ASTM E2964-2014 Standard Test Method for Measurement of the Normalized Insertion Loss of Doors《测定门的归一化插入损耗的标准试验方法》.pdf
《ASTM E2964-2014 Standard Test Method for Measurement of the Normalized Insertion Loss of Doors《测定门的归一化插入损耗的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2964-2014 Standard Test Method for Measurement of the Normalized Insertion Loss of Doors《测定门的归一化插入损耗的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2964 14Standard Test Method forMeasurement of the Normalized Insertion Loss of Doors1This standard is issued under the fixed designation E2964; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method is part of a set of standards for evaluating the sound-insulating properties ofbuilding elements and the sound iso
3、lation between spaces. It is designed to measure the field soundisolation performance of doors. Others in the set cover the airborne sound transmission loss of anisolated partition element in a controlled laboratory environment (Test Method E90), field measure-ments of the sound isolation between ro
4、oms in buildings (Test Method E336), the laboratorymeasurement of impact sound transmission through floors (Test Method E492), the measurement ofimpact sound transmission in buildings (Test Method E1007), the measurement of sound transmissionthrough building facades and facade elements (Guide E966),
5、 and the measurement of soundtransmission through a common plenum between two rooms (Test Method E1414).1. Scope1.1 The sound insulation properties of a door are measuredin a laboratory as the sound transmission loss in accordancewith Test Method E90. Using those data single number ratingsound trans
6、mission class (STC) is assigned. In the field, therooms on one or both sides of a partition containing a door areoften either too small or too large and absorptive to allow theapparent transmission loss (ATL) of the partition-door assem-bly to be measured. Even if that is not the case, the resultmea
7、sured is the composite ATL of the partition including thedoor, and not that of the door itself. Test Method E336 actuallystates that it is impossible to measure the ATL of a portion ofa partition such as a door according to the procedures of thatstandard. This test method provides a method of evalua
8、tingdoors in such cases using a normalized insertion loss with aresulting single number rating door transmission class, DTC.This method is intended primarily for hinged personnel doorswith latching mechanisms and is limited to door openings ofarea less than 6 m2. The flanking effects of surroundings
9、tructure are reduced compared to E336 but not completelyeliminated. In a laboratory environment, the DTC is close to orequal to the STC of the door, but in the field results less thanthe laboratory STC should be expected.1.2 The values stated in SI units are to be regarded asstandard. No other units
10、 of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regula
11、tory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and EnvironmentalAcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions andElementsE336 Test Method for Measurement of Airborne SoundA
12、ttenuation between Rooms in BuildingsE413 Classification for Rating Sound InsulationE492 Test Method for Laboratory Measurement of ImpactSound Transmission Through Floor-Ceiling AssembliesUsing the Tapping MachineE966 Guide for Field Measurements of Airborne SoundAttenuation of Building Facades and
13、Facade ElementsE1007 Test Method for Field Measurement of TappingMachine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support StructuresE1414 Test Method for Airborne Sound Attenuation Be-tween Rooms Sharing a Common Ceiling Plenum1This test method is under the jurisdict
14、ion ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.03 on Sound Transmission.Current edition approved June 1, 2014. Published July 2014. DOI: 10.1520/E2964-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orconta
15、ct ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.2 ANSI Standards:3S1.4
16、 Specification for Sound Level MetersS1.10 Pressure Calibration of Laboratory Standard PressureMicrophonesS1.11 Specification for Octave-Band and Fractional-Octave-Band Analog and Digital FiltersS1.40 Specification and Verification Procedures for SoundCalibrators2.3 IEC Standards:4IEC 60804 Specific
17、ation for Integrating-Averaging SoundLevel MetersIEC 60942 ElectroacousticsSound Calibrators2.4 ISO Standard:5ISO 16283-1:2014 Acoustics - Field measurement of soundinsulation in buildings and of building elements - Part 1:Airborne sound insulation3. Terminology3.1 The following terms used in this t
18、est method havespecific meanings that are defined in Terminology C634:3.1.1 airborne sound; background noise; decay rate; decibel;diffuse sound field; field sound transmission class, FSTC; fieldtransmission loss, FTL; flanking transmission; pink noise;receiving room; self-noise; sound absorption; so
19、und attenua-tion; sound insulation; sound isolation; sound pressure level;sound transmission loss, TL; source roomNOTE 1The unqualified term average sound pressure level in thisdocument means that sound pressure levels were averaged for specifiedperiods of time.3.2 Definitions of Terms Specific to T
20、his Standard:3.2.1 apparent transmission loss, ATL, nof a partitioninstalled in a building, in a specified frequency band isoperationally defined as:ATL 5 L12 L2110 logSSA2D(1)where:S = the area of the partition common to both source andreceiving rooms,A2= the sound absorption in the receiving room,
21、L1= the source room average sound pressure level, andL2= the receiving room average sound pressure level result-ing from the combined effect of direct and flankingtransmission.3.2.1.1 DiscussionThroughout this test method, log istaken to mean log10, unless otherwise indicated.3.2.1.2 DiscussionThis
22、definition attributes all the powertransmitted into the receiving room, by direct and flankingpaths, to the area of the partition common to both rooms. Ifflanking transmission is significant, the ATL will be less thanthe TL for the partition. Apparent transmission loss (ATL) isequivalent in meaning
23、to apparent sound reduction index(ASRI) used by ISO 16283-1:2014.3.2.2 direct transmission, nsound that travels between asource and a receiving room only through the common(separating) building element.3.2.3 door transmission class, DTC, na single numberrating obtained by applying the classification
24、 procedure ofClassification E413 to normalized door insertion loss data.3.2.4 normalized door insertion loss, NDIL, nof a doorinstalled in a building in a specified frequency band isoperationally defined asNDIL 5Lrec open!2 Lrec closed!1Lsource closed!2 Lsource open!(2)when a sound source is operate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME29642014STANDARDTESTMETHODFORMEASUREMENTOFTHENORMALIZEDINSERTIONLOSSOFDOORS 测定 归一化 插入损耗 标准 试验 方法

链接地址:http://www.mydoc123.com/p-532173.html