《ASTM D7903-2014 5195 Standard Practice for Determining the Capacity of Oxygen Removal Ion Exchange Cartridges《测定除氧离子交换柱能力的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7903-2014 5195 Standard Practice for Determining the Capacity of Oxygen Removal Ion Exchange Cartridges《测定除氧离子交换柱能力的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7903 14Standard Practice forDetermining the Capacity of Oxygen Removal Ion ExchangeCartridges1This standard is issued under the fixed designation D7903; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the determination of the perfor-mance of oxygen removal ion exchange resin cartridges in theregenerat
3、ed form when used for removing dissolved oxygenfrom water. The test can be used to determine the initialcapacity of unused cartridges or the remaining capacity of usedcartridges. In this case, performance is defined as oxygenremoval capacity (or throughput) to a defined endpoint.1.2 The values state
4、d in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and
5、health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D888 Test Methods for Dissolved Oxygen in WaterD1129 Terminology Relating to WaterD1193 Specification for Reagent Water3. Terminology3.1 DefinitionsFor definitions of t
6、erms related to water,refer to Terminology D1129.4. Summary of Practice4.1 This practice will evaluate the capacity of an oxygenremoval cartridge for water by running a test solution of knownoxygen content through a cartridge to a specified endpoint. Thevolume will enable a determination of the capa
7、city for thecartridge to remove dissolved oxygen in water.5. Significance and Use5.1 This practice can be used to evaluate unused oxygenremoval ion exchange cartridges for conformance to specifi-cations.5.2 This practice provides for the calculation of capacity interms of the volume of water treated
8、 to an end point level ofdissolved oxygen.5.3 The practice as written assumes that the oxygen removalion exchange resins in the cartridge are either partially or fullyregenerated. Regeneration of the resins is not part of thispractice.5.4 This practice provides for the calculation of capacity ona ca
9、rtridge basis.5.5 This practice may be used to test different size oxygenremoval resin cartridges. The flow rate of test water and thefrequency of sampling are varied to compensate for theapproximate volume of resin in the test cartridge.6. Apparatus6.1 Test assembly (Fig. 1), consisting of the foll
10、owing:6.1.1 Cartridge, and pressure vessel, if required. Connec-tions shall be provided at the top and the bottom for theadmission and removal of the exhausting solution as describedin 8.3, 8.4, and 8.5.6.1.2 Test solution tank. Adequate means of regulating andmeasuring flow through the cartridge sh
11、all be provided. If thetest flow rate (8.2) cannot be obtained by gravity feed, then apump should be used. Make sure all fittings, connections, andwetted pump portals are secure and tight to the atmosphere.6.1.3 Measuring oxygen levels of the water in the input andthe output of the test cartridge in
12、 accordance with Test MethodsD888. A continuous recorder is recommended.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the
13、American Chemical Society,1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.08 on Membranes and IonExchange Materials.Current edition approved Jan. 1, 2014. Published January 2014. DOI: 10.1520/D7903-14.2For referenced ASTM st
14、andards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
15、 PA 19428-2959. United States1where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Purity of WaterAll reference to water in this pract
16、iceshall be understood to mean Reagent Water Type I or IIconforming to Specification D1193, with the additional re-quirement that the silica concentration is less than 0.1 mg/L.7.3 Dissolved Oxygen Ion Exchange Test Water DPreparethe test water by filling tank with Reagent Water Type I or TypeII and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD790320145195STANDARDPRACTICEFORDETERMININGTHECAPACITYOFOXYGENREMOVALIONEXCHANGECARTRIDGES 测定 离子交换

链接地址:http://www.mydoc123.com/p-526502.html