ASTM E1092-1991(2010) 1250 Standard Specification for Glass Micro Folin Pipet Disposable《易处置的微型(Folin)玻璃移液管的标准规范》.pdf
《ASTM E1092-1991(2010) 1250 Standard Specification for Glass Micro Folin Pipet Disposable《易处置的微型(Folin)玻璃移液管的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1092-1991(2010) 1250 Standard Specification for Glass Micro Folin Pipet Disposable《易处置的微型(Folin)玻璃移液管的标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1092 91 (Reapproved 2010)Standard Specification forGlass Micro Folin Pipet, Disposable1This standard is issued under the fixed designation E1092; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers a glass disposable micro Folinpipet suitable for use in micro techniques for estimation ofblood sugar b
3、y the Folin method.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 The following precautionary statement pertains only tothe test method portion, Section 8, of this specification. Thisstandard does not purport to address
4、 all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2E438 Specification
5、for Glasses in Laboratory Apparatus2.2 ISO Standard:1769 Laboratory GlasswarePipettesColor Coding33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracy, nthe expected distribution of mean vol-umes around the stated volume.3.1.2 coeffcient of variation, nthe expected distrib
6、utionof individual volumes around the mean volume.3.1.3 disposable, nmicro Folin pipets that are intended tobe used once only and then discarded.NOTE 1Such pipets will only be expected to provide their specifiedperformance during the original operation.4. Classification4.1 This specification covers
7、only one glass pipet as illus-trated in Fig. X1.1.5. Materials and Manufacture5.1 The pipet shall be made of borosilicate glass, Type 1,Class B, or soda lime glass, Type 2, in accordance withSpecification E438.6. Physical Properties6.1 DesignThe micro Folin pipet shall be made of onepiece constructi
8、on glass tubing that is straight and uniform borewith a point pulled on one end to the dimensions as specifiedin Fig. X1.1.6.2 DimensionsThe pipet shall be made of tubing with anoutside diameter (o.d.) of 2.5 6 0.1 mm with an insidediameter (i.d.) of 1.8 6 0.1 mm. The uniformity of the boreshall be
9、60.05 mm throughout the straight portion of the pipet.The pipet shall be 183 6 1 mm long with all dimensions andtolerances as shown in Fig. X1.1.6.3 CapacityThe pipet shall be calibrated “to contain”(T.C.) 0.1 and 0.2 mL at 20C. Marking shall be as specified in6.5.6.3.1 Accuracy (see 3.1.1)The accur
10、acy from stated vol-ume shall be 61.0 % for the 0.1 and 0.2-mL capacity and shallbe determined as specified in 8.1.6.3.2 Coeffcient of Variation (see 3.1.2)The coefficient ofvariation from stated volume for the 0.1 and 0.2-mL capacityshall not exceed 1.25 % and shall be determined as specified in8.1
11、.6.4 Graduation LinesThe pipet shall be calibrated andmarked with graduation lines at 0.1 and 0.2 mL from the tip ofthe pipet. The graduation lines shall be 0.3 6 0.1 mm and shallcompletely encircle the tube.1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus a
12、nd is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved Sept. 1, 2010. Published September 2010. Originallyapproved in 1986. Last previous edition approved in 2005 as E1092 91 (2005).DOI: 10.1520/E1092-91R10.2For referenced ASTM standards, visit the ASTM website,
13、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from International Organization for Standardization (ISO), 1, ch. dela Voie-Creuse, Case postale 56, CH-12
14、11, Geneva 20, Switzerland, http:/www.iso.ch.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.5 Pipet NomenclatureThe pipet shall be marked with0.1 and 0.2-mL markings slightly above the graduation lines.The pipet may be marked with
15、 the inscription TC 20C, or themanufacturers or vendors name or trademark, or both.6.6 Color CodingThe pipet shall be color coded forcapacity as specified in ISO Standard 1769 with an “orange”color band that is 6 6 2 mm wide and located 16 6 2 mm fromthe top of the pipet as shown in Fig. X1.1.6.7 Ma
16、rking PermanencyGraduation lines, inscriptions,and numerical markings on the pipet (other than the color codeband) shall be black in color. All markings may not be ofpermanent nature but must possess sufficient stability to endurenormal transportation and its expected one-time use and mustmeet the t
17、est requirements as specified in 8.5.6.8 Lot ControlA lot or control number shall be indicatedon the pipet container package. This lot or control number shallbe traceable to the origin and purchase order of raw materialglass tubing.7. Workmanship, Finish and Appearance7.1 The pipet shall be as free
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1092199120101250STANDARDSPECIFICATIONFORGLASSMICROFOLINPIPETDISPOSABLE 处置 微型 FOLIN 玻璃 移液管 标准规范 PDF

链接地址:http://www.mydoc123.com/p-527890.html