 Classification for Rating Sound InsulationE492 Test Method for Laboratory Measurement of ImpactSound Transmission Through Floor-Ceiling AssembliesUsing the Tapping MachineE966 Guide for Field Measurements of A
13、irborne SoundAttenuation of Building Facades and Facade ElementsE1007 Test Method for Field Measurement of Tapping1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.03 on Sound Transmission.Curre
14、nt edition approved June 1, 2014. Published July 2014. DOI: 10.1520/E2964-14E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
15、onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theD
16、evelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support StructuresE1414 Test Method for Airborne Sound Attenuation B
17、e-tween Rooms Sharing a Common Ceiling Plenum2.2 ANSI Standards:3S1.4 Specification for Sound Level MetersS1.10 Pressure Calibration of Laboratory Standard PressureMicrophonesS1.11 Specification for Octave-Band and Fractional-Octave-Band Analog and Digital FiltersS1.40 Specification and Verification
18、 Procedures for SoundCalibrators2.3 IEC Standards:4IEC 60804 Specification for Integrating-Averaging SoundLevel MetersIEC 60942 ElectroacousticsSound Calibrators2.4 ISO Standard:5ISO 16283-1:2014 Acoustics - Field measurement of soundinsulation in buildings and of building elements - Part 1:Airborne
19、 sound insulation3. Terminology3.1 The following terms used in this test method havespecific meanings that are defined in Terminology C634:3.1.1 airborne sound; background noise; decay rate; decibel;diffuse sound field; field sound transmission class, FSTC; fieldtransmission loss, FTL; flanking tran
20、smission; pink noise;receiving room; self-noise; sound absorption; sound attenua-tion; sound insulation; sound isolation; sound pressure level;sound transmission loss, TL; source roomNOTE 1The unqualified term average sound pressure level in thisdocument means that sound pressure levels were average
21、d for specifiedperiods of time.3.2 Definitions of Terms Specific to This Standard:3.2.1 apparent transmission loss, ATL, nof a partitioninstalled in a building, in a specified frequency band isoperationally defined as:ATL 5 L12 L2110 logSSA2D(1)where:S = the area of the partition common to both sour
22、ce andreceiving rooms,A2= the sound absorption in the receiving room,L1= the source room average sound pressure level, andL2= the receiving room average sound pressure level result-ing from the combined effect of direct and flankingtransmission.3.2.1.1 DiscussionThroughout this test method, log ista
23、ken to mean log10, unless otherwise indicated.3.2.1.2 DiscussionThis definition attributes all the powertransmitted into the receiving room, by direct and flankingpaths, to the area of the partition common to both rooms. Ifflanking transmission is significant, the ATL will be less thanthe TL for the
24、 partition. Apparent transmission loss (ATL) isequivalent in meaning to apparent sound reduction index(ASRI) used by ISO 16283-1:2014.3.2.2 direct transmission, nsound that travels between asource and a receiving room only through the common(separating) building element.3.2.3 door transmission class
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME29642014E1STANDARDTESTMETHODFORMEASUREMENTOFTHENORMALIZEDINSERTIONLOSSOFDOORS 测量 标准化 插入损耗 标准 试验

链接地址:http://www.mydoc123.com/p-532174.html