ASTM E1388-2012 Standard Practice for Sampling of Headspace Vapors from Fire Debris Samples 《从火烧瓦砾样品中进行液上蒸气取样的标准操作规程》.pdf
《ASTM E1388-2012 Standard Practice for Sampling of Headspace Vapors from Fire Debris Samples 《从火烧瓦砾样品中进行液上蒸气取样的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1388-2012 Standard Practice for Sampling of Headspace Vapors from Fire Debris Samples 《从火烧瓦砾样品中进行液上蒸气取样的标准操作规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1388 12Standard Practice forSampling of Headspace Vapors from Fire Debris Samples1This standard is issued under the fixed designation E1388; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes the procedure for removingsmall quantities of ignitable liquid vapor from samples of firedebris by sampling th
3、e headspace of the debris container.1.2 Separation and concentration procedures are listed in thereferenced documents. (See Practices E1386, E1412, E1413,and E2154.)1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of th
4、e user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1386 Practice for Separation of Ignitable Liquid Residuesfrom Fire Debris Samples by Solvent ExtractionE14
5、12 Practice for Separation of Ignitable Liquid Residuesfrom Fire Debris Samples by Passive Headspace Concen-tration With Activated CharcoalE1413 Practice for Separation and Concentration of Ignit-able Liquid Residues from Fire Debris Samples by Dy-namic Headspace ConcentrationE1459 Guide for Physica
6、l Evidence Labeling and RelatedDocumentationE1492 Practice for Receiving, Documenting, Storing, andRetrieving Evidence in a Forensic Science LaboratoryE1618 Test Method for Ignitable Liquid Residues in Ex-tracts from Fire Debris Samples by Gas Chromatography-Mass SpectrometryE2154 Practice for Separ
7、ation and Concentration of Ignit-able Liquid Residues from Fire Debris Samples by PassiveHeadspace Concentration with Solid Phase Microextrac-tion (SPME)3. Summary of Practice3.1 The sample, preferably in its original container, isheated in order to volatilize any ignitable liquid residuespresent in
8、 the debris. After heating, the headspace is sampledand analyzed by gas chromatography-mass spectrometry.4. Significance and Use4.1 This procedure is particularly useful for screening firedebris samples to determine relative ignitable liquid concen-trations and possible ignitable liquid class prior
9、to extractionwith other techniques.4.2 This practice is useful when volatile oxygenated prod-ucts such as alcohols or lacquer thinners are suspected.4.3 This practice is the least sensitive of the sample prepa-ration techniques and may not detect quantities of less than 10L of an ignitable liquid.4.
10、4 Because this separation takes place in a closed con-tainer, the sample remains in approximately the same conditionin which it was submitted. Repeat and interlaboratory analysesare therefore possible.4.5 Due to variables in the debris sample condition prior toheadspace sampling, complete reproducib
11、ility of chromato-grams may be difficult to obtain.4.5.1 To obtain greater reproducibility, use one of theseparation procedures which results in a solution of theignitable liquid residue (see Practices E1386, E1412, andE1413).4.5.2 To obtain greater sensitivity for petroleum distillatesand oxygenate
12、d products, use solid phase microextraction. (SeePractice E2154.)4.6 High concentrations of highly volatile compounds mayswamp the headspace, inhibiting the recovery of less volatilecomponents.5. Apparatus5.1 Heating SystemAn oven, heating mantle or hot platedesigned to fit the evidence container.5.
13、2 Temperature Measuring DeviceA thermometer orthermocouple capable of measuring temperatures in the rangefrom 40 to 150C.5.3 A gas-tight syringe capable of reproducibility introduc-ing sample sizes in the range from 0.5 to 5 mL.5.4 Disposable 20 cc syringes.1This practice in under the jurisdiction o
14、f ASTM Committee E30 on ForensicSciences and is the direct responsibility of Subcommittee E30.01 on CriminalisticsCurrent edition approved Feb. 1, 2012. Published March 2012. Originallyapproved in 1990. Last previous edition approved in 2005 as E1388 05. DOI:10.1520/E1388-12.2For referenced ASTM sta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13882012STANDARDPRACTICEFORSAMPLINGOFHEADSPACEVAPORSFROMFIREDEBRISSAMPLES 火烧 瓦砾 样品 进行 蒸气 取样 标准 操作规程

链接地址:http://www.mydoc123.com/p-528596.html