ASTM E1273-1988(2003) Standard Specification for Color Coding of Reusable Laboratory Pipets《可重复使用的实验室移液管的色标》.pdf
《ASTM E1273-1988(2003) Standard Specification for Color Coding of Reusable Laboratory Pipets《可重复使用的实验室移液管的色标》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1273-1988(2003) Standard Specification for Color Coding of Reusable Laboratory Pipets《可重复使用的实验室移液管的色标》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1273 88 (Reapproved 2003)Standard Specification forColor Coding of Reusable Laboratory Pipets1This standard is issued under the fixed designation E 1273; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers a system of color coding forone-mark pipets for identification of nominal capacities, andfor
3、graduated pipets for identification of nominal capacities andunits of sub-division.1.2 This specification applies to one-mark and graduatedpipets of the nominal capacities listed in Table 1 and Table 2,respectively.NOTE 1Many pipets not covered by other ASTM standards areincluded in Table 1 and Tabl
4、e 2, in order, firstly, to ensure uniformity ofcolor coding as far as possible for non-standard as well as standard pipetsand, secondly, to reserve suitable codes for possible future standards forother types of pipet.2. Referenced Documents2.1 ASTM Standards:E 1157 Specification for the Sampling and
5、 Testing of Reus-able Laboratory Glassware23. Significance and Use3.1 The purpose of this specification is to ensure that if acolor code is used on pipets, all manufacturers will use thesame code; it is not intended as an encouragement of colorcoding if this is not required.4. Color Properties4.1 Co
6、dingThe color coding used on one-mark pipetsshall be in accordance with Table 1, and graduated pipets shallbe in accordance with Table 2.4.2 VariationsVariations in the enamels used in the meth-ods of application appropriate for pipets made from differenttypes of glass inevitably result in minor var
7、iations of color, andit is therefore not appropriate to specify closely the sevencolors listed in the tables.5. Marking Requirements5.1 The color code shall take the form of color bandsextending at least 150 around the circumference of the pipetand situated not more than 70 mm from the top of the pi
8、pet andnot less than 20 mm above the nearest graduation line.5.2 For a code consisting of a single band of color, the bandshall be 5 to 10 mm wide. For a code consisting of two bandsof color, each band shall be 3 to 5 mm wide and the two bandsshall be separated by a space of 2 to 3 mm. Color bands d
9、o nothave to be continuous but may be broken as long as they cover40 % of the circumference of the pipet.1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onGlass ApparatusCurrent edition approved Oct. 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME127319882003STANDARDSPECIFICATIONFORCOLORCODINGOFREUSABLELABORATORYPIPETS 重复使用 实验室 移液管 PDF

链接地址:http://www.mydoc123.com/p-528316.html